CLINICAL AND RADIOLOGICAL COMPARISON BETWEEN TITANIUM AND BIODEGRADABLE MINIPLATE MONOCORTICAL OSTEOSYNTHESIS IN MANDIBULAR ANGLE FRACTURES

Monocortical Osteosynthesis 이론에 따른 하악골 우각부 골절 수술시 Titanium miniplate와 Biodegradable miniplate의 임상적, 방사선학적 비교 연구

  • Choi, Eun-Joo (Department of Oral & Maxillofacial Surgery, College of Dentistry, Yonsei University) ;
  • Nam, Woong (Department of Oral & Maxillofacial Surgery, College of Dentistry, Yonsei University) ;
  • Jung, Young-Soo (Department of Oral & Maxillofacial Surgery, College of Dentistry, Yonsei University) ;
  • Kim, Ki-Ho (Department of Oral & Maxillofacial Surgery, College of Dentistry, Yonsei University) ;
  • Kim, Hyung-Jun (Department of Oral & Maxillofacial Surgery, College of Dentistry, Yonsei University)
  • 최은주 (연세대학교 치과대학 구강악안면외과학교실) ;
  • 남웅 (연세대학교 치과대학 구강악안면외과학교실) ;
  • 정영수 (연세대학교 치과대학 구강악안면외과학교실) ;
  • 김기호 (연세대학교 치과대학 구강악안면외과학교실) ;
  • 김형준 (연세대학교 치과대학 구강악안면외과학교실)
  • Published : 2006.06.30

Abstract

The treatment objective of mandibular fracture is a return to normal function. According to Champy, a rigid fixation of mandibular angle fracture is performed by using 4 or 6 holes titanium miniplates on the external oblique ridge of mandible. However, the limitations of metal plate such as hypersensitivity, interference with the cranio-facial growth of growing child, secondary bone resorption around the plate, foreign body reaction, declination of primary callus formation, and bone atrophy due to the lack of normal stress reaction of the bone have been reported. Recently, biodegradable miniplate has been introduced and used as an alternative to the metal plate despite its lower strength than that of the titanium plate and the side effect caused by the resorption in the body. In this study, 61 patients diagnosed as mandibular angle fracture and treated from Jan. 1998 to Dec. 2004 in our department have been reviewed. Metal plate fixation was used in 50 patients and biodegradable plate fixation in 11 patients on the external oblique ridge around the fractured mandibular angle according to the principle of monocortical osteosynthesis by Champy. We compared the incidence of side effects and the degree of bony union at the mandibular inferior border in two different fixation methods. In conclusion, we have found that one miniplate regardless of matter could provide enough strength to grasp bony fragments of the tension site and compress the inferior border of mandible without any complications.

Keywords

References

  1. Champy M, Pape HD, Gerlach KL, Lodde JP: The Strasbourg miniplate osteosynthesis. In Kruger E, Schilli W: Oral and maxillofacial traumatology Vol. 2. Quintessence Publishing, Chicago, 1986, p 19-43
  2. Michelet FX, Deymes J, Dessus B: Osteosynthesis with miniaturized screwed plates in maxillofacial surgery. J Maxillofac Surg 1973;1:79-84 https://doi.org/10.1016/S0301-0503(73)80017-7
  3. Champy M, Lodde JP, Schmitt R, et al.: Mandibular osteosynthesis by miniaturized screw plate via a buccal approach. J Maxillofac Surg 1978;6:14-21 https://doi.org/10.1016/S0301-0503(78)80062-9
  4. Champy M, Lodde JP, Schmitt R, et al.: Mandibular osteosynthesis by miniaturized screw plate via a buccal approach. J Maxillofac Surg 1978;6:14-21 https://doi.org/10.1016/S0301-0503(78)80062-9
  5. Suuronen R, Pohjonen T, Vasenius J, Vainiopnpaa S: Comparison of absorbable self-reinforced multilayer poly-1-Lactide and metallic plates for the fixation of mandibular body osteotomies. J Oral Maxillofac Surg 1992;50:255-262 https://doi.org/10.1016/0278-2391(92)90322-Q
  6. Kim YK, Yeo HH, Lim SC: Tissue response to titanium plates: A transmitted electron microscopic study. J Oral Maxillofac Surg 1997;55:322-326 https://doi.org/10.1016/S0278-2391(97)90115-4
  7. Jan T, Jan-Paul VL, Bert O, Rudolf R.M. Bos: A Computer study of biodegradable plates for internal fixation of mandibular angle fractures. J Oral Maxillofac Surg 2001;59:404-407 https://doi.org/10.1053/joms.2001.21877
  8. Kim YK, Kim SG: Treatment of Mandible Fractures Using Bioabsorbable Plates : Preliminary Study. 대한구강악안면외과학회지 2001;27:570-575
  9. Steiner M, Von Fraunhofer JA, Mascaro J: The possible role of corrosion in inhibiting the healing of a mandibular fracture : report of a case. J Oral Surg 1981;39:140
  10. Wright JK, Axon HJ: Electrolysis and stainless steel in bone. J Bone Joint Surg 1956;38B:745
  11. Bago-Granell J et al: Malignant fibrous histiocytoma of bone at the site of a total hip arthroplasty. J Bone Joint Surg 1984;66B:38
  12. Messer EJ, Hayes DC, Bitbe?PJ: Use of intraosseous metal appliances in fixation of mandibular fractures. J Oral Surg 1967;25:493
  13. Bouwman JP, Tuinzing DB, Kostense PJ: A Comparative in vitro study on fixation of sagittal split osteotoies with Wurzburg screws, Champy miniplates, and Biofix (biodegradable) rods. Int J Oral Maxillofac Surg 1994;23:46 https://doi.org/10.1016/S0901-5027(05)80327-3