Analysis of Signal Transfer Characteristics of Implantable Middle Ear System using Acoustic Model

청각모델을 이용한 이식형 인공중이 시스템의 신호 전달 특성 해석

  • 송병섭 (경북대학교 센서기술연구소) ;
  • 조진호 (경북대학교 전자전기컴퓨터학과, 경북대학교 의과대학 의공학교실)
  • Published : 2002.06.01

Abstract

The IME(implantable middle ear) system is Promising due to its ability to free from sound feedback and Produce a good sound quality and intelligibility with low distortion even if it is operated with high gain for severe hearing impaired. The differential electromagnetic vibration transducer. which was developed for using in IME system and has two small magnets attached the same Pole facing in the coil. is not influenced by environmental external magnetic field. Besides, it has high vibration efficiency and good frequency response characteristics. In this Paper, using acoustic model of the transducer and ear model of normal Person. the signal transfer characteristics of the IME system are analyzed and investigated From the differences of the characteristics between normal ear and the IME system, it is Possible that design of the IME system that have the signal transfer characteristics similar to normal person's ear.

이식형 인공중이는 음질과 주파수 특성이 우수하며 기존의 공기전도형 보청기가 가지는 고이득에서의 왜곡과 음향 피이드백에 의한 링잉 현상을 해소할 수 있어 차세대 보청기로 주목받고 있다 특히 두 개의 영구자석을 같은 극기리 접착한 후 코일내부에 위치시킨 타동 전자 트랜스듀서 방식의 이식형 인공중이는 외부의 자기장에 대해 영향을 받지 않으며 진동효율이 높고 자석과 코일의 간격조정이 필요 없는 동시에 주파수 응답특성이 우수하다. 본 연구에서는 이식형 인공중이에 사용하위해 개발된 타동 전자 트랜스듀서의 음향 모델을 구현한 후 정상인의 귀의 청각 모델에 적용시켜 트랜스듀서를 통하여 내이로 전달되는 신호의 주파수 특성을 해석하였다. 해석된 결과를 정상인의 귀의 주파수 특성과 비교함으로써 인공중이를 사용할 경우와 정상인의 귀와의 신호전달 특성 차이를 조사하였고 이를 통하여 정상인의 청각특성에 가까운 신호를 전달시킬 수 있는 인공중이의 설계가 가능하도록 하였다.

Keywords

References

  1. The Otolaryngologic Clinics of North America v.28 The history and decelopment of the implantable hearing aid R.Goode;M.Rosenbaum;A.Maniglia
  2. The Otolaryngologic Clinics of North America v.28 no.1 Engineering principles of mechanical stimulation of the middle ear W.Ko;W.Zhu;A.Maniglia
  3. Trends in Amplification v.2 no.3 Current trends in implantable hearing aids A.Chasin https://doi.org/10.1177/108471389700200302
  4. Journal of Otolaryngology,Head Neck Surgery v.11 no.4 補聽器と 人工中耳 Richard L. Goode
  5. The American Journal of Otology v.20 Current status and Critical reflections on implantable hearing aids Richard L.Goode
  6. Ear.Nose and Throat Journal Acute Human trial of the fooating mass transducer Tjellstrom;C.Luetje
  7. American Journal of Otolarlyngology v.21 no.1 The effect of the floating mass transducer in hearing sensitibity F.Snik;W.Cremers https://doi.org/10.1016/S0196-0709(00)80111-8
  8. 대한의용생체공학회지 v.20 no.5 이식형 인공중이 시스템을 위한 차동 플로팅매스형 전자 트랜스듀서 송병섭;박재훈;윤영호;배상곤;채스표;김명남;이상흔;이건일;조진호
  9. Proceedings of the 22th Annual International Conference of the IEEE Engineering in Medicine and Biological Society v.4 Differential floating mass type vibration transducer for MEI System B.S.Song;J.H.Park;Y.H.Yoon;M.N.Kim;S.K.Park;S.H.Lee;J.H.Cho
  10. Fundamentals of noise and vibration analysis for engineers M.Norton
  11. Mechanical Vibrations S.Rao
  12. Handbook of Mathematical Psychology J.Zwislocki
  13. Journal of Acoustic Society of American v.104 no.3 Linear and nonlinear model of the human middle ear J.Pascal;A.Bourgeade https://doi.org/10.1121/1.424363
  14. Fundamentals of Acoustics L.Kinsler;A,Frey;A,Coppens;J.Sanders
  15. The Journal of the Acoustical Society of American v.34 Analysis of the middle-ear function PartⅠ:input impedance J.Zwislocki https://doi.org/10.1121/1.1918382
  16. The Journal of the Acoustical Society of American v.33 Mechanism of the middle ear Y.Onchi https://doi.org/10.1121/1.1908801
  17. The Journal of the Acoustical Society of American v.33 Network model of the middle ear A,Moller
  18. The Journal of the Acoustical Society of American v.35 Transfer function of the middle ear A,Moller https://doi.org/10.1121/1.1918742
  19. Journal of Sound vibration Development of an electroacoustic analogue model of the middle ear and acoustic reflex M.Lutman;A,Martin