Hydrogeological Properties of Uunconsolidated Formations and Bedrocks in the Central Area of Busan Metropolitan City

부산 도심지역 미고결층과 기반암의 수리지질 특성

  • Published : 2005.12.01

Abstract

This study aims to investigate hydrogeological properties of the central area from Yangjeong-Dong to Sujeong-Dong in Busan Metropolitan City. For this study, pumping tests were carried out in the bedrock aquifer of Yangjeong-Dong and the unconsolidated aquifer near Busanjin railway station. The pumping test in the bedrock aquifer containing the Dongrae fault revealed specific hydraulic characteristics with respect to the fault. The pumping test in the unconsolidated aquifer revealed the hydrogeologic properties of both coastal landfill and fine sediments. It was found that the Moench's sphere-shaped dual-porosity model fits the bedrock aquifer, whereas the Neuman's uncofined aquifer model accords with the unconsolidated aquifer. The average transmissivity and storage coefficient of the bedrock aquifer are $2.75{\times}10^{-5}m^2/s\;and\;6.41{\times}10^{-5}$ and those of the unconsolidated aquifer are $8.24{\times}10^{-4}m^2/s\;and\;3.70{\times}10^{-3}$, respectively. On the other hand, slug tests gave average transmissivity and storage coefficient values of $9.84{\times}10^{-4}m^2/s\;and\;1.21{\times}10^{-2}$, respectively.

본 연구는 부산광역시 도심지역 중 부산진구 양정동부터 동구 수정동까지 지역에 대한 수리지질 특성을 파악하였다. 이를 위하여 양정동의 암반대수층과 부산진구 부산진역 부근의 미 고결층에서 양수시험을 실시하였다. 특히 양정동의 암반대수층은 동래단층대와 만나는 지 역으로서 동래단층의 수리지 질 특성을 파악하는데 중점을 두었고, 부산진구 부산진역 부근의 미고결층에서 행한 양수시험에서는 해안매립지와 해안퇴적층(미고결층)의 수리지질 특성을 파악하였다. 양정동의 암반대수층에 대해서는 Moench의 구상체 이중공극모델이 적합한 것으로 나타났으며, 부산진역 부근의 미고결층에 대해서는 Neuman의 자유면대수층 모델이 적당한 것으로 나타났다. 암반대수층의 평균 투수량계수는 $2.75\times10^{-5}m^2/s$, 평균 저류계수는 $6.41{\times}10^-5}$이고, 미고결층의 투수량계수는 $8.24\times10^{-4}m^2/s$, 저류계수는 $3.70\times10^{-3}$이다. 한편 순간충격 시험에 의한 평균 투수량계수와 평균 저류계수는 각각 $9.84{\times}10^{-4}m^2/s\;와\;1.21{\times}10^-4}$이다.

Keywords

References

  1. 김정숙, 1999, 부산 금정지역 지하수의 수리지구화학적 특성 연구, 부산대학교 대학원 이학석사 학위논문, 74p
  2. 성익환, 이병대, 조병욱, 류충렬, 김경수, 이춘오, 이봉주, 임현철, 이병대, 지세정, 김용욱, 성기성, 박덕원, 이대하, 김중렬, 현혜자, 김유성, 항세영, 윤선, 김학준, 1999a, 금정터널지하수 유동체계 분석 및 동래온천지역 영향평가, 한국자원연구소, 443p
  3. 성익환, 조병욱, 이병대, 지세정, 류충렬, 김통권, 윤욱, 이봉주, 임현철, 이종철, 이병태, 김경구, 성기성, 이인호, 추창오, 김정숙, 김문수, 최경국, 함세영, 최광선, 김인수, 조명회, 심형수, 원지훈, 정상용, 박희영, 강동환, 심명환, 김명우, 1999b, 지하수 오염방지 및 음용화 기술연구(부산지역), 한국자원연구소, 541 p
  4. 심병완, 2003, 부산 동남해안 지역의 수리동역학적 해수침투 특성연구, 부경대학교 일반대학원 이학박사 학위논문, 123 p
  5. 정상용, 권해우, 이강근, 김윤영, 1997, 부산 석대 폐기물 매립지 일원의 수질 환경, 지하수환경, 4권 4호, 175-184
  6. 조명희, 1999, 부산 남부지역 안산암질암 지하수 및 서북부지역 화강암 지하수의 수질 특성 비교연구, 부산대학교 대학원 이학석사 학위논문, 103 p
  7. 함세영, 1999, 구상체 및 판상체 이중공극 프락탈 매체내 지하수 유동, 지질학회지, 35권 2호, 137-146
  8. 함세영, 조명희, 성익환, 김정숙, 이병대, 조병욱, 한석종, 1999, 부산 북서부 화강암지역 지하수의 화학적특성, 수처리기술, 7권 2호, 57-68
  9. 함세영, 조명희, 황진연, 김진섭, 성익환, 이병대, 2000, 부산 금정산-백양산 일대 용천수, 지하수 및 지열수의 지화학적 특성, 한국환경과학회지, 9권 3호, 229-239
  10. 함세영, 김문수, 성익환, 이병대, 김광성, 2001, 순간충격시험에 의한 화강암지역의 수리적 매개변수 산출, 지질공학, 11권 1호, 63-79
  11. Barenblatt, G.E., Zheltov, I.P. and Kochina, I.N., 1960, Basic concepts in the theory of seepage of homogeneous liquids in fissured rocks, Jour. Appl. Math, Mech. Engl. Transl.,24(5), 1286-1303
  12. Boulton, N.S. and Streltsova, T.D., 1977, Unsteady flow to a pumped well in a fissured water-bearing formation, J. Hydrol., 35, 257-269 https://doi.org/10.1016/0022-1694(77)90005-1
  13. Bower. H. and Rice, R.C., 1976, A slug test for determining hydroaulic conductivity of unconfined aquifers with completely or partially penetrating wells, Water Resour. Res., 12(3),423-428 https://doi.org/10.1029/WR012i003p00423
  14. Butler, J.J., Jr., McElwee, C.D., and Liu, W., 1996, Improving the quality of parameter estimates obtained from slug tests, Ground Water, 34(3), 480-490 https://doi.org/10.1111/j.1745-6584.1996.tb02029.x
  15. Butler, J.J., 1998, The design, performance, and analysis of slug tests, Lewis publishers, 252 p
  16. Cho, B.W., 2001, Hydrogeological Characteristics of the Groundwater Resources in the Busan Area, Korea, doctoral thesis of Kyungpook National University, 164 p
  17. Cooper, H.H., Jr., Bredehoeft, J. D., and Papadopulos, I. S. 1967, Respose to a finite diameter well to an instantaneous charge of water. Water Resour. Res., 3, 263-269 https://doi.org/10.1029/WR003i001p00263
  18. Gringarten, A.C. and Witherspoon, P.A., 1972, A method of analyzing pump test data from fractured aquifers, Proc. Symp. Rock Mechanics, Int. Soc. Rock Mechanics and Int. Assoc. Eng. Geol., Stuttgart, 3-B, p. 1-9
  19. Gringarten, A.C. and Rammy, H.J., 1974, Unsteady state pressure distributions created by a well with a single horizontal fracture, partial penetration or restricted entry, Soc. Petrol. Engrs. J., 263-269
  20. Han, S. J., Hamm, S.-Y., Sung, I. H., Lee, B. D., Cho, B. W., and Cho, M. H, 1999, Geochemical Characteristics of Geothermal Water and Groundwater in the Dongrae hot-spring Area, Eng. Ceol., 9(3), 207-225
  21. Hantush, M.S., 1960, Modification of the theory of leaky aquifers, J. Ceophy. Res., 19(4), 1019-1035
  22. Hantush, M.S., and Jacob, C.E., 1955, Non-steady radial flow in an infinite leaky aquifer, Am. Ceophys. Union Trans., 36, 95-100 https://doi.org/10.1029/TR036i001p00095
  23. Hvorslev, M.J., 1951, Time lag and soil permeability in ground water observations, U. S. Army Corps of Engineers Waterway Experimentation Station, Bulletin 36, 50 p
  24. Kazemi, H., 1969, Pressure transient analysis of naturally fractured reservoirs with uniform fracture distributions, Trans. Soc. Pet. Eng. AlME, 246, 451-462
  25. McElwee, C.D., Bohling, C.C., and Butler, Jr., J.J., 1995a, Sensitivity analysis of slug tests. Part 1. The slugged well, J. Hydrol., 164, 53-67 https://doi.org/10.1016/0022-1694(94)02568-V
  26. McElwee, C.D., Bohling, C.C,, and Butler, Jr., J.J., 1995b, Sensitivity analysis of slug tests. Part 2. Observation wells. J. HydroL, 164, 69-87 https://doi.org/10.1016/0022-1694(94)02569-W
  27. Moench, A.F., 1984, Double-porosity models for a fissured groundwater reservoir With fracture skin, Water Resour. Res., 20, 831-846 https://doi.org/10.1029/WR020i007p00831
  28. Moench, A.F., 1985, Transient flow to a large-diameter well in an aquifer with storative semiconfining layers, Water Resour. Res., 21(8), 1121-1131 https://doi.org/10.1029/WR021i008p01121
  29. Neuman, S.P., 1975, Analysis of pumping test data from anisotropic unconfined aquifers considering delayed gravity response, Water Resour. Res., 11, 329-342 https://doi.org/10.1029/WR011i002p00329
  30. Neuman, S.P., and Witherspoon, P.A., 1969, Theory of flow in a confined two aquifer system, Water Resour. Res., 5(4), 803-816 https://doi.org/10.1029/WR005i004p00803
  31. Papadopulos, I.S. and Cooper, H.H., 1967, Drawdown in a well of large diameter, Water Resour. Res., 3(1), 241-244 https://doi.org/10.1029/WR003i001p00241
  32. Sauty, J.-P. and Kinzelbach, W., 1992, CATTI, IGWMC-BAS 24 PC, Ver. 3.01E, 63 p
  33. Stehfest, H., 1970, Algorithm 368, Numerical inversion of Laplace transforms, Commun. ACM, 13(1),47-49 https://doi.org/10.1145/361953.361969
  34. Theis, C.v., 1935. The relation between the lowering of the piezometric surface and the rate and duration of discharge of a well using groundwater storage, Am. Ceophys. Union Trans., 16, 519-524 https://doi.org/10.1029/TR016i002p00519
  35. Warren, J.E. and Root, P.J., 1963, The behavior of naturally fractured reservoirs, SPEJ, 3(2), 245-255 https://doi.org/10.2118/426-PA