A Study on measurement of scattery ray of Computed Tomography

전산화 단층촬영실의 산란선 측정에 대한 연구

  • Cho, Pyong-Kon (Dept., of the diagnostic radiology Anam Hospital of Korea University Medical Center) ;
  • Lee, Joon-Hyup (Dept., of the diagnostic radiology Anam Hospital of Korea University Medical Center) ;
  • Kim, Yoon-Sik (Dept., of the diagnostic radiology Anam Hospital of Korea University Medical Center) ;
  • Lee, Chang-Yeop (Dept., of the diagnostic radiology Anam Hospital of Korea University Medical Center)
  • 조평곤 (고려대학교 안암병원 진단방사선과) ;
  • 이준협 (고려대학교 안암병원 진단방사선과) ;
  • 김윤식 (고려대학교 안암병원 진단방사선과) ;
  • 이창엽 (고려대학교 안암병원 진단방사선과)
  • Published : 2003.06.30

Abstract

Purpose : Computed tomographic equipment is essential for diagnosis by means of radiation. With passage of time and development of science computed tomographic was developed time and again and in future examination by means of this equipment is expected to increase. In this connection these authors measured rate of scatter ray generation at front of lead glass for patients within control room of computed tomographic equipment room and outside of entrance door for exit and entrance of patients and attempted to ind out method for minimizing exposure to scatter ray. Material and Method : From November 2001 twenty five units of computed tomographic equipments which were already installed and operation by 13 general hospitals and university hospitals in Seoul were subjected to this study. As condition of photographing those recommended by manufacturer for measuring exposure to sauter ray was use. At the time objects used DALI CT Radiation Dose Test Phantom fot Head (${\oint}16\;cm$ Plexglas) and Phantom for Stomache(${\oint}32\;cm$ Plexglas) were used. For measurement of scatter ray Reader (Radiation Monitor Controller Model 2026) and G-M Survey were used to Survey Meter of Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion Chamber, S/N 21740. Spots for measurement of scatter ray included front of lead glass for patients within control room of computed tomographic equipment room which is place where most of work by gradiographic personnel are carried out and is outside of entrance door for exit and entrance of patients and their guardians and at spot 100 cm off from isocenter at the time of scanning the object. The results : Work environment within computed tomography room which was installed and under operation by each hospital showed considerable difference depending on circumstances of pertinent hospitals and status of scatter ray was as follows. 1) From isocenter of computed tomographic equipment to lead glass for patients within control room average distance was 377 cm. At that time scatter ray showed diverse distribution from spot where no presence was detected to spot where about 100 mR/week was detected. But it met requirement of weekly tolerance $2.58{\times}10^{-5}\;C/kg$(100 mR/week). 2) From isocenter of computed tomographic equipment to outside of entrance door where patients and their guardians exit and enter was 439 cm in average, At that time scatter ray showed diverse distribution from spot where almost no presence was detected to spot with different level but in most of cases it satisfied requirement of weekly tolerance of $2.58{\times}10^{-6}\;C/kg$(100 mR/week). 3) At the time of scanning object amount of scatter ray at spot with 100 cm distance from isocenter showed considerable difference depending on equipments. Conclusion : Use of computed tomographic equipment as one for generation of radiation for diagnosis is increasing daily. Compared to other general X-ray photographing field of diagnosis is very high but there is a high possibility of exposure to radiation and scatter ray. To be free from scatter ray at computed tomographic equipment room even by slight degree it is essential to secure sufficient space and more effort should be exerted for development of variety of skills to enable maximum photographic image at minimum cost.

목 적 : 전산화 단층촬영장치는 방사선을 이용한 질병의 진단에 중추적인 역할을 하는 장비이다. 시대의 흐름과 과학기술의 발달로 전산화 단층촬영장치도 그 발전을 거듭해왔고 앞으로도 전산화 단층촬영장치를 이용한 검사는 더욱더 증가하리라 생각된다. 검사의 증가와 함께 산란선에 노출될 기회가 많아질 것이라는 생각 또한 사실이다. 이에 전산화 단층촬영실의 제어실내 환자 보기창 앞과 환자 및 보호자들이 출입하는 출입문 외측 그리고 환자 검사 시 촬영실내에서의 산란선 발생률을 측정하였고 산란선의 피폭을 가장 최소화 할 수 있는 방법을 알아보고자 하였다. 대상 및 방법 : 2001년 11월부터 서울소재 13개 종합병원 및 대학병원에 설치 운용중인 전산화 단층촬영장치 25를 대상으로 하였다. 촬영조건은 피폭선량 측정시 제조업소에서 권고 하고있는 촬영조건을 사용하였고, 이때 피사체는 피폭선량 측정용 DALI CT 피폭선량 측정용 두부용 팬톰(${\phi}16\;cm$ Plexglas)과 복부용 팬톰(${\phi}32\;cm$ Plexglas)을 사용하였다. 산란선의 측정은 환경방사선 측정용 Survey Meter인 Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion chamber, S/N 21740에 Reader(Radiation Monitor Controller model 2026)과 G-M Survey를 이용하였다. 산란선의 측정위치는 전산화 단층촬영실에서 방사선 작업종사자가 주로 활동하는 제어실내 환자 보기창 앞과 환자 및 보호자들이 출입하는 출입문 외측 그리고 피사체 스캔시 등선량중심점(isocenter)으로부터 100 cm되는 지점에서 측정하였다. 결 과 : 각 병원에서 설치 운용중인 전산화 단층촬영실내 작업환경은 해당병원의 상황에 따라 많은 차이를 보이고 있었고 산란선의 발생유무는 다음과 같았다. 1) 전산화 단층촬영장치의 등선량중심점(isocenter)에서부터 제어실내 환자 보기창 사이의 거리는 평균 377 cm이였고 이때 산란선은 거의 검출되지 않은 곳에서부터 약 100 mR/week까지 다양한 분포를 보였으나 주당 허용선량인 $2.58{\times}10^{-5}\;C/kg$(100 mR/week)이내의 조건을 만족하고 있었다. 2) 전산화 단층촬영장치의 등선량중심점(isocenter)에서부터 환자 및 보호자가 출입하는 출입문 외측까지의 거리는 평균 439cm이었고, 이때 산란선은 거의 검출되지 않은 곳부터 다양한 분포를 보였으나 대부분의 병원에서 주당허용선량인 $2.58{\times}10^{-6}\;C/kg$(10 mR/week)이내의 조건을 만족하고 있었다. 3) 피사체를 스캔할 때 등선량중심점(isocenter)에서부터 100 cm되는 곳에서의 산란선량은 장비에 따라 많은 차이가 있었다. 결 론 : 진단용 방사선발생장치에서 전산화 단층촬영장치의 이용은 나날이 증가하고 있고 다른 일반 X-선 촬영과 비교했을 때 진단영역이 매우 높지만 방사선으로 인한 피폭과 산란선에 노출될 가능성이 매우 높다. 전산화 단층촬영실에서 산란선으로부터 조금이라도 자유로워지기 위해서는 설계단계에서부터 충분한 공간 확보가 우선되어야하고 모든 검사에서 방사선사는 최소의 선량으로 최상의 영상을 제공할 수 있는 다양한 기술개발에 더욱 노력을 아끼지 말아야 할 것으로 생각된다.