References
- Brooks AL, Jenkins EB : Atlanto-axial arthrodesis by the wedge compression method. J Bone Joint Surg 60A : 279-284, 1978
- Goel A : C1-C2 pedicle screw fixation with rigid cantilever beam construct : case report and technical note. Neurosurgery 51 : 853-854, 2002 https://doi.org/10.1097/00006123-200209000-00058
- Geremia GK, Kim KS, Cerullo L : Complications of sublaminar wiring. Surg Neurol 23 : 629-635, 1985 https://doi.org/10.1016/0090-3019(85)90017-5
- Grob D, Crisco JJ III, Panjabi M, Wang P, Dvorak J : Biomechanical evaluation of four different posterior atlantoaxial fixation techniques. Spine 17 : 480-490, 1992 https://doi.org/10.1097/00007632-199205000-00003
- Harms J, Melcher RP : Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine 26 : 2467-2471, 2001 https://doi.org/10.1097/00007632-200111150-00014
- Henriques T, Cunningham BW, Olerud C : Biomechanical comparison of five different atlantoaxial posterior fixation techniques. Spine 25 : 2877-2883, 2000 https://doi.org/10.1097/00007632-200011150-00007
- Jun BY: Anatomic study for ideal and safe posterior C1-C2 transarticular screw fixation. Spine 23 : 1703-1707, 1998 https://doi.org/10.1097/00007632-199808010-00018
- Magerl F, Seemann PS : Stable posterior fusion of the atlas and axis by transarticular screw fixation in Kehr P, Weidner(eds) : Cervical Spine, New York : Springer, 1986, Vol 1, pp322-327
- McCullen GM, Garfin SR : Spine update : cervical spine internal fixation using screw and screw-plate constructs. Spine 25 : 643-652, 2000 https://doi.org/10.1097/00007632-200003010-00020
- Naderi S, Crawford NR, Song GS : Biomechanical comparison of C1-C2 posterior fixations : Cable, graft, and screw combinations. Spine 23 : 1946-1955, 1998 https://doi.org/10.1097/00007632-199809150-00005
- Oda I, Abumi K, Sell LC : Biomechanical evaluation of five different occipito-atlanto-axial fixation techniques. Spine 24 : 2377-2382, 1999 https://doi.org/10.1097/00007632-199911150-00015
- Puttlitz CM, Goel VK, Traynelis VC : A finite element investigation of upper cervical instrumentation. Spine 26 : 2449-2455, 2001 https://doi.org/10.1097/00007632-200111150-00011
- Resnick DK, Benzel EC : C1-C2 pedicle screw fixation with rigid cantilever beam construct : case report and technical note. Neurosurgery 50 : 426-428, 2002 https://doi.org/10.1097/00006123-200202000-00039
- Resnick DK, Lapsiwala S, Trost GR : Anatomic suitability of the C1-C2 complex for pedicle screw fixation. Spine 27 : 1494-1498, 2002 https://doi.org/10.1097/00007632-200207150-00003
- Richter M, Wilke HJ, Kluger P : Biomechanical evaluation of a new modular rod-screw implant system for posterior instrumentation of the occipito-cervical spine : in-vitro comparison with two established implant systems. Eur Spine J 9 : 417-425, 2000 https://doi.org/10.1007/s005860000173
- Yoon DH, Kim YS : Long term follow up and clinical result of posterior C1/2 fixation. J Korean Neurosurg Soc 28 : 926-933,1999