DOI QR코드

DOI QR Code

THE EFFECT OF VISCOSITY, SPECIMEN GEOMETRY AND ADHESION ON THE LINEAR POLYMERIZATION SHRINKAGE MEASUREMENT OF LIGHT CURED COMPOSITES

점도, 시편형태 그리고 접착의 유무가 광중합 복합레진의 선형중합수축의 측정에 미치는 영향

  • Lee, In-Bog (Department of Conservative Dentistry, College of Dentistry, Seoul National University) ;
  • Son, Ho-Hyun (Department of Conservative Dentistry, College of Dentistry, Seoul National University) ;
  • Kwon, Hyuk-Chun (Department of Conservative Dentistry, College of Dentistry, Seoul National University) ;
  • Um, Chung-Moon (Department of Conservative Dentistry, College of Dentistry, Seoul National University) ;
  • Cho, Byeong-Hoon (Department of Conservative Dentistry, College of Dentistry, Seoul National University)
  • 이인복 (서울대학교 치과대학 보존학교실) ;
  • 손호현 (서울대학교 치과대학 보존학교실) ;
  • 권혁춘 (서울대학교 치과대학 보존학교실) ;
  • 엄정문 (서울대학교 치과대학 보존학교실) ;
  • 조병훈 (서울대학교 치과대학 보존학교실)
  • Published : 2003.11.01

Abstract

The aim of study was to investigate the effect of flow, specimen geometry and adhesion on the measurement of linear polymerization shrinkage of light cured composite resins using linear shrinkage measuring device. Four commercially available composites - an anterior posterior hybrid composite Z100, a posterior packable composite P60 and two flowable composites, Filtek flow and Tetric flow-were studied. The linear polymerization shrinkage of composites was determined using 'bonded disc method' and 'non-bond-ed' free shrinkage method at varying C-factor in the range of 1∼8 by changing specimen geometry. These measured linear shrinkage values were compared with free volumetric shrinkage values. The viscosity and flow of composites were determined and compared by measuring the dropping speed of metal rod under constant load. In non-bonded method, the linear shrinkage approximated one third of true volumetric shrink-age by isotropic contraction. However, in bonded disc method, as the bonded surface increased the linear shrinkage increased up to volumetric shrinkage value by anisotropic contraction. The linear shrinkage value increased with increasing C-factor and approximated true volumetric shrinkage and reached plateau at about C-factor 5∼6. The more flow the composite was, reduced linear shrinkage was measured by compensation radial flow.

Keywords

References

  1. Lai JH and Johnson AE : Measuring polymerization shrinkage of photo activated restorative materials by a water filled dilatometer. Dent Mater 9:139 143, 1993 https://doi.org/10.1016/0109-5641(93)90091-4
  2. Sakaguchi RL, Sasik CT, Bunczak MA and Douglas WH : Strain gauge method for measuring pclymerization contraction of composite restoratives. J Dent 19:312 316, 1991 https://doi.org/10.1016/0300-5712(91)90081-9
  3. Penn RW: A recording dilatometer for measuring poly merization shrinkage. Dent Mater 2: 78 79, 1986 https://doi.org/10.1016/S0109-5641(86)80056-2
  4. Rees JS and Jacobsen PH: The polymerization shrinkage of composite resins. Dent Mater 5:41 44, 1989 https://doi.org/10.1016/0109-5641(89)90092-4
  5. Sakaguchi RL, and Berghe HX : Reduced light energy density decreases post gel contraction while maintaining degree of conversion in composites. J Dent 26;695 700, 1998 https://doi.org/10.1016/S0300-5712(97)00048-1
  6. Suh Bl, Feng L, Wang Y, Cripe C, Cincione F and de Rjik W : The effect of the pulse delay cure technique on residual strain in composites. Compendium Vol.20, No.2;4 14, 1999
  7. Silikas N, Eliades G and Watts DC : Light intensity effects on resin composite degree of conversion and shrinkage strain. Dent Mater 16:292 296, 2000 https://doi.org/10.1016/S0109-5641(00)00020-8
  8. Cook WD, Forrest M and Goodwin AA : A simple method for the measurement of polymerization shrinkage in dental composites. Dent Mater 15:447 449, 1999 https://doi.org/10.1016/S0109-5641(99)00073-1
  9. Puckett AD and Smith R : Method to measure the polymerization shrinkage of light cured composites. J Prosthet Dent 68:56 8, 1992 https://doi.org/10.1016/0022-3913(92)90285-I
  10. de Gee AJ, Feilzer AJ and Davidson CL ; True linear polymerization shrinkage of unfilled resins and com poaites determined with a Iincmeter. Dent Mater 9:11 14, 1993 https://doi.org/10.1016/0109-5641(93)90097-A
  11. Venhoven BAM, de Gee AJ and Davidson CL : Polymerization contraction and conversion of light curing BisGMA based methacryate resins. Biomaterials 14(11) :871 875, 1993 https://doi.org/10.1016/0142-9612(93)90010-Y
  12. Feilzer AJ, de Gee AJ and Davidson CL : Curing contraction of composites and glass ionomer cements. J Prosthet Dent 59:297 300, 1988 https://doi.org/10.1016/0022-3913(88)90176-X
  13. Fano V, Ortalli l, Pizzi Sand Bonanini M : Polymerization shrinkage of microfilled composites determined by laser beam scanning. Biomaterials 18:467 470, 1997 https://doi.org/10.1016/S0142-9612(96)00171-8
  14. Watts DC and Marouf AS: Optimal specimen geometry in bonded disc shrinkage strain measurements on light cured biomaterials. Dent Mater 16:447 451. 2000 https://doi.org/10.1016/S0109-5641(00)00043-9
  15. Watts DC and Cash AJ: Determination cf polymerization shrinkage kinetics in visible light cured materials : methods development. Dent mater 7:281 287, 1991 https://doi.org/10.1016/S0109-5641(05)80030-2
  16. Feilzer AJ, de Gee AJ and Davidson CL: Increased wall to wall curing contraction in thin bonded resin layers. J Dent Res 68:48 50, 1989 https://doi.org/10.1177/00220345890680010701
  17. Lee IB : A new method ? Real time measurement of the initial dynamic volumetric shrinkage of composite resins during polymerization. Korean Academy of Cons Dent 26:134 140, 2001
  18. Opdam NJM, Roeters JJM, Peters TCRB, et al. Consistency of resin composites for posterior use. Dent Mater 1996; 12: 350 354 https://doi.org/10.1016/S0109-5641(96)80045-5
  19. Bayne SC, Thompson JY, Swift EJ, et al. A characterization of first generation flowable composites. JADA 1998; 129: 567 577 https://doi.org/10.14219/jada.archive.1998.0274
  20. Labella R, Lambrechts P, van Meerbeek B and Vanherle G : Polymerization shrinkage and elasticity of flowable composites and filled adhesives. Dent Mater 15:128 137, 1999 https://doi.org/10.1016/S0109-5641(99)00022-6
  21. Lee IB, Son HH and Um CM: Rheologic properties of flowable, conventional hybrid and condensable composite resins. Dent Mater 19: 298 307, 2003
  22. Tyas MJ, Jones DW and Rizkalla AS : The evaluation of resin composite consistency. Dent Mater 14:424 428, 1998 https://doi.org/10.1016/S0300-5712(99)00017-2
  23. Feilzer AJ, de Gee AJ and Davidson CL : Setting stress in composite resin in relation to configuration of the restoration. J Dent Res 66:1636 9, 1987 https://doi.org/10.1177/00220345870660110601
  24. Watts DC and Al Hindi A : Intrinsic 'soft start' poly merization shrinkage kinetics in a acrylate based resin composite. Dent Mater 15:39 45, 1999
  25. Barnes HA, Hutton JF, Walters K : An introduction to rheology, 1st ed. Amsterdam: Elsevier Science Publishing co. 1989

Cited by

  1. Influence of cavity size and restoration methods on the cusp deflection in composite restoration vol.29, pp.6, 2004, https://doi.org/10.5395/JKACD.2004.29.6.532