The comparison of cephalometric measurements between measuring methods in digital and conventional lateral cephalometric radiograph

디지털 및 일반 측방두부규격방사선사진에서 측정 방법에 따른 계측치의 비교

  • Kim Mi-Ja (Department of Oral and Maxillofacial Radiology, Dental Research institute, and BK21 College of Dentistry, Seoul National University) ;
  • Huh Kyung-Hoe (Department of Oral and Maxillofacial Radiology, Dental Research institute, and BK21 College of Dentistry, Seoul National University) ;
  • Yi Won-Jin (Department of Oral and Maxillofacial Radiology, Dental Research institute, and BK21 College of Dentistry, Seoul National University) ;
  • Heo Min-Suk (Department of Oral and Maxillofacial Radiology, Dental Research institute, and BK21 College of Dentistry, Seoul National University) ;
  • Lee Sam-Sun (Department of Oral and Maxillofacial Radiology, Dental Research institute, and BK21 College of Dentistry, Seoul National University) ;
  • Lee Jin-Koo (Department of Oral and Maxillofacial Radiology, Dental Research institute, and BK21 College of Dentistry, Seoul National University) ;
  • Ahn Byoung-Keun (Department of Dentistry, College of Medicine, Hallym University) ;
  • Choi Soon-Chul (Department of Oral and Maxillofacial Radiology, Dental Research institute, and BK21 College of Dentistry, Seoul National University)
  • 김미자 (서울대학교 치과대학 구강악안면방사선학교실, 치학연구소 및 BK2l) ;
  • 허경회 (서울대학교 치과대학 구강악안면방사선학교실, 치학연구소 및 BK2l) ;
  • 이원진 (서울대학교 치과대학 구강악안면방사선학교실, 치학연구소 및 BK2l) ;
  • 허민석 (서울대학교 치과대학 구강악안면방사선학교실, 치학연구소 및 BK2l) ;
  • 이삼선 (서울대학교 치과대학 구강악안면방사선학교실, 치학연구소 및 BK2l) ;
  • 이진구 (서울대학교 치과대학 구강악안면방사선학교실, 치학연구소 및 BK2l) ;
  • 안병근 (한림대학교 의과대학 치과학교실) ;
  • 최순철 (서울대학교 치과대학 구강악안면방사선학교실, 치학연구소 및 BK2l)
  • Published : 2005.03.01

Abstract

Purpose : To compare cephalometric measurement between measuring methods in digital and conventional lateral cephalometric radiograph. Materials and Methods : Twenty digital and conventional lateral cephalometric radiographs were selected. In digital group, cephalometric measurements were performed manually using hardcopies and automatically using $V-Ceph^{TM}$ program on the monitor. In conventional group, the same measurements were performed manually on conventional films, and for automatic measurement conventional films were digitized by scanner. All measurements were performed twice by 4 observers, and 24 cephalometric variables were calculated and the time spent for each measurement was recorded. The differences in measurements data and the time spent for each measurement were compared within each group. Intra-observer and inter-observer comparisons were performed. Results : In both groups, no statistically significant difference between manual and automatic measurements was observed and most of the variables didn't show statistically significant differences between methods. The observer with less experience tended to show statistically significant differences of measurements between methods, and differences from other observers. The differences of measurements between methods in digital group were lesser than those of conventional group with statistical significance in 8 variables out of 24. With automatic method and in digital group, the spent time was shorter. Conclusion : With direct digital radiograph, automatic method using manually idenitified landmarks can be preferable in cephalometric analysis. (Korean J Oral Maxillofac Radiol 2005; 35 : 15-23)

Keywords