Abstract

Impingement/effusion cooling technique is used for combustor liner or turbine parts cooling in gas turbine engine. In the impingement/effusion cooling system, the crossflow generated in the cooling channel induces an adverse effect on the cooling performance, which consequently affects the durability of the cooling system. In the present study, to reduce the adverse effect of the crossflow and improve the cooling performance, circular pin fins are installed in impingement/effusion cooling system and the heat transfer characteristics are investigated. The pin fins are installed between two perforated plates and the crossflow passes between these two plates. A blowing ratio is changed from 0.5 to 1.5 for the fixed jet Reynolds number of 10,000 and five circular pin fin arrangements are considered in this study. The local heat/mass transfer coefficients on the effusion plate are measured using a naphthalene sublimation method. The results show that local distributions of heat/mass transfer coefficient are changed due to the installation of pin fins. Due to the generation of vortex and wake by the pin fin, locally low heat/mass transfer regions are reduced. Moreover, the pin fin prevents the wall jet from being swept away, resulting in the increase of heat/mass transfer. When the pin fin is installed in front of the impinging let, the blockage effect on the crossflow enhances the heat/mass transfer. However, the pin fin installed just behind the impinging jet blocks up the wall jet, decreasing the heat/mass transfer. As the blowing ratio increases, the pin fins lead to the higher Sh value compared to the case without pin fins, inducing $16\%{\~}22\%$ enhancement of overall Sh value at high blowing ratio of M=1.5.

Keywords

References

  1. Hollwarth, B. R. and Dagan, L., 1980, 'Arrays of Impinging Jets with Spent Fluid Removal through Vent Holes on the Target Surface Part 1: Average Heat Transfer,' J. of Engineering for Power, Vol. 102, pp. 994-999 https://doi.org/10.1115/1.3230372
  2. Hollwarth, B. R., Lehmann, G. and Rosiczkowski, J., 1983, 'Arrays of Impinging Jets with Spent Fluid Removal through Vent Holes on the Target Surface Part 2: Local Heat Transfer,' J. of Engineering for Power, Vol. 105, pp. 393-402 https://doi.org/10.1115/1.3227428
  3. Cho, H. H. and Goldstein, R. J., 1996, 'Effect of Hole Arrangements on Impingement! Effusion Cooling,' Proceeding of the 3rd KSME-JSME Thermal Engineering Conference, pp. 71-76
  4. Cho, H. H. and Rhee, D. H., 2001, 'Local Heat/Mass Transfer Measurement on the Effusion Plate in Impingement/Effusion Cooling System,' J. of Turbomachinery, Vol. 123, pp. 601-608 https://doi.org/10.1115/1.1344904
  5. Cho, H. H., Choi, J. H. and Rhee, D. H., 2001, 'The Effects of Hole Arrangements on Heat/Mass Transfer of Impingement/Effusion Cooling System,' Proceedings of ExHFT-5, pp. 975-980
  6. Yoon, P. H., Rhee, D. H. and Cho, H. H., 2001, 'Flow and Heat/Mass Transfer Characteristics of Arrays of Impingement Jets with Effusion Holes,' Trans of the KSME (B), Vol. 25, No. 11, pp. 1606-1615
  7. Metzger, D. E. and Korstad, R. J., 1992, 'Effects of Cross Flow in Impingement Heat Transfer,' J. of Engineering for Power, Vol. 94, pp. 35-41
  8. Florschuetz, L. W., Metzger, D. E. and Su, C. C., 1984, 'Heat Transfer Characteristics for Jet Array Impingement With Initial Crossflow,' J. of Heat Transfer, Vol. 106, pp. 34-41 https://doi.org/10.1115/1.3246656
  9. Haiping, C., Wanbing, C. and Taiping, H., 1999, '3-D Numerical Simulation of Impinging Jet Cooling with Initial Crossflow,' ASME Paper No. 99-GT-256
  10. Yoon, P. H., Rhee, D. H. and Cho, H. H., 2000, 'Effect of Arrays of Impinging Jet with Cross flow on Heat/Mass Transfer,' Trans of the KSME (B), Vol. 24, No. 2, pp. 195-203
  11. Rhee, D. H., Choi, J. H. and Cho, H. H., 2002, 'Flow and Heat (Mass) Transfer Characteristics in an Impingement/Effusion Cooling System with Crossflow,' J. of Turbomachinery, Vol. 125, pp. 74-82 https://doi.org/10.1115/1.1519835
  12. Haiping, C, Dalin, Z., Dong, H. and Taiping, H., 1996, 'Experimental Investigation on Impingement Heat Transfer from Rib Roughened Surface Within Arrays of Circular Jet: Effect of Geometric Parameters,' ASME Paper No. 98-GT-208
  13. Gau, C. and Lee, C. C., 1992, 'Impingement Cooling Flow Structure and Heat Transfer Along Rib-Roughened Walls,' Int. J. of Heat Mass Transfer, Vol. 35, pp. 3009-3020 https://doi.org/10.1016/0017-9310(92)90320-R
  14. Rhee, D. H., Nam, Y. W. and Cho, H. H., 'Heat/Mass Transfer Characteristics on Rib-roughened Surface for Impingement/Effusion Cooling System with Initial Crossflow,' Trans of the KSME (B), Vol. 28, No. 3, pp. 338-348
  15. Cho, H. H. and Goldstein, R. J., 1995, 'Heat (Mass) Transfer and Film Cooling Effectiveness with Injection Through Discrete Holes Part I: Within Holes and on the Back Surface,' J. of Turbomachinery, Vol. 117, pp. 440-450 https://doi.org/10.1115/1.2835680
  16. Goldstein, R. J. and Cho, H. H., 1995, 'A Review of Mass Transfer Measurement Using Naphthalene Sublimation,' Experimental Thermal and Fluid Science, Vol. 10, pp. 416-434 https://doi.org/10.1016/0894-1777(94)00071-F
  17. Eckert, E. R. G., 1976, 'Analogies to Heat Transfer Processes,' in Measurements in Heat Transfer, ed. Eckert, E. R. G. and Goldstein, R. J., pp. 397-423, Hemisphere Pub., New York
  18. Kline, S. J. and McClinetock, F., 1953, 'Describing Uncertainty in Single Sample Experiments,' Mechanical Engineering, Vol. 75, pp. 3-8