The Experimental Study on Performance Improvement under frost conditions of the Heat Pump with Corrugate Shaped Fin and Two Compressors

저 착상 휜과 두 대 압축기 사이클을 이용한 히트펌프 난방성능 개선에 관한 연구

  • Hwang Yoon-Jei (Air Conditioner Group, Digital Appliance Research Laboratory) ;
  • Cho Eun-Jun (Air Conditioner Group, Digital Appliance Research Laboratory) ;
  • Chung Baik-Young (Air Conditioner Group, Digital Appliance Research Laboratory) ;
  • Lee Gam-gue (Air Conditioner Group, Digital Appliance Research Laboratory)
  • 황윤제 (LG전자 디지털 어플라이언스 연구소) ;
  • 조은준 (LG전자 디지털 어플라이언스 연구소) ;
  • 정백영 (LG전자 디지털 어플라이언스 연구소) ;
  • 이감규 (LG전자 디지털 어플라이언스 사업부)
  • Published : 2005.03.01

Abstract

This study presents the experimental study on improvement of frost/defrost performance in an heat pump system with newly developed fin and multiple compressors. As multiple compressors system, the variable and single speed compressor combinations has been introduced and compared with single speed 1-compressor system in a view point of improvement of frost/defrost performance. Also, newly developed corrugate shaped fin has been compared with conventional louver shaped fin. The frost/defrost performance is defined and some parameters are compared to discuss the effect of each combination. From this experimental study, it is known that if the variable and single speed compressor combination system equipped with corrugate shaped fin, the system performance has greatly improved not only for heating capacity, but also for frost performance.

Keywords

References

  1. Stoecker, W. F. 1957, How frost formation on coils affects refrigeration system, Refrigerating engineering, 43rd semiannual meeting of ASRE, pp.42-46
  2. Tassou, S. A., Marquand, C.J. and Wilson, D. R., 1983, Comparison of the performance of capacity controlled and conventional on/off controlled heat pumps, Applied Energy, Vol. 14, pp. 241-256 https://doi.org/10.1016/0306-2619(83)90051-X
  3. Ikemoto, Y., 1999, Economic/environmental aspect of modulation, refrigeration (in Japanese), Vol. 74, No. 863, pp.63-67
  4. Ryu, Y. H., Hwang, Y. J., Kim, C. M., Cho, K. S., 2002, Benchmark performance analysis of vapor compressor system with capacity modulation compressor, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 14, No. 2, pp. 98-107
  5. Kim, C. M., Hwang, Y. J., Chung, B. Y., 2003, The experimental study on uniform distribution of oil at the air conditioning system using two compressors, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 15, No. 2, pp. 103-108
  6. O'Neal, D. L., Kondepudi, S. N., 1989, Effect of frost growth on the performance of louvered finned tube heat exchangers, Int. J. of refrigeration, Vol. 12, No. 3, pp. 151-158 https://doi.org/10.1016/0140-7007(89)90030-3