DOI QR코드

DOI QR Code

Seismic Analysis of an Axial Blower Using a Commercial FEM Code

상용 유한요소해석 프로그램을 이용한 축류송풍기의 내진해석

  • 정진태 (한양대학교 기계공학과) ;
  • 임형빈 (한양대학교 대학원 정밀기계공학과) ;
  • 김강성 (한양대학교 대학원 정밀기계공학과) ;
  • 허진욱 (한양대학교 대학원 정밀기계공학과)
  • Published : 2002.03.01

Abstract

A seismic analysis is one of crucial design procedures of an axial blower used in nuclear power Plants. The blower should be operated even in ar emergency such as an earthquake. The blower should be designed in order to stand against an earthquake. For the seismic analysis, Ive perform the modal analysis and then evaluate the required response spectrum (PRS) from the given floor response spectrum (FRS). A finite element model of the blower is established by using a commercial FEM code of ANSYS. After the finite element modeling. the natural frequencies. the mode shapes and the participation factors are obtained from the modal analysis. The PRS is acquired by a numerical approach on the basis of the principle of mode superposition. We verify the structura safety of the axial blower and confirm the validity of the present seismic analysis results.

Keywords

References

  1. 한국소음진동학회지 v.9 no.3 원자력발전소(영광 5&6호기)용 공조기에 대한 내진검증 이준근;김진영;정필중;정정훈
  2. 대한기계학회 춘계학술대회 논문집 울진 원자력발전소 5&6 호기용 공기정화기에 대한 내진검증 이준근;김진영;정필중
  3. Modal Testing : Theory and Practice D. J. Ewins
  4. Analytical Methods in Vibrations Leonard Meirovitch
  5. Meirovitch Methods of Analytical Dynamics Leonard Meirovitch
  6. Theory of Vibration with Application(Fifth Edition) Willam T. Thomason;Marie Dillon Dahleh
  7. Ansys Dynamics;Users Guide for Revision 5.1 Ansys. Inc.

Cited by

  1. Seismic Evaluation of Structural Integrity of Main Cooling-Water Pump by Response Spectrum Analysis vol.34, pp.11, 2010, https://doi.org/10.3795/KSME-A.2010.34.11.1773