Abstract
Many different modified activated sludge methods are being developed for effective removal of nutrients due to increased interest from society and increasing legal standards on water quality. As a part of this trend. we performed a pilot study of actually applying internal circulation sequencing batch reactor (ICSBR) in sewage/municipal wastewater. The results of the present showed that the removal rate of organic matter of this reactor was 68-95% and the rate of nitrogen removal was higher with higher concentration of organic matter in the raw wastewater. The phosphate removal rate was more than 90% in municipal wastewater, and no significant problem occurred in the management of effluent concentration since it is very minute (less than 1 ppm) in sewage wastewater. The removal rates of nitrogen and phosphate using this equipment was between 80-90%, which was relatively high compared with other processes used in Korea showing the nitrogen and phosphate removal rates of 60-80%. Therefore, the application of internal circulation and step feeding using sludge layer is very effective for advanced wastewater treatment using this sequencing batch reactor.
영양염류에 대한 사회적 관심과 점차적으로 강화되는 법적인 수질 기준에 맞추어 효과적으로 염류를 제거할 수 있는 많은 활성슬러지 변법들이 개발되고 있다. 본 연구에서는 그 일환으로 개량된 연속회분식 반응장치를 실제 하/오수에 적용하여 실험을 실시하였다. 그 결과, 유기물 제거에 있어서 68-95%의 제거효율을 보여 주었으며 원수에 포함된 유기물의 농도가 높을수록 질소제거율이 높은 것으로 나타났다. 오수에 있어서 90% 이상의 인 제거효율을 보여 주었으며 도시하수의 경우 인의 유입 농도가 극히 미량이었기 때문에 (1 ppm 미만) 유출농도 관리에 특별한 문제점은 발생하지 않았다. 본 장치에 의한 질소나 인의 처리효율은 80-90% 이상으로 60-80%의 질소, 인 제거효율을 보이는 국내의 여타 공정에 비해 비교적 높은 제거효율을 가진 것으로 나타났다. 따라서 고도처리를 위한 연속회분식 처리설비에 있어서 슬러지층을 이용한 내부순환 방식과 단계 유입방법의 적용은 매우 효과적이라고 보여진다.