Development of Biosignal Telemonitoring SystemBased on HL7 and MFER Standard

HL7 과 MFER 표준을 이용한 원격생체정보 공유 기술 개발

Kim, Jae-Pil;Choe, Myeong-Seon;Park, Hui-Gyeong;Choe, Jin-Uk
김재필;최명선;박희경;최진욱

  • Published : 20040000

Abstract

Objective: We developed a biosignal telemonitoring system which is based on HL7 and MFER standard. Methods: For the communication of waveform data (ECG, EEG etc.) we adopted MFER(Medical waveform description Format Encoding Rules) standard and HL7(Health Level 7). MFER is a standard for encoding waveform biosignal such as ECG, EEG and so on. HL7 is a standard for electronic data communication between two different information systems. Results: The telemornitoring system consists of an HL7 interface gateway and a central repository. The HL7 interface gateway has three modules of an MFER analyzer, an HL7 message generator, and a file sender. The central repository is a central database combined with an HL7 archiver. Conclusion: Through this study we might conclude that the proposed system can be a promising model for telemonitoring system in healthcare environment.

Keywords

References

  1. Chan A. Integrating smart card access to web-based medical information system. Proceedings of the 2003 ACM Symposium on Applied Computing;2003 March 09-12; New York, USA
  2. Chen ES, Mendonca EA, Mcknight LK, Stetson PD, Lei J, Cimino JJ. Palm CIS: a wireless handheld application for satisfying clinician information needs. Journal of the American Medical Information Association 2003;11(1):19-19
  3. Kohn L, Corrigan J, Donaldson M. To err is human: building a safer health system. Washington, D.C:National Academy Press;1999. pp. 22-23
  4. Institute Of Medicine. Crossing the quality chasm: a new health system for the 21st century. Washington, D.C: National Academy Press;1999. pp. 23-25
  5. Kim BY, Choi JW. A web-based pulse wave information management system. Journal of Korean Society of Medical Informatics 2002;8(3):51-52
  6. Lee SH, Shin JW, Sung HM Yoon YR, Lee KJ. A study on the development of integrated biosignal management system. Journal of Korean Society of Medical Informatics 1998;4(2):20-21
  7. MFER(Medical waveform Format Encoding Rule) Committee. Medical waveform description format encoding rule MFER Part I (Ver1.01-2003). Tokyo Japan:MFER Committe;2003. pp. 2-3
  8. Available at: http://www.hl7korea.org/standard/intro_s.htm. Accessed October 4, 2004
  9. Korea Health Industry Development Institute. Introduction to health level seven (HL7). Seoul:Moonyoung-sa;2002. pp.22-25
  10. Available at: http://www.orionhealth.com/symphonia_technical_general.htm. Accessed October 4, 2004
  11. Davis R. Win32 Network programming. Massachusetts (NE):Addison Wesley;1996. pp.243-245
  12. Health Level Seven Inc. Health level seven standard II (ver.2.3). Ann Arbor (MI):HL7 Inc;1997. pp. 66-67