Abstract

Because of the environmental problem during the pile driving, the use of low noise-vibration auger-drilled pilling is increasing to solve noise and vibration problem in pilling. In Korea, SIP (Soil-Cement Injected Precast Pile) method is mainly used as auger-drilled pilling. But, a proper bearing capacity evaluation formula has not been suggested, yet. To improve and supplement this situation, direct shear tests between SIP pile skin interface and soil were executed under various conditions. Through the analysis of test results, skin resistance characteristics of SIP were investigated thoroughly. Also, the maximum unit skin resistance capacity evaluation formulae on SM, SC soil was suggested.

건설공사에서 발생하는 환경문제에 대한 관심이 고조되는 가운데 기성 말뚝을 항타하는 과정에서 유발되는 소음, 진동문제를 해결하기 위해 저소음, 저진동 공법인 매입말뚝공법이 많이 적용되고 있다. 국내에서는 매입말뚝공법으로 SIP공법이 주로 사용되고 있다. 그러나 아직까지 SIP공법에 관한 합리적인 지지력 산정식이 제시되어있지 못한 실정이다. 이에 대해 본 연구에서는 SIP 말뚝의 주면저항력 특성을 고찰하여 이러한 문제점들을 개선, 보완하기 위하여 다양한 조건에서 SIP 말뚝 주면과 지반흙 사이의 경계면에 대하여 직접전단시험을 실시하였다. 그 결과를 토대로 통일분류상 SM, SC 지반에서의 SIP 말뚝 주면저항력 특성을 고찰하고 해당 지반에서 최대주면저항력 산정식을 제시하였다.