DOI QR코드

DOI QR Code

Development and Construction of low Magnetic Field Control System for Analysis of Magnetic Field Effect in the Deflection Yoke

브라운관의 자기장 영향 분석용 저자기장 제어 장치의 설계 및 제작

  • 박포규 (한국표준과학연구원, 전자기표준연구부) ;
  • 김영균 (한국표준과학연구원, 전자기표준연구부) ;
  • 신석우 (한국표준과학연구원, 전자기표준연구부) ;
  • 최형호 ((주)대동전기) ;
  • 김태익 ((주)대동전기) ;
  • 정동근 (구미기능대학, 전자과)
  • Published : 2003.12.01

Abstract

We have developed the quality analysis system for magnetic field effect of cathode-ray tube that is used a monitor, TV and medical appliance. We designed and constructed the large 3-axis square coil (2 m length) system for the generation of 3-component magnetic field using power supply, magnetometer and computer below 0.2 mT range. The coil constant is 30.31 ${\mu}$T, 29.73 ${\mu}$T and 30.51 ${\mu}$T for the X, Y and Z axis square coil respectively. The magnetic field resolution was 0.01 T. The uniformity of magnetic field was measured within 1 % in the range of 12 cm.

컴퓨터, TV, 의료용기기 등의 모니터로 사용되는 브라운관의 자기장 영향에 따른 특성을 분석하기 위한 자기장 발생 및 측정장치를 개발하였다. 한 변의 길이가 2 m인 정육각형 형태의 3-축 자기장 발생장치, 컴퓨터, 전원공급기 및 자기장 측정기 등을 이용하여 전세계 각 나라별 지구자기장(Earth Magnetic Field, EMF)을 발생시킬 수 있는 대형 3-축 코일 시스템을 설계하고 제작하였다. 각 코일의 코일상수는 X축(E-W)는 30.31 $\mu$T/A, Y축(Ver)는 29.73 $\mu$T/A 및 Z축(N-S)는 30.51 $\mu$T/A이고, 자기장 분해능은 0.01 $\mu$T이었다. 자기장 균일도는 사용되는 편향요크(Deflection York, DY)의 크기를 고려하여 중심에서 12 cm 이내의 공간에서 측정하였고, 균일도는 1 % 내외 이었다.

Keywords

References

  1. 전파연구소 이천분소 우주환경예보 표유선
  2. Geomagnetic Field Data Plot Tsutomu Nagatsuma;Hiromitsu Ishibashi
  3. 삼성 SDI 삼성 SDI
  4. Rev. Sci. Instrum. v.37 A.H.Firester https://doi.org/10.1063/1.1720478
  5. Ungyong Mulli v.9 no.3 Po Gyu Park;C.G.Kim;B.C.Woo;V.Ya.Shifrin
  6. 석사학위논문, 한남대 박포규
  7. Introduction to Geomagnetism W.D.Parkinson
  8. 지자기 전국관측망 구축을 위한 연구회 보고서 자자기와 그의 역할 임무택(외)
  9. Kaist
  10. J. Kor. Mag. Soc. v.9 no.5 J.H.Jung;P.G.Park;Y.B.Kim;V.Ya.Shifrin;V.N.Khorev
  11. Rev. Sci. Instrum. v.42 no.10 R.L.Driscoll;P.T.Olsen https://doi.org/10.1063/1.1684898
  12. IEC 61786 Ed.1: measurement of low-frequency magnetic and electric fields with regards to exposure of human beings-Special requirements for instruments and guidance for measurement
  13. J. Kor. Mag. Soc. v.11 no.1 P.G.Park;Y.G.Kim;V.Ya.shifrin;V.N.Khorev

Cited by

  1. Design of Electronic Ballast for 35[W] Ceramic Metal Halide Lamp by DBI Structure vol.24, pp.9, 2010, https://doi.org/10.5207/JIEIE.2010.24.9.001
  2. Performance Evaluation of Low Frequency Magnetic Field Shielding by Eddy-Current vol.24, pp.9, 2010, https://doi.org/10.5207/JIEIE.2010.24.9.124
  3. Design of Magnetic Field Compensation System Model for AC Magnetic Field Shielding vol.25, pp.7, 2011, https://doi.org/10.5207/JIEIE.2011.25.7.078