Structural Analysis of Liquid Rocket Thrust Chamber Regenerative Cooling Channel at Room Temperature

액체로켓 연소기 재생냉각 채널 상온 구조해석

  • 류철성 (한국항공우주연구원 연소기그룹) ;
  • 정용현 (한국항공우주연구원 엔진그룹) ;
  • 최환석 (한국항공우주연구원 연소기그룹) ;
  • 이동주 (충남대학교 기계공학과)
  • Published : 2005.12.01

Abstract

The structural analysis and water pressure tests are performed for liquid rocket thrust chamber regenerative cooling channel specimens at room temperature condition. Material properties of copper alloy to be used in the elastic-plastic structural analysis are obtained by uniaxial tension test at room temperature. The plate-type cooling channel specimens are manufactured and performed water pressure test to verify the analysis results. The results of elastic-plastic structural analysis and water pressure test show resonable agreements though with minor differences and it is revealed that structural stability of regenerative cooling channel is highly affected by the manufacturing tolerances due to very thin cross-sectional thickness of the cooling channel.

재생냉각형 액체로켓 연소기 챔버 냉각 채널부의 상온상태의 구조해석과 검증시험을 수행하였다. 재생냉각 연소기 냉각 채널부에 사용하는 구리 합금의 상온 인장시험을 수행하여 재료의 탄소성 물성 값을 확보하였으며 냉각 채널의 탄-소성해석은 이 물성 값을 이용하여 수행하였다. 해석결과의 검증을 위해서 평판형태의 냉각채널 시편을 제작하여 강도시험을 수행하였다. 탄-소성 구조해석 결과와 시편의 수압시험 결과 사이에 약간의 차이는 있지만 비교적 잘 일치하였으며 채널의 단면 두께가 작기 때문에 제작상의 가공오차가 채널의 구조적인 안정성에 큰 영향을 미치는 것을 확인하였다.