Health Risk Assessment of Exposure to Indoor Air Pollutants in Office Building

사무실 실내공기오염물질 노출에 의한 건강위해성평가

Lee, Cheol-Min;Kim, Yun-Sin;No, Yeong-Man;Kim, Jong-Cheol;Jeon, Hyeong-Jin;Lee, So-Dam
이철민;김윤신;노영만;김종철;전형진;이소담

  • Published : 20041200

Abstract

This study collected and re-analysed the articles of exposure assessment for the indoor environment of offices in journals related environment in Korea since 1990, and estimated the unit health risk on indoor environment. The objective of this study was to offer scientific data for decision-making of policy for improvement and management of indoor air quality on office in Korea. The pooled concentration for the critical air pollutants in the office was estimated 114 ± 84 /m3 for respirable ㎍ particle, 2 ± 1.6 ppm for carbon monoxide and 1,008 ± 983 ppm for carbon dioxide, respectively. And the pooled concentration for the volatile organic compounds was estimated 11.1 ± 13.1 /m ㎍3 for benzene, 65,8 ± 79.8 /m ㎍3 for toluene, 7.7 ± 9.3 /m3 for ethylbenzene, 23.1 ㎍± 25.6/m ㎍3 for m-p-xylene, 5.5 ± 5.2 /m ㎍3 for styrene and 14.6 ± 17.9 /m3 for o-xylene, respectively. The result of the risk ㎍ assessment for the critical pollutants by Monte Carlo analysis showed that the probability of the safety factor exceeded 1 was 36.83% for respirable particle and 99.12% for carbon dioxide, respectively. The unit cancer risk for men and women by inhalation of benzene was 8.9 × 10-6 and 6.1 × 10-6, respectively. And hazard indexes for toluene, ethylbenzene, m-p-xylene, styrene, and o-xylene were less than 1.

제시하면 다음과 같다.첫째 사무실의 실내공기 중 호흡성분,12 이철민 김윤신 노영만 김종철 전형진 이소담 진의 병합평균농도는 114 84 /m㎍3일,산화탄소는 21.6 이산화탄소는 ppm,1,008 983 로 조사되었으며 이들 중 ppm ,이산화탄소만이 산업보건기준에서 정하고 있는 기준치를 초과하고 있는 것으로조사되었다.둘째 휘발성유기화합물질의 사무실 ,내공기 중 병합평균농도는 은Benzene11.1 13.1 /m㎍3 은 , Toluene 65,8 79.8㎍/m3은 , Ethylbenzene 7.7 9.3 /m㎍3,은 m-p-Xylene 23.1 25.6 /m㎍3 은 , S t y l e n e5.5 5.2 /m㎍3 은 , o-Xylene 14.6 17.9㎍/m3로 조사되었다.셋째 기준공기오염물질에 대한 몬테카,를로 분석을 이용한 건강위해성평가 결과호흡성분진 및 이산화탄소의 안전계수가을 초 과 할 확 률 이 각 각1 36.83%, 99.12%로 사무실 실내공기중 이들 두 오염물질에 대 한 제 어 활 동 이 활 발 히 이 루 어 져 야할 것으로 조사되었다.넷째 휘발성유기화합물질에 의한 발암,및 비발암성 위해성평가 결과 발암물질인의 흡 입 으 로 인 한 발 암 위 해 도 는 Benzene남여 각각 8.9 10-6, 6 . 1 1 0-6으로 미국환경보호청에서 권장하고 있는 허용기준치인 10-6을 초과하는 것으로 조사되었으나 비발암성물질인, Toluene,Ethylbenzene, m-p-Xylene, Styrene,의 흡입으로 인한 위해도지수는 o-Xylene미국 환경보호청에서 권장하고 있는 허용기준치인 을 초과하지 않는 것으로 조사1되었다.이 연구는 과거 연구자료에 의존하여수행된 연구로 과거자료의 빈약성 등으로인해 산출된 결과의 의미해석에 있어 오해가 발생할 가능성이 높다 그러나 본 연.구의 수행을 통해 다음과 같은 향후 연구방향을 제시할 수 있다 첫째 보다 체계. ,적이며 장기적인 사무실 내공기질에,대한 실태조사가 요구된다 둘째 과거 기. ,준오염물질을 대상으로 수행 되어오던 사무실 실내공기질 관련 연구에서 유해공기오염물질로의 연구 확대가 요구된다 셋.째 규제기준오염물질의 흡입에 의한 건,강상의 불편함의 유발 여부를 나타내는지표 및 정밀한 건강위해성평가 수행의여부와 저감방안의 설립 마련 여부의 판정에 있어 안전계수를 이용한 건강위해성평가방법의 적극적 활용을 권장한다.

Keywords

References

  1. 김윤신, 이철민, 문정숙, 김상욱. 서울. 경기지역 초중고등학교 교실의 실내공기오염에 관한 연구. 한국학교보건학회지 2003;16(1):81-90
  2. 김윤신, 이철민, 김현탁. Takao Iida, Alpha Track Detector를 이용한 실내외 라돈 농도조사에 관한 연구. 한국환경위생학회지 2002;28(%):71-76
  3. 남보현, 황인조, 김동술. 분산주성분 분석을 이용한 실내환경 중 PM-10 오염의 패턴분류. 한국대기환경학회지 2002;18(1):25-37
  4. 박정균, 윤재웅. 다중 공중이용시설의 실내환경 관리 수준과 영향요인의 분석. 환경관리학회지 2003;9(1):49-56
  5. 방선재, 이철민, 김윤신, 선우 영. 중앙집중식 냉방시설의 냉각탑수중 레지오넬라균과 실내외 미생물 분포에 관한 연구. 한국환경위생학회지 2002;28 (3):39-48
  6. 백성옥, 김영민. 도시지역에서의 실내외 주변공기 중 휘발성유기화합물의 농도측정에 관한 연구. 대한환경공학회지 1996;18(2):181-197
  7. 손혜향. 메타분석법. 자유아카데미; 1992
  8. 손혜향. 의학, 간호학, 사회과학 연구의 메타분석법. 청문각; 1998
  9. 신동천, 이효민, 김종만, 정용. 일부지역의 실내공기오염도와 건강에 미치는 영향에 관한 연구 한국대기보전학회지 1990;6(1):73-84
  10. 신혜수, 김윤신, 허귀석. 실내외 공기중 휘발성유기화합물질(VOCs)의 농도 조사에 관한 연구. 한국대기보전학회지 1993;9(4):310-319
  11. 환경부. 노출평가지침서. 2001
  12. 황승만, 신주희, 정진욱, 박상곤, 백성옥. 흡연 및 비흡연 사무실의 실내공기질 비교 평가. 한국대기환경추계학술대회 관동대학교 양양캠퍼스 1999
  13. Abbey DE, Burchette RJ, Knutsen SF, McDonnell WF, Lebowitz MD, Enright PL. Long-term particulate and other air pollutants and lung function in non-smokers. American Journal of Respiratory Critical Care Medicine 1998;158(1):289-298
  14. Adams WC. Measurement of breathing rate and volume in routinely performed daily activities, final Report. California Air Resources Board(CARB) Contract No. A033-205. June 1993. p.185
  15. Akland GG, Hartwell TD, Johnson TR, Whitmore RW. Measureing human exposure to carbon monoxide in Washington, D.C and Denver, Colorado, during the winter of 1982-1983, Environmental Science and Technology 1985;19(10):911-918 https://doi.org/10.1021/es00140a004
  16. Arashidani K, Yoshikawa M, Kawamoto T, Matsuno K, Kayama F, Kodama Y. Indoor pollution from heating. Industrial Heath 1996;34(3):205-215 https://doi.org/10.2486/indhealth.34.205
  17. Clayton CA, Perritt RL, Pellizzari ED, Thomas KW, Whitmore RW, Ozkaynak H, Spengler JD, Wallace LA. Particle total exposure assessment methodology(PTEAM) study: distributions of aerosol and elemental concentrations in personal, indoor, and outdoor air samples in a Southern California community, Journal of Exposure Analysis and Environmental Epidemiology 1993;3(2):227-250
  18. Coultas DB, Lambet WE. Carbon monoxide. In: Sanet JM, Spengler JD. (Eds.), Indoor Air Pollution: A Health Perspective. Johns Hopkins University Press, Baltimore, MD; 1991. p.197-208
  19. Gold DR. Indoor air pollution, Clinics in Chest Medicine 1992;13(2):215-229
  20. Institute for Environment and Health(IEH), IEH assessment on indoor air quality in the home. Institute for Enviornment and Health, Leicester, UK, 1996
  21. Janssen NA, Hoek G, Brunekreef B, Harssema H, Mensink I, Zuidhof A. Personal sampling of particles in adults: relation among personal, indoor, and outdoor air concentrations. American Journal of Epidemiology 1998;147(6):537-547
  22. Koenig JQ, Larson TV, Hamley QS, Rebolledo V, Dumler K, Checkoway H, Wang SZ, Lin D, Pierson WE. Pulmonary lung function in children associated with fine particulate matter, Environmental Research 1993;63(1): 26-38 https://doi.org/10.1006/enrs.1993.1123
  23. Lambert WE. Combustion pollution in indoor environments, In: Bardana EJ, Montanaro A. (Eds.), Indoor Air Pollution and Health. Marcel Dekker, New York;1997. p.83-103
  24. Lee SC and M, Chang LY. Indoor air outdoor air quality investigation at schools in Hong Kong, Chemosphere; 2000. p.40, p.109-113
  25. Lende R. Health aspects related to indoor air pollution. Inter. J. Epidemiology 1980;9(3)
  26. Madany IM. Carboxyhemoglobin levels in blood donors in Bahrain, Science of the Total Environment 1992;116(1):53-58 https://doi.org/10.1016/0048-9697(92)90364-X
  27. Maroni M, Seifert B, Lindvall T (Eds.). Indoor Air Quality-a Comprehensive Reference Book. Elsevier, Amsterdam. 1995
  28. Molbare, L., Indoor air pollution due to organic gases and vapors of solvents in building materials. Environ. Int. 1982
  29. Moriske JJ, Drews M, Ebert G, Menk G, Shceller C, Sch.ndube M, Konieczny L. Indoor air pollution by different heating systems: coal burning, open fireplace and central heating. Toxicology Letters 1996;88(1-3):49-354
  30. National Academy of Sciences(NAS), Human exposure assessment for airborne pollutants, Washington DC. 1993
  31. National Aeronautics and Space Administration(NASA), Bioastronautics Data Book - SP 3006. NASA, Washington, D.C. 1973
  32. Otto DA, Hudnell HK. The use of visual and chemosensory evoked-potenials in environmental and occupational health environ. Res 1993;62(1):159-171
  33. Roman Meininghanus, Amin Kouniali, Corinne Mandin and Andre Cicolella. Risk assessment of sensory irritants in indoor air-a case study in a french school, Environment International; 2003. p.28
  34. Roughton FJW, Darling RC. The effect of carbon monoxide on the oxyhemoglobin dissociation curve. American Journal of Physiology 1994;141(1): 17-31
  35. Scjwarzberg MN. Carbon dioxide level as migraine threshold factor: hypothesis and possible solutions. Medical Hypotheses 1993;41(1):35-36 https://doi.org/10.1016/0306-9877(93)90030-T
  36. Sisovic E, Fugas M, Sega K. Assessment of human inhalation exposure to polycyclic aromatic hydrocarbons. Journal of Exposure Analysis and Environmental Epidemiology 1996; 6(4):439-447
  37. Spengler JD, Sexton K. Indoor air pollution: a public health perspective, Science 221 (4605);1993. p.9-17
  38. Sterling TD. Concentrations of nicotine, RSP, CO and $CO^{2}$ in non-smoking areas of offices ventilated by air recirculated from smoking designated areas. American Industrial Hygiene Association Journal 1991;52(10): 564-565
  39. Stewart RD, Peterson JE, Baretta ED, Bachand RT, Hosko MJ, Herrmann AA. Experimental human exposure to carbon monoxide. Archives of Environmental Health 1970;21(2): 154-164
  40. Stolwijk JA. Risk assessment of acute health and comfort effects of indoor air pollution. Annals of the New York Academy of Sciences 641, p.56-62
  41. U.S. Environmental Protection Agency (EPA), Risk assessment guidance for superfund(RAGS) : volume I. human health evaluation manual(HHEM), Office of emergency and remedial response, EPA/540/1-89/002, 1989
  42. U.S. Environmental Protection Agency (EPA), Volume I-General factors handbook, Exposure factors handbook, updated to 1989 Exposure factors handbook, National Center for Environmental Assessment, EPA/600/P-95/--2Fa, Chapter I and V, 1997