Performance evaluation of brazed aluminum heat exchangers for a condenser in residential air-conditioning applications

가정용 공조기의 응축기 적용 알루미늄 열교환기의 성능 평가

  • 김만회 (삼성전자 기술총괄 생활시스템연구소) ;
  • 김권진 (삼성전자 기술총괄 생활시스템연구소)
  • Published : 1998.01.01

Abstract

The evaluation of aluminum flat tube and louver fin heat exchangers for a condenser in residential air-conditioning applications has been conducted. A series of tests for two-different brazed aluminum heat exchangers was performed and the results were compared with conventional fin and tube heat exchangers for residential air-conditioning system. Refrigerant charge amount for a window-system air-conditioner with the brazed aluminum condenser is decreased by 35% and the volume and material of heat exchanger can be reduced by 50% compared to the conventional fin and tube heat exchangers.

Keywords