Equilibria and Kinetics of Cr(VI) Reduction

심층 지하에서의 육가 크롬 환원

  • Published : 1993.09.01

Abstract

Reduction is one of the important mechanisrns in decreasing the amount of Cr(VI) in wastewater and this reaction is quite dependent on pH and temperature. Either soil organic materials, or a high inorganic salt concentration with elevated temperature and low pH will provide a good condition for the reduction of Cr(VI) to Cr(III) in deep well injection zones. Chromate reduction by soil organic materials and chloride ion in various environment conditions is investigated. Aquifer and aquitard formation samples have been obtained from a deep well in St. Bernard Parish, and St. Charles Parish, LA, U.S.A., respectively. For this study, pH ranging from -0.81 to 2.0, temperature $50^{\circ}C{\;}and{\;}70^{\circ}C$, and cliloride concentration 0 M, 0.26 M and 0.52 M are used to represent the actual conditions in deep well injection zones.

환원은 심층 지하처분되는 Cr(VI)의 양을 줄이는데 중요한 수단의 하나이다. 이 반응은 pH와 온도에 따라 민감하게 작용하며, 지하심층 처분장의 낮은 pH와 높은 온도는 토양 유기질, 높은 염소이온 농도와 더불어 Cr(VI)의 환원에 좋은 환경을 제공한다. 본 연구에서는 다양한 환경 조건에 따른 토양 유기질과 염소이온에 의한 Cr(VI)의 환원이 조사 되었다. aquifer와 aquitard 샘플은 각각 미국 루이지애나주 세인트 촬스군의 심층 처분장에서 채취되었다. 본 연구에서는 심층처분장을 대표하는 pH(-0.81~2.0), 온도($50^{\circ}C와{\;}70^{\circ}C$), 염소이온 농도(0, 0.26, 0.52 몰)를 이용하였다.

Keywords