Risk Assessment by Toluene Source Emission Model in Indoor Environments of New Houses

신축 주택의 톨루엔 발생량 모델을 이용한 건강위해성 평가

  • Kim, Young-Hee (Department of Occupational Health, Catholic University of Daegu) ;
  • Yang, Won-Ho (Department of Occupational Health, Catholic University of Daegu) ;
  • Son, Bu-Soon (Department of Environmental Health Science, Soonchunhyang University)
  • 김영희 (대구가톨릭대학교 산업보건학과) ;
  • 양원호 (대구가톨릭대학교 산업보건학과) ;
  • 손부순 (순천향대학교 환경보건학과)
  • Published : 2006.10.31

Abstract

Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Understanding the effectiveness of indoor air quality control depends on knowledge of the characteristics of air pollutants in indoor air, especially their quantities and persistence, and the relevance of indoor sources to these factors. Toluene within new and established houses has been determined and factors significant to its presence have been identified. A total of 30 selected houses in Seoul, Asan and Daegu areas that were constructed within 4 years and over 4 years of construction were measured the concentration of toluene from July to September in 2004. Toluene emission decay of double-exponential model exhibited good fit of $Y=276.37e^{-1.21x}(R^{2}=0.34,\;P=0.06)$ for 2 years and then $Y=51.54e^{-0.11x}(R^{2}=0.40,\;P=0.0)$ from 23 years in new houses. In case of living in new houses, noncarcinogenic health effects of exposure to toluene was 1.38 of hazard quotient (HQ) comparing to toluene reference dose of 0.13 mg/kg-day.

Keywords

References

  1. 이철민, 김윤신, 이태형, 김종렬, 김중호 : 확률론적 모의실험을 이용한 공기청정기의 실내공기중 PM10과 NO2 제거 효율에 관한 연구. 한국환경보건학회지, 30(3), 221-229, 2004
  2. Jones, A. P. : Indoor air quality and health. Atmospheric Environment, 33, 4535-4564, 1999 https://doi.org/10.1016/S1352-2310(99)00272-1
  3. 환경부 : 실내공간 공기오염특성 및 관리방안, 2001
  4. Henry, C. J., Fishbein, L., Meggs, W. J., Ashford, N. A., Schul te, P. A., Anderson, H., Osborne, J. S . and Sepkovic, D. W. : Approaches for assessing health risks from compl ex m ixtures in i ndoor air: A p anel overview. Environmental Health Perspectives, 95, 135-143, 1991 https://doi.org/10.2307/3431120
  5. 김남진, 이지영, 이호찬, 서광석, 이석보, 전재식, 김민영 : 공동주택의 새집증후군 유발물질 실태조사. 한국대기환경학회 2006 춘계학술대회 논문집, 183-184, 2006
  6. Ott, W., Switzer, P. and Robinson, J. : Particle concentrations inside a tavern before and after prohibition of smoking: evaluating the performance of an indoor air quality model. Journal of the Air & Waste Management Association, 46, 1120-1134, 1994
  7. Nazaroff, W. W. and Cass, G. R. : Mathematical modeling of chemically reactive pollutants in indoor air. Environmental Science and Technology, 20, 924-934, 1986 https://doi.org/10.1021/es00151a012
  8. 양원호, 배현주, 이기영, 정문호 : 측정시간에 따른 거주지역 환기량 계산 오류에 관한 연구. 한국환경위생학회지, 26(3), 50-54, 2000
  9. Yang, W., Lee, K. and Chung, M. : Characterization of indoor air quality using multiple measurements of nitrogen dioxide. Indoor Air, 14, 105-111, 2004 https://doi.org/10.1046/j.1600-0668.2003.00216.x
  10. Ellacott, M. V. and Reed, S. : Development of robust indoor air quality models for the estimation of volatile organic compound concentrations in buildings. Indoor Built Environment, 8, 345-360, 1999
  11. Brown, S. K. : Volatile organic pollutants in new and established buildings in Melbourne, Australia. Indoor Air, 12, 55-63, 2002 https://doi.org/10.1034/j.1600-0668.2002.120107.x
  12. Hoddinott, K. B. and Lee, A. P. : The use of environmental risk assessment methodologies for an indoor air quality investigation. Chemosphere, 41, 77-84, 2000 https://doi.org/10.1016/S0045-6535(99)00392-6
  13. Naugl e, E . F. and P l erson, T . K. : A f ramework for risk characterization of environmental pollutants. Journal of the Air & Waste Management Association, 41(10), 1298-1307, 1991 https://doi.org/10.1080/10473289.1991.10466923
  14. US EPA : http:\\www.epa.gov\IRIS