Rapid Prototyping Assisted Orthopaedic Fracture Surgery - A Case Report -

쾌속조형공정 지원 정형외과 골절 수술 - 증례 보고 -

Sohn, Hong-Moon;Lee, Jun-Young;Ha, Sang-Ho;Yoo, Jae-Won;Lee, Sang-Hong;Ahn, Dong-Gyu
손홍문;이준영;하상호;유재원;이상홍;안동규

  • Published : 20040000

Abstract

New surgical techniques utilizing computer-aided engineering have been recently developed to improve the quality of surgery and reduce the risk to patients. This paper reports the surgical cases using rapid prototyping assisted orthopeadic fracture surgery (RPAOFS). RPAOFS utilizes the symmetric characteristics of the human body, and the potential for RE and RP in which the physical shape is manufactured repidly from the CT data. The physical shape before the injury was manufactured from the RP using the mirror transformed CAD data of the uninjured extents. Subsequently, pre-operative planning, such as the selection of the proper implant, preforming of the implant, selection of the fixation positions, and surgery are performed utilizing the physical shape. RPAOFS was applied to two cases such as a distal tibia communited fracture and a proximal tibia plateau fracture. The surgical results showed that RPAOFS is an effective surgical tools.

최근 수술 결과의 개선과 환자에 대한 위험 감소를 위하여 컴퓨터 응용기술을 이용한 새로운 수술 기법들이 개발되고 있다. 본 연구에서는 쾌속조형공정 지원 정형외과 골절수술기법(RPAOFS)의 적용 증례에 대한 결과보고이다. RPAOFS은 인체의 대칭 특성과 역공학 및 쾌속조형공정의 기술적조합의 장점인 골의 손상없이 CT 데이터로부터 3차원 실물형상의 쾌속제작 특성을 이용한다. 환측의 골절전 원형골 실물형상은 건측의 CT 데이터를 역공학으로 3차원 복원하고, 이 데이터를 거울 대칭 변환하여 환측의 골절전 원형골 CAD 데이터를 생성하여 Objet 쾌속조형공정을 이용하여 제작하였다. 제작된 환측 골절전 원형골 실물형상을 이용하여 인체 형상에 적합한 내고정물 선정 및 내고정물 사전 성형, 내고정물 위치 및 고정위치 선정, 수술 경로 결정 등 사전 수술 계획 수립과 시술을 수행하였다. RPAOFS을 경골 원위부 분쇄골절과 경골 근위부 함몰 골절에 대하여 적용하였다. 수술 결과, 수술 시간, 방사선 투사횟수, 절개 크기 등을 최소화할 수 있었으며 환자의 재활 속도가 현저히 빨라짐을 알 수 있었다. 이 결과로부터 RPAOFS가 효과적인 정형외과 골절 수술 방법임을 알 수 있었다.

Keywords

References

  1. Brown GA, Brenton M and Firoozbaksh K: Application of computer-generated stereolithography and interpositioning template in acetabular fracture: a report of eight case. J Orthop Trauma, 16:347-352, 2002. https://doi.org/10.1097/00005131-200205000-00010
  2. Goto M, Katsuki T, Noguchi H and Hino N: Surgical simulation for reconstruction of mandibular bone defects using photocurable plastic skull models: report of three cases. J Oral Maxillofac Surg, 55: 772-780, 1997. https://doi.org/10.1016/S0278-2391(97)90597-8
  3. Kai CC, Meng CS, Ching LS, Hoe EK and Fah LK: Rapid prototyping assisted surgery planning. Int J Adv Manuf Tech, 14:624-630, 1998. https://doi.org/10.1007/BF01192281
  4. Kulkarni P, Marson D and Dutta D: A review of process planning techniques in layered manufacturing. Rapid Prototyping Journal, 6: 18-35, 2000. https://doi.org/10.1108/13552540010309859
  5. McFerran MA, Smith SW, Boulas HJ, et al: Complications encountered in the treatment of pilon fractures. J Orthop Trauma, 6: 195-200, 1992. https://doi.org/10.1097/00005131-199206000-00011
  6. Potamianos P, Amis AA, Forester AJ, McGurk M and Bircher M: Rapid prototyping for orthopaedic surgery. Proc Inst Mech Engr (H), J of Engrs in Medicine, 212: 383-393, 1998.
  7. Schatzker J, McBroom R and Bruce D: The tibial plateau fracture. The Toronto experience 1968--1975. Clin Orthop, 138: 94-104, 1979.
  8. Wade RH, Kevu J and Doyle J: Preoperative planning in orthopaedics; a study of surgeons’ opinions. Injury, 29: 785-786, 1998. https://doi.org/10.1016/S0020-1383(98)00192-2
  9. Wenda K, Runkel M, Degrief J and Rudig L: Minimally invasive plate fixatiohn in femoral shaft fractures. Injury, 28 (Suppl 1):13-19, 1997. https://doi.org/10.1016/S0020-1383(97)90111-X
  10. Wholer T: Wholers report 2003, Rapid prototyping & tooling state of the industry, Wholers Associates Inc, 2003.