Aroma Pattern Analysis of Hanwoo Beef (M. longissimus) using Electronic Nose during Refrigerated Storage

전자 코를 이용한 한우 등심육의 냉장저장 중 향기 패턴 분석

  • 이성기 (강원대학교 축산식품과학과) ;
  • 김주용 (매일유업주식회사) ;
  • 김용선 (강원대학교 동물자원공동연구소)
  • Published : 2004.09.01

Abstract

This study was carried out to investigate aroma patterns of Hanwoo (Korean cattle) beef using electronic nose during refrigerated storage, and to compare these results with chemical quality (pH, TBARS). The M. longissimus muscle from Hanwoo carcasses after 24 hrs postmortem was obtained and stored at 5${\pm}$1$^{\circ}C$ for 7 days. Sensitivity (dR/RO) values among electronic nose data were changed differently during refrigerated storage, and showed significant difference on the 7th day of storage (p<0.01). The dR/RO from SY/G, SY/AA, SY/Gh, SY/gCTl, SY/gCT decreased but those from SY/LG, T30/1, P10/1, P10/2, P40/1, T70/2, PA2 increased during storage for 7 days. Mapping these data using PCA (principal component analysis) showed that the 1st day data were present in the middle of the right side, the 3rd day data were present in bottom part of this area and the 7th day data spread out more widely on the left side. In case of DFA (discriminant factor analysis), the flock clustered round and located in different side clearly comparing with PCA plot. In analysis of correlation coefficients among electronic nose data and chemical quality data, there was significant correlation among sensor data (p<0.001). But pH and TBARS were not significantly correlated with electronic nose data. Consequently, PCA and DFA plot by electronic nose data showed difference during refrigerated storage and there were significant correlations among sensors. Therefore it will be possible to detect separate aroma patterns of Hanwoo beef using electronic nose.

본 연구는 전자 코 시스템을 이용하여 센서의 감응도, 주성분 분석, 판별분석을 통해 한우육의 향기 패턴을 구명하고, 이를 pH 및 TBARS 값과 비교함으로써 쇠고기의 신속한 향기 평가방법의 가능성을 모색하기 위해 실시하였다. 시료는 도축 후 24시간이 경과한 쇠고기의 등심을 5$\pm$1$^{\circ}C$에서 7일간 저장하면서 실험에 사용하였다. 저장기간이 증가함에 따라 SY/G, SY/AA, SY/Gh, SY/gCTl, SY/gCT 센서의 감응도(dR/R0) 값은 감소하였으나, SY/LG, T30/1, P10/1, P10/2, P40/1, T70/2, PA2 센서의 dR/R0 값은 증가하였다. 저장 1일과 3일째에서는 dR/R0 값이 SY/AA#, T70/2 센서에서만 유의적인 차이를 보였으나(p<0.05), 저장 7일째에서 저장1일과 비교하였을 때 12개의 센서가 모두 유의적인 차이를 보였다(p<0.05). 감응도의 결과를 주성분 분석으로 mapping 하였을 때 저장 1일에 오른쪽 중간, 3일에 오른쪽 하단, 7일에 왼쪽에 길게 퍼져 군락이 형성되었다. 다시 판별분석으로 mapping을 하면 동일 저장기간내 군락이 집중되고, 저장기간별 군락군이 분산되어 뚜렷하게 구별되었다. 저장기간동안 육의 pH와 TBARS는 모두 어떤 항목과도 상관성을 보이지 않았으나, 모든 센서의 값이 각각 정 또는 역의 높은상관성을 가지고 있었다(p<0.001).

Keywords

References

  1. Anonymous (2001) Semi-conduct Sensors. Alpha MOS Co. France
  2. Amold, J. W. and Senter, S. D. (1998) Use of digitalaroma technology and SPME GC-MS to compare volatile compounds produced by bacteria isolated from processed poultry. J. Sci. Food & Agric. 78, 343-348 https://doi.org/10.1002/(SICI)1097-0010(199811)78:3<343::AID-JSFA124>3.0.CO;2-5
  3. Blixt, Y. and Borch, E. (1999) Using an electric nose for determining the spoilage of vacuum-packaged beef. International J. Food MicrobioI 46, 123-134 https://doi.org/10.1016/S0168-1605(98)00192-5
  4. David, C. L., Don, A. B., and Graham, A. B. (1998) Electronic noses. In: Prospects for applications in Australian industry. Jain, L. C. and Jain, R. K.(eds), Proceeding of the Second International Conference on Knowledge- Based Intelligent Electronic Systems, 21-23 April 1998. pp. 126
  5. Grigioni, G. M., Margaria, C. A., and Pensel, N. A. (2000) Aroma of fresh and processed meat assessed by an electronic nose. Proceed. 46th Int. Cong. Meat Sci. Technol, Buenos Aires, Argentina, Vol. 2, pp. 591
  6. Hall, M. (1997) Assistance of electric noses at meat inspection. Svensk-Veterinartidinng 49(8/9), 375-378
  7. Harper, W. J. (2000) Newer methods in sensory analysis. Proceed. 46th Int. Cong. Meat Sci. Technol., Buenos Aires, Argentina, Vol. 2, pp. 582-589
  8. MacLeod, G. (1994) The flavor of beef. In: Flavor of meat and meat products. Shahidi, F. (ed), Blackie Academic & Professional, London, pp. 4-37
  9. Masila, M., Breimer, M., and Sadik, 0. A. (1999) Strategies for improving the analysis organic compounds using GC-Based electronic nose. In: Electronic nose and sensor array based systems. Hurst, W. J. (ed), Proceedings of 5th International Symposium on Olfaction and Electronic Nose, pp. 27
  10. Neuman, D. J., Luzuriage, D. A., and Balaban, M. 0. (1999) Odor and microbiological evaluation of raw tuna. In: Electronic noses and sensor array based systems - Design and application. Technomic Publishing Company, Lancaster, Basal, pp. 170-176
  11. SAS (1995) SAS/STAT Software for PC. Release 6.11, SAS Institute Inc., NC, USA
  12. Sinnhuber, R. 0. and Yu, T. C. (1977) The 2-thiobar-bituric acid reaction, and objective measure of the oxidative deterioration occurrmg in fats and oils. J. Jap. Soc. Fish. Sci. 26, 259-267
  13. Vincent, D. (1999) Electronic nose: principal and application. Nature 402. 351-352 https://doi.org/10.1038/46421
  14. 인성(주) (2001) 전자 코/전자 혀 system의 원리와 응용. Workshop 자료. 서울