A Case Study on the Economic Analysis for an Advanced Technology-Based HYAC System Using LCC Technique

LCC 기법을 이용한 신기술 냉 $\cdot$ 난방 공조설비 시스템의 경제성 분석에 관한 사례연구

  • Published : 2005.04.01

Abstract

The purpose of this study is to assess economic effects for an advanced technology-based HVAC system. The study has been performed using LCC technique for the economic analysis. Data for LCC analysis are collected from estimation and interview of estimators and maintenance experts of buildings. Based on the LCC analysis, the economic effect of a new HVAC system has been predicted as follows : for the investment during 15 years of study period, (1) $21.6\%$ of LCC saving is predicted, (2) return rate for the investment is 4.8 times in case of new construction, and 14.4 times in case of building remodelling.

본 연구는 LCC 기법을 이용한 냉 $\cdot$ 난방 공조설비 시스템에 대하여 사업 실행전 LCC와 사업 실행후 LCC를 예측, 성과측정 및 경제성 평가를 목적으로 진행되었다. 이를 위해 신기술 냉 $\cdot$난방 공조설비 시스템의 Life Cycle동안의 비용자료를 실적자료와 견적자료, 인터뷰등의 방법으로 조사 $\cdot$ 분석하였다. 또한 분석기간 15년 동안의 사업 실행전 $\cdot$ 후의 LCC를 예측하여 성과측정 및 경제성 평가를 실시하였다. 이와 같은 과정을 통해 수행된 본 연구의 결과는 다음과 같다: 1)일체형 개별냉 $\cdot$난방공조설비의 설치로 인해 할인비용시 $21.6\%$의 경제성이 있는 것으로 분석되었다. 3)성과측정은 투자대비 회수배율로서 할인비용시 회수배율은 신축의 경우 4.8배, 리모델링의 경우 14.4배의 경제성이 있는 것으로 분석되었다.

Keywords

References

  1. 강창희, LCC 기법을 이용한 ESCO 사업의 성과측정에 관한 연구, 중앙대학교 석사학위논문, 2002
  2. 김용수, 아파트 건물의 수명주기비용 예측을 위한 운영관리 비 분석 및 예측모델의 개발, 대한건축학회논문집 구조계 제 14권 10호, 1998
  3. 박민용, 라이프 사이클 코스트 기법을 이용한 냉열원 방식의 경제성 평가, 대한건축학회 논문집 계획계, 1998, 10
  4. 정종림, LCC 분석에 의한 고층건물 설비시스템의 대안평가, 대한 건축학회 논문집 계획계, 2003. 1