Nondestructive Testing and Applications for Electric Power Plant Equipments by Acoustic Emissin Technology

음향방출기술에 의한 발전설비 비파괴검사 및 응용

  • Published : 2004.08.30

Abstract

Diagnosis f structural integrity is the basis for correct treatment of and countermeasures against progressive structural abnormalities. An exact diagnosis is at present the most reliable means for determining the soundness of structures during power plant operations. Acoustic emission(AE) technology has recently strengthened its application base, and practitioners' understanding of the technique's fundamentals. This paper presents the results of a survey and assessment on AE monitoring applications in nuclear, fossil and hydraulic power plant. The main objective of this paper was to obtain information on various applications of AE technology in electric power plant.

음향방출기술(acoustic emission technology)은 종래의 기존 비파괴검사법과는 달리 가동중인 설비의 건전성을 평가할 수 있으며 실시간으로 설비 상태의 진단이 가능한 실시간 감시기법이다. 즉 기존 비파괴검사법과는 달리 가동중인 설비에 대해 원격으로 결함을 탐지하고 결함 위치를 판정할 수 있는 연속감시 기능을 가진 비파괴 신기술로 최근 연구개발이 활발히 진행되고 있는 방법이다. 이러한 장점 때문에 대형 산업설비의 각종 기기들에 대한 감시 및 진단에 활용하고 있으며, 그 활용도가 점점 확대되고 있는 추세에 있다. 특히 종합적인 산업설비로 구성되어 있는 발전설비의 진단과 감시에 가장 효과적인 방법이라 할 수 있겠다. 본 논문에서는 원자력 화력 수력발전소 등의 발전설비에 대해 현재 적용중인 음향방출기술과 새로운 적용기술에 대해 서술하였다.

Keywords

References

  1. S. P. Ying, 'The Use of Acoustic Emission for Assessing the Integrity of a Nuclear Reactor Pressure Vessel,' NDT International, pp. 175-179, (1979)
  2. 원자로 감시설비, 한국전력공사 연구보고서, (1997)
  3. Nondestructive Testing handbook, Vol. 5, Acoustic Emission Testing, pp. 226-259, (1987)
  4. T. Yoneyama, I. Sato and M. Yanagibashi, 'Machine Condition Diagnosis Using Acoustic Emission Techniques,' 非破壞檢査, Vol. 44, No.1, pp. 20-26, (1995)
  5. I. Sato, 'Rotating Machinery Diagnosis with Acoustic Emission Techniques,' T. IEE Japan, Vol. 109, No.3, pp. 145-152, (1989)
  6. I. Sato, T. Yoneyama, S. Sasaki and T. Sasaki, 'Rotating Machinery Diagnosis with Acoustic Emission Techniques,' J. of Acoustic Emission, Vol. 2 , No. 1/2, pp. 1-10, (1983)
  7. A. F Armor, J. R Scheibel and M. A. Blanco, 'Diagnostic Monitoring of Power Plants The Key to Predictive Maintenance,' EPRI Report, (1990)
  8. R. L. Leon and J. R. Scheibel, 'Current Status of the EPRI Acoustic Doppier Blade Monitor,' Third EPRI Incipient Failure Detection Conference, Proceedings CS-5395, (1988)
  9. I. Inam, J. R. Scheibel, et al. , 'Development and Application of an On-Line Rotor Crack Detection and Monitoring System,' Third EPRI Incipient Failure Detection Conference, Proceedings CS-5395, (1988)
  10. Acoustic Boiler Tube Leak Detection Utility Experience, CS-5136 EPRI Final Report, (1987)
  11. Acoustic Emission Monitoring of Cracks in Fossil Fuel Boiler, CS-5264 EPRl Final Report, (1987)