An Experimental Study on the Performance of a Liquid-Vapor Ejector with Water

액체-증기 이젝터의 성능에 관한 실험적 연구

  • Published : 2000.04.01

Abstract

In this study, the performance of five ejectors has been investigated with working fluids of water and water vapor. The diameters of nozzle and mixing tube of five ejectors were 1 and 1.5(ejector A), 1 and 2(ejector B), 1 and 2.5(ejector C), 1 and 3(ejector D), 2 and 4(ejector E) in millimeters. The length of the mixing tube was 8-10 times of its diameter. For each ejector, the ratio of mass flow rate of ejected water to that of entrained water vapor, $\mu$, was evaluated in terms of evaporator pressure, mass flow rate of ejected water, and water temperature. It was found that the performance of an ejector was not stable when the ratio of diameters was too small or too large(ejector A and D) and $\mu$ was almost the same for two ejectors with the same diameter ratio(ejector B and E). It was also found that $\mu$ increased almost linearly with an increase of evaporator pressure and the ratio $\mu$ increased as water temperature decreased. As expected, $\mu$ converged to zero as the water temperature approached the evaporator temperature. Finally, a non-dimensional correlation has been developed to predict$\mu$ terms of evaporator pressure and saturation pressure of ejected water.

Keywords

References

  1. VDI Forschungsheft 395 Ausgabe B Band 10 Berechnung von strahlapparaten Fluegel, G.
  2. Journal of the Institute of Energy v.68 Recent developments in the design theories and applications of ejectors-a review Sun, D.W.;Eames, I.E.
  3. British Chemical Engineering v.10 no.9 Efficiency and design of liquid-gas ejector Witte, J. H.
  4. The Canadian Journal of Chemical Engineering v.59 Momentum transfer in a horizontal multi-Jet liquid-gas ejector Biswas, M.N.;Mitra, A.K.
  5. The Canadian Journal of Chemical Engineering v.50 Momentum transfer in a jet ejector for absorption system Mitra, A.K.;Bhat, P.A.;Roy, A.N.
  6. Int. Absorption Heat Pump Conference ASME v.31 Heat and mass transfer in a jet ejector for absorption system Daltrophe, N.C.;Jelinek, M.
  7. International Journal of Energy Research v.22 Study on a solar-driven ejection absorption refrigeration cycle Wang, J.;Chen, G.;Jiang, H.
  8. Chemical Engineering Science v.52 no.11 Effect of the ejector configuration on the gas suction rate and gas hold-up in ejector loop reactors Havelka, P.