Analysis of Heat Transfer Characteristics in Soil for Development of a Geothermal Heat Exchange System

지열 열교환시스템 개발을 위한 지중 열유동 특성분석

  • Lee Y. B. (National Institute of Agricultural Engineering) ;
  • Cho S. I. (Seoul National University) ;
  • Kang C. H. (Bio-Production Fundamental Engineering Division) ;
  • Jung I. K. (National Institute of Agricultural Engineering, RDA) ;
  • Lee C. G. (National Institute of Agricultural Engineering, RDA) ;
  • Sung J. H. (National Institute of Agricultural Engineering, RDA) ;
  • Chung S. O. (National Institute of Agricultural Engineering, RDA) ;
  • Kim Y. B. (GyeongSang National University)
  • Published : 2005.06.01

Abstract

Importance of alternative energy has been increasing due to environmental issues and lack of fossil fuels. In addition, heating cost that occupies from 30 to $40\%$ of the total production cost in the protected cultivation sector in Korea needs to be reduced for profitability and global competition. But, study on geothermal energy to solve these problems has not been activated for Korean protected cultivation. This study was conducted to develop an optimized geothermal exchange system through fundamental test of heat transfer characteristics in soil such as thermal diffusivity, changes in soil temperature during heating and cooling operations, and restorations of soil temperature after the heater was fumed off, These issues were investigated using computer simulation for different depths. The simulated characteristics were evaluated through controlled tests. Simulated characteristics of heat transfer in the soil at different depths showed a reasonable agreement with the results of the controlled tests. All of computer simulation and controlled tests, soil temperatures changed at 10cm and 20cm distance from pipe. but don't change at more than 30cm distance. It means that distances of heat transfer of the soil ranged from 20 to 30cm a day. Based on these results, the optimum spacing between adjacent heat exchange pipes and the pitch were selected as 50 and 40cm, respectively.

Keywords

References

  1. Fluent Inc. 1998. Fluent5 users guide : 6-13
  2. Holman, J. P. 1986. Heat transfer. New York:McGraw-Hill
  3. Kim, Y. B., L. Baeg. 1996. Performance analysis of an earth tube heat exchanger (I) - Temperature variation characteristics and heat exchange performance on the mode of continuous operation-. Journal of the KSAM 21(4):436-448. (In Korean)
  4. Puri, V. M. 1986. Feasibility and performance curves for intermittent earth-tube heat exchangers. Trans. of the ASAE 29(2):525-532
  5. Puri. V. M. 1987. Earth-tube heat exchanger performance correlation using boundary element method. Trans. of the ASAE 30(2):514-520 https://doi.org/10.13031/2013.31980
  6. 高倉, 山川健一. 1991. 地中熱交換方式の暖房效果と運用上の問題點. 農業施設 12:41-47