Prediction of the ventilation performance in a kitchen with various locations of gas range and window

가스렌지와 창문위치에 따른 주방 배기성능 예측

  • Published : 2000.01.01

Abstract

This paper presents the predicted results by CFD technique of air flow and contaminant distribution in a full-scale kitchen opened to a living room, ventilated by a exhaust hood. To analyze the characteristics of the indoor environment, the concept of contaminant index was defined. In this study, the locations of the gas range and the window were chosen as the parameters to investigate the indoor environment. The values of the contaminant index for several layout of the gas range and the window were calculated and compared. When the gas range is installed along the wall with specified window location, its position in relation to the wall has unnoticed effect on contaminant infer. Once the location of the gas range is fixed, the indoor air quality may deteriorate by the proximity of the window to the gas range. This is due to the shorter distance that external fresh air must travel within the kitchen before it reaches the exhaust fan.

Keywords

References

  1. ASHRAE Trans. Part 2 Minimum-energy kitchen ventilation for quick service restaurants Smith, V. A.;Donald, J. D.
  2. ASHRAE Trans. Part 2 New threshold exhaust flow rates of capture and containment of cooling effluent Swierczyna, R. T.;Smih, V. A.;Ferdinand, J. D.
  3. ASHRAE Trans. Part 2 Flow Visualization in commercial kitchen ventilation research Schmid, F. P.;Smih, V. A.;Swierczyna, R. T.;Schliren
  4. ASHRAE Technical Data Bulletin v.8 no.4 Residential kitchen ventilation - a guide for the specifying engineer Wolbrink, D. W.;Sarnosky, J. R.
  5. ASHRAE Technical Data Bulletin v.8 no.4 Computational simulation of kitchen airflows with commercial hoods Kelso, R. M.;Wilkening, L. E.;Schaub, E. G.;Baker, A. J.
  6. Annex20 Air flow patterns within buildings, subtask1 summary report Room air and contaminant flow, evaluation of computational methods Lemaire, A. D.
  7. ASHRAE Trans. Part 2 Room air and contaminant distribution in mixing ventilation Heiselbelg, P.
  8. Ph.D. Dissertation, Dept. of Mechanical Eng. Dispersion of hydrogen in air in vented 3-D enclosures Shivdas, A.
  9. 공기조화 제3판 김효경