Epidemiologic Investigation into an Outbreak of Typhoid Fever Recognized byElectronic Data Interchange in Gyeongsangbuk-do, 2003

2003년 경상북도에서 감시체계로 인지된 장티푸스의 발생원인

Lim, Hyun-Sul;Min, Young-Sun;Lee, Kwan;Lim, Sang-Hyuk
임현술;민영선;이관;임상혁

  • Published : 20040000

Abstract

Epidemiologic investigation into an Outbreak of Typhoid Fever Recognized by EIectronic Data Interchange inGyeongsangbuk-do, 2003Purpose Fourteen cases of typhoid fever occurred in Gyeongsan-si, Gyeongsangbuk-do from May 22 to July 19, 2003.Especially, 6 cases were students of Y University located in Gyeongsan-si This investigation was carried out to study theinfection source and transmission of typhoid fever and to institute an effective prevention counterplanMethods The authors conducted an epidemiologic survey from June 25, 2003 among the 14 cases, restaurants andemployees of the whole neighborhood of Y University Widal test was carried out for the restaurant employees andschoolmates of the 13-year-old case Miss Kim The authors executed a pulsed field gel electrophoresis (PFGE) forSalmonella typhi cultured from 9 cases The authors collected data about chloride and turbid levels of treated water fromApril to June in Gyeongsan-si water treatment. plant and repair work records of waterworks pipe line in Gyeongsan-si city hall Results All cases had used restaurants of the whole neighborhood of Y Umversity within 2 months before the typhoidfever symptoms were developed, but the restaurant that was rarely visited by any of the patients had a case to be matched Inthe results of the Widal test, 9 out of 45 of subjects (20 0%) were suspicious cases or showed a value to suggest pastinfection, in the results of PFGE test, there were 3 subtypes, and each subtype had a similar DNA fragments array In allcases the patients drank tap water when they visited the restaurants The restauiants provided dnriking water from filtered tapwater rather than boiled water, and all patients had drunk this water The chlorine level of the treated water was the normalvalue in the Gyeongsan-si water treatment plant, but in 21 times the value was the minimum standard level There was waterpipe construction woik in some tegions of the whole neighborhood of Y University The number of gastromtestmal patientsin 2003 was approximately 21 times that in 2002 at the health center in Y Umversity.Conclusions The possibility that typhoid fever was generated in the whole neighborhood of Y University is very highAmong various possibilities, the highest possibility is the pollution of tap water intake by water leakage of a water pipeThere was no case of patient infection after strengthening of the tap water disinfection Thorough disinfection, boileddrinking water and a periodic carrier inspection are necessary to prevent additional local occurrencea of these typhoid infections

Keywords

References

  1. 김정순 한국인의 건강과 질병양상 서울 신광출판사, 2001.p.187-95
  2. 국립보건원 2002 전염병 통계연보; 2003
  3. Kanuki S, Revathi G, Muyodi J, Mwituna J,Munyalo A, Mirza S et al. Characterization ofmultidrug-resistant typhoid outbreaks m Kenya. JClin Microbiol 2004;42(4) 1477-82 https://doi.org/10.1128/JCM.42.4.1477-1482.2004
  4. Swammathan B, Barrett TJ, Hunter SB, Tauxe RV, CDC PulseNet Task Force PulseNet. the molecular subtyping network for foodborne bactenai disease sutveillance, United States. Emerg Infect Dis 2001,7(3).382-9 https://doi.org/10.3201/eid0703.017303
  5. Tenover FC, Arbeit RD, Goering RV, Mickelsen PA, Murray BE, Persing DH et al Interpreting chromosomal DNA restriction patterns produced by pulsed-field gel electrophoresis criteria for bactenal strain typing J Clin Microbiol 1995;33(9)2233-9
  6. Thone KL, Puthucheary S, Yassin RM, Sudarmono P, Padmidewi M, Soewandojo E et al Analysis of Salmonella typhi isolates from Southeast Asia by pulsed-field gel electrophoresis. b Clin Microbiol 1995,33(7).1938-41
  7. 신영학, 유정식, 박미선, 강연호, 이복권, 김호훈 1996년 부산시에서 집단발생한 장티푸스 환자들로 부터 분리한 Salmonella typhi의 PFGE양상, Phage형 및 항균제감수성. 감염 1997;29(3).201-8
  8. Olsen SJ, Bleasdale SC, Magnano AR, Landrigan C, Holland BH, Tauxe RV et al. Outbreaks of typhoid fever in the United States, 1960-99. Epidemiol Infect 2003,130(1).13-21 https://doi.org/10.1017/S0950268802007598
  9. 김정순. 1983년 W시에 집단발생한 장티푸스의 감염원구명을 위한 역학조사. 한국역학회지 1983;5(1)140-7
  10. 김정순, 허용, 이성수, 이덕형, 손건영. 이성우 온천 도시 및 그 위성농촌에 발생한 장티푸스 유행의 역학적 특성. 한국역학회지 1988,10(1).92-101
  11. 신해림, 서병성, 송주복, 이덕희, 이맹복, 박진형 등 부산시 장티푸스 유행에 관한 역학조사연구 한국역학회지 1997;19(2).122-30
  12. 정원식, 이현동, 김이태, 유명진 상수도관의 노후도에 대한 환경영향인자의 상관성 분석 상하수도학회지 2003,17(2) 242-9
  13. 최연정, 박종웅, 옥치상. 노후 상수도관중 잔류염소가 음용수 수질에 미치는 영향 대한환경공학회지 1992,14(4):289-98
  14. 이현동, 정원식, 지재성. 상수도관망내 잔류염소분해 및 수질변화 특성. 한국수질보전학회지 1998,14(1)79-86
  15. 김철호, 조용운, 김홍철, 이상원 수돗물과 정수기물의 미생물학적 수질. 진주산업대논문집 1999,38 207-14
  16. Xercavins M, Llovet T, Navarro F. Morera MA, More J, Bella F et al. Epidemiology of an unusually prolonged outbreak of typhoid fever in Terrassa, Spain. Clin Infect Dis 1997,24(3).506-10 https://doi.org/10.1093/clinids/24.3.506
  17. Murray PR, Rosenthal KS, Kobayashi GS, Pfaller MA. Medical Microbiology. 4th ed Saint Louis. Mosby, 2002 p 274-5