Detection of Poliovirus in Water by Cell Culture and PCR Methods

세포배양법과 PCR 방법에 의한 물에서의 폴리오 바이러스 검출

  • 조연희 (충북대학교 자연과학대학 생명과학부) ;
  • 이찬희 (충북대학교 자연과학대학 생명과학부, 충북대학교 바이오연구소)
  • Published : 2002.09.01

Abstract

Poliovirus is a member of enterovirus which causes paralytic poliomyelitis, encephalitis and aseptic meningitis. Since poliovirus is spread by the fecal-oral route and poliovirus-contaminated water could be a potential threat for public health, detection of poliovirus in drinking water resource is important. Infectious poliovirus and poliovirus inactivated by heat or UV were used to test three detection methods such as cell culture method, reverse transcription-polymerase chain reaction (RT-PCR) and integrated cell culture (ICC)-PCR. Infectious poliovirus was detected by all three methods and ICC-PCR was the most sensitive and fast in detecting poliovirus. Inactivated polioviruses could not be detected by cell culture or ICC-PCR methods. On the other hand, heat- inactivated viruses could be detected by RT-PCR. Thus it is suggested that ICC-PCR method is the most sensitive and effective in detecting infectious polioviruses in water sample.

폴리오 바이러스는 전형적인 장관계 바이러스로 마비, 무균성 수막염, 뇌염 등을 유발한다. 폴리오 바이러스는 분변-구강 경로를 통해 전파되며, 오염된 물을 음용수로 사용할 시 공중 보건에 문제가 될 수 있으므로 먹는 물에서 폴리오 바이러스를 검출하는 것은 중요하다. 감염성이 있는 바이 러스와 불활성화(열처리와 자외선 처리)시킨 바이러스를 세포배양법, 역전사 중합효소 연쇄반응법(reverse transcription-polymerase chain reaction: RT-PCR)그리고 세포배양-중합효소 연쇄반응 통합법(integrated cell culture-PCR: ICC-PCR)으로 검출 실험을 했다. 감염성이 있는 폴리오 바이러스는 세 가지 방법으로 모두 검출이 되었으며, 이 중에서 바이러스를 검출하는데 ICC-PCR 방법이 가장 민감했다. 세포배양법은 적은 수의 바이러스를 검출하는데 약 2주의 긴 시간이 걸렸다. 열처리나 자외선 처리로 불활성화된 바이 러스는 세포배양과 ICC-PCR방법으로는 검출이 되지 않았다. 자외선 처리한 바이러스는 RT-PCR 방법으로 검출되지 않았으나 열처리한 바이러스는 검출되었다. RT-PCR 방법은 감염성 바이러스뿐 아니라 불활성화된 바이러스도 검출할 수 있으므로 감염성이 있는지 없는지를 구분할 수 없는 단점이 있다. 이와 같은 결과는 감염성 있는 바이러스를 가장 민감하고 효과적으로 검출하는 방법이 ICC-PCR 방법이라는 것을 제시하여 준다.

Keywords

References

  1. Kor. J. Microbiol. v.35 수계바이러스 검출에 PCR을 이용 하기 위한 효과적인 농축기법 이승훈;김상종
  2. Appl. Environ. Microbiol. v.59 Detection of enteroviruses in groundwater with the polymerase chain reaction Abbaszadegan, M.;M.S. Huber;C.P. Gerba;I.L. Pepper
  3. Appl. Environ. Microbiol. v.65 A strategy for detection of viruses in groundwater by PCR Abbaszadegan, M.;P. Stewart;M. LeChevallier
  4. Appl. Environ. Microbiol. v.59 Detection of enteric viruses in oysters by using the polymerase chain reaction Atmar, R.L.;T.G. Metcaf;F.H. Neill;M.K. Estes
  5. J. Clin. Microbiol. v.34 Rapid diagnosis of poliovirus infection by PCR amplification Chezzi C.
  6. Can. J. Microbiol. v.46 Detection of adenoviruses and enteroviruses in tap water and river water by reverse transcription multiplex PCR Cho, H.B.;S.H. Lee;J.C. Cho;S.J. Kim https://doi.org/10.1139/cjm-46-5-417
  7. Appl. Environ. Microbiol. v.61 Reverse transcription PCR to detect enteroviruses in surface water Gilgen, M.;B. Wegmuller;P. Burkhalter;H.P. Buhler;U. Muller;J. Luthy;U. Candrian
  8. J. Virol. Methods v.82 RT-PCR and chemiluminescent ELISA for detection of enteroviruses Greening, G.E.;L. Woodfield;G.D. Lewis https://doi.org/10.1016/S0166-0934(99)00098-1
  9. Appl. Environ. Microbiol. v.46 Inactivation of hepatitis A virus and indicator organisms in water by free chlorine residuals Grabow, W.O.;V. Gauss-Muller;O.W. Prozesky;F. Deinhard
  10. J. Am. Water Works Assoc. v.81 Detecting viruses in water Hurst, C.J.;W.H. Benton;R.E. Stetler https://doi.org/10.1002/j.1551-8833.1989.tb03273.x
  11. Appl. Environ. Microbiol. v.47 Detection of enteric viruses in treated drinking water Keswick, B.H.;C.P. Gerba;H.L. DuPont;J.B. Rose
  12. J. Appl. Microbiol. v.88 Influence of environmental factors on virus detection by RT-PCR and cell culture Lewis, G.D.;S.L. Molloy;G.E. Greening;J. Dawson https://doi.org/10.1046/j.1365-2672.2000.01008.x
  13. Appl. Environ. Microbiol. v.60 Cell culture and PCR determination of poliovirus inactivation by disinfectants Ma, J.;T.M. Straub;I.L Pepper;C.P. Gerba
  14. Appl. Environ. Microbiol. v.59 Survival of human immunodeficiency virus (HIV), HIV-infected lymphocytes and poliovirus in water Moore, B.E.
  15. Biologicals. v.24 Inactivation of hepatitis A and other enteroviruses during heat treatment (pasteurization) Nissen, E.;P. Konig;S.M. Feinstone;G. Pauli https://doi.org/10.1006/biol.1996.0048
  16. Can. J. Microbiol. v.33 Detection and quantitation of human enteric viruses in wastewaters: increased sensitivity using human immune serum globulin-immunoperoxidase assay on MA104 cells Payment, P.;M. Trudel https://doi.org/10.1139/m87-097
  17. Res. Microbiol. v.150 Nucleic acid extraction from polluted estuarine water for detection of viruses and bacteria by PCR and RT-PCR analysis Petit, F.;S. Craquelin;J. Guespin-Michel;C. Buffet-Janvresse https://doi.org/10.1016/S0923-2508(99)80031-X
  18. Appl. Environ. Microbiol. v.60 Detection of adenoviruses and enteroviruses in polluted waters by nested PCR amplification Puig, M.;J. Jofre;F. Lucena;A. Allard;G. Wadell;R. Girones
  19. Appl. Environ. Microbiol. v.62 Detection of infectious enteroviruses by an integrated cell culture-PCR procedure Reynolds, K.A.;C.P. Gerba;I.L. Pepper
  20. Can. J. Microbiol. v.47 ICC/PCR detection of enteroviruses and hepatitis A virus in environmental samples Reynolds, K.A.;C.P. Gerba;M. Abbaszadegan;I.L. Pepper https://doi.org/10.1139/cjm-47-2-153