Application of Electrical Resistivity Monitoring Technique to Maintenance of Embankments

저수지의 유지관리를 위한 전기비저항모니터링 기법 응용

  • Park Sam Gyu (Geotechnical Engineering Division, Korea Institute of Geoscience and Mineral Resources(KIGAM)) ;
  • Kim Jung-Ho (Geotechnical Engineering Division, Korea Institute of Geoscience and Mineral Resources(KIGAM)) ;
  • Seo Goo Won (Korea Agricultural & Rural Infrastructure Corporation(KARICO))
  • 박삼규 (한국지질자원연구원 지반안전연구부) ;
  • 김정호 (한국지질자원연구원 지반안전연구부) ;
  • 서구원 (농어기반공사)
  • Published : 2005.05.01

Abstract

The subject of this paper is research into the application of electrical resistivity monitoring to detecting the water leakage of water utilization facilities. For this purpose, we installed a comprehensive monitoring system consisting of resistivity measurement, inclinometer, piezometer, and water gauge at an embankment. Using this monitoring system, we monitored the various kinds of measurement data and compared the resistivity structures and that of hydrological and engineering data in order to investigate the water leakage and stability of the embankment. The variant images of electrical resistivity at the embankment were provided from the monitoring data and we could accurately locate the portion of which resistivities have sharply changed. Furthermore, we could estimate the stability of the embankment more effectively and quantitatively by jointly interpreting the monitoring data of resistivity, water level, pore water pressure, and subsurface displacement. The monitoring experiments in this study led us to the conclusion that for the efficient maintenance of the water utilization facilities, monitoring the resistivity data and hydrological data would be much more preferable to performing the just one-time measurements.

이 논문에서는 수리시설물을 효율적으로 유지관리하기 위하여 저수지 제체에 계측 시스템을 설치하고, 전기비저항, 수위, 간극수압 및 지중변위를 주기적으로 모니터링하여 그 결과를 분석함으로써 제체의 누수현상 및 안정성 평가를 시도하였다. 저수지 제체의 댐마루에 설치된 전기비저항 측정 시스템으로부터 측정한 각 단계별 전기비저항의 변화영상을 구하고, 변화추이를 비교분석함으로써 누수현상을 정확하게 파악할 수 있었고, 수위, 간극수압 및 지중변위량의 자료를 종합적으로 해석함으로써 제체의 안정성을 평가할 수 있었다. 이러한 결과로부터 종래의 일시적으로 실시한 전기비저항탐사 결과로부터 누수현상을 파악하는 것보다 전기비저항 등 모니터링 계측시스템을 설치하여 운용하는 것이 수리시설물을 효율적이고 경제적으로 유지관리하기 위한 방법임을 알았다.

Keywords