Measurement and Analysis of Showcase Field Data

쇼케이스의 현장 데이터 측정 및 분석

  • Shin You-Hwan (Thermal/Flow Control Research Center, KIST) ;
  • Oh Wang-Kyu (Thermal/Flow Control Research Center, KIST) ;
  • Park Ki-Ho (Thermal/Flow Control Research Center, KIST) ;
  • Kim Youngil (Department of Energy System Engineering, Chungju University) ;
  • Shin Younggy (Mechanical Engineering Department, Sejong University)
  • 신유환 (한국과학기술연구원 열유동제어연구센터) ;
  • 오왕규 (한국과학기술연구원 열유동제어연구센터) ;
  • 박기호 (한국과학기술연구원 열유동제어연구센터) ;
  • 김영일 (충주대학교 에너지시스템공학과) ;
  • 신영기 (세종대학교 기계공학과)
  • Published : 2005.05.01

Abstract

Experimental study was performed to understand the operation of an on-site showcase working in a super discount store. Inlet and outlet temperatures of evaporator, condenser, expansion valve and compressor were measured for both air and refrigerant sides. Electric power consumption of compressors, defrosting heaters, cooling water pumps and etc. were measured. The operating characteristics of the showcase system under various working conditions were analyzed and discussed. During the defrosting process, the air temperature inside the showcase increased to $15^{\circ}C$, which gave harmful effect to the frozen food. The collected data will serve as valuable information for diagnosing and improving the performance of showcases.

Keywords

References

  1. Kwon, J.-T. and Kwon, Y.-C., 2003, Development trend of showcase equipment, Journal of SAREK, Vol. 32, No.7, pp.34-36
  2. Koo, N.-Y., Sung, D.-M. and Lee, Y-K, 2001, An experimental study for developing the defrost equipment of forced fan evaporator, Proceedings of the SAREK 2001 Winter Annual Conference, pp. 119-124
  3. Hayashi, Y, Aoki, K, Adachi, S. and Hori, K, 1977, Study of frost properties correlating with frost formation types, ASME Trans. J. of Heat Transfer, Vol. 99, No.2, pp. 239-245 https://doi.org/10.1115/1.3450675
  4. Frias, J. M. and Aceves, S. M., 1997, Effects of evaporator frosting on the performance of an air-to-air heat pump, Proceedings of the ASME Advanced Energy Systems Division, AES-Vol. 37, pp.357-363
  5. Chang, Y. H., 2002, Experimental study on the frost growth of fin-tube heat exchangers under frosting conditions, MS thesis, Korea University, Seoul, Korea
  6. Kondepudi, S. N. and O'Neal, D. L., 1990, The effect of different fin configurations on the performance of finned-tube heat exchangers under frosting conditions, ASHRAE Trans., Vol. 96, pp. 439-444
  7. Lee, K. S., Kim, J. M. and Jhee, S., 1999, A study of defrosting behavior according to surface characteristics in a fin-tube heat exchanger, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 11, No.6, pp. 921-927
  8. Aihara, T., Ohara, T., Shimoyama, T. and Kitano, H., 1997, Heat transfer and defrosting characteristics of a horizontal array of cooled tubes immersed in a very shallow fluidized bed, lnt. J. Heat and Mass Transfer, Vol. 40, No.8, pp. 1807-1815 https://doi.org/10.1016/S0017-9310(96)00258-X
  9. Cho, H., Kim, Y, Noh, H., Kim, Y and Park, Y C., 2002, Experimental study on the performance characteristics of hot-gas bypass and on-off defrosting cycle in a showcase refrigeration system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 14, No.6, pp.493-502