Analysis and Experiment on The Performance of an Autocascade Refrigeration System Using Carbon Dioxide As a Refrigerant

이산화탄소를 냉매로 사용하는 오토캐스케이드 냉동기의 성능에 관한 해석 및 실험

  • 김성구 (서울대학교 기계항공공학부) ;
  • 김민수 (서울대학교 기계항공공학부)
  • Published : 2001.05.01

Abstract

The purpose of this study is to investigate the performance of an autocascade refrigeration system by simulation and experiment using refrigerant mixtures of R744/134a and R744/290 as working fluid. Variations of mass flow rate of refrigerant, compressor work refrigeration capacity and COP with respect to mass fraction of R744/134a and R744/290 mixture were presented under different operating conditions. Performance test has been executed by ASRAE standard. Experimental results show as the composition of R744 in the refrigerant mixture increases, heating and coling capacity are enhanced, but COP trends to decrease. Experimental results are compared with those from the simulation.

Keywords

References

  1. Hydrocarbons-HighTech in Refrigeration Greenpeace
  2. ⅢR Commisssions B1, B2, E1 & E2, Applicatons for Natural Refrigerants v.3-6 Current Status of Natural Working Fluids in Refrigeration, A/C, and Heat Pump Systems Kruse,H.
  3. Int. J. Refrig v.16 A New, Efficient and Environmentally Benign System for Car Air-Conditioning Lorentzen, G.;Pettersen, J.
  4. Int. J. Refrig. v.18 no.3 The use of natural refrigerants: a complete solution to the CFC/HCFC predicament Lorentzen,G.
  5. Korean J. Air-Cond. Ref. Eng. v.11 Performance of Autocascade Refrigeration system Using Carbon Dioxide and R134a Park, S. N.;Kim, M. S.
  6. Refrigeration & Air condditoning(2nd ed.) Stoecker,W.F.;Jones,J.W.
  7. Int. J. Refrig v.15 no.2 A Simplified Cycle Simulation Model for the Performance Rating of Refrigerants and Refrigerant Mixtures Domanski, P.;McLinden, M.
  8. NIST Thermodynamic and Transport Properties of Refrigerants and Refrigerant Mixtures(Ver 6.0) McLinden,M.;Klein,S.;Lemmon,E.;Peskin,A.
  9. Industrial Refrigeration v.Ⅱ Stoecker,W.F.
  10. ASHRAE Standard 116-1983 Method of Testing for Seasonal Efficiency of Unitary Air-Conditioners and Heat Pump ASHRAE