Study on Thermal Comfort and Indoor Air Quality in the Classroom with System Air-conditioner and Ventilation System for Cooling Loads

시스템에어컨과 환기시스템 설치 강의실에서 냉방시 열쾌적성 및 실내공기질 연구

  • 노광철 (서울시립대학교 대학원 기계정보공학과) ;
  • 장재수 (LG전자 DAC연구소) ;
  • 오명도 (서울시립대학교 기계정보공학과)
  • Published : 2006.01.01

Abstract

The experimental and the numerical study was performed on the comparison of thermal comfort(TC) and indoor air quality(IAQ) in the lecture room for cooling loads when the operating conditions are changed. PMV value and $CO_2$ concentration of the lecture room were measured and compared with the numerical results. The numerical results showed a good agreement with the experimental one and then the numerical tool was used to analyze thermal comfort and IAQ for a couple of operating conditions. As a result it was found that the increment of the discharge angle of system air-conditioner makes TC uniformity worse, but rarely affects IAQ. Also TC and IAQ were hardly affected by the variation of the discharge airflow. Finally it turned out that TC is merely affected by the increment of the ventilation airflow, but the average $CO_2$ concentration can be satisfied with Japanese IAQ standards of classrooms when the ventilation airflow is more than $800m^3/h$ in this study.

Keywords

References

  1. Minister of Environment of Korea, 2002, 'A Study on Indoor Air Pollution Characterization and Management,' Minister of Environment of Korea
  2. Kim, Y. C. and Oh, M. D., 2004, 'Establishing a Standard for Multi-Split Air-Conditioners and Overview on ISO Draft,' Proceedings of the SAREK 2004 Summer Annual Conference, pp. 1004-1007
  3. Choi, J. M., Kim, Y. i. and Park, H. S., 2003, 'A Study on the Evaluation of Heating-Conditioned Environment with the Size of Classroom,' Journal of SAREK, Vol. 15, No. 12, pp. 1035-1042
  4. Cho, Y. J., 2001, 'ADPI Characteristics of Diffuser in a Room with Perirnetric Heating Load,' Ph.D. Dissertation, Hanyang University
  5. Kim, S, H., Noh, K. C. and Oh, M. D., 2003, 'Evaluation of Thermal Comfort in Consideration of the Solar Radiation,' Journal of SAREK, Vol. 16, No. 12, pp. 1140-1148
  6. Wong, N. H. and Khoo, S. S., 2003, 'Thermal Comfort in Classrooms in the Tropics,' Energy and Buildings, Vol. 35, pp. 337-351 https://doi.org/10.1016/S0378-7788(02)00109-3
  7. Kim, T. Y., 2004, 'Analysis of Contribution Ratio of Pollutant Sources to Indoor Air Quality,' Journal of Architectural Institute of Korea, Vol. 20, No. 2, pp. 209-216
  8. Ahn, C. L., Kim, J. J, Kum, J. S. and Park, H. S., 'A Study on the Using the Ventilation System as the Method of Improvement of Air Quality in the Schools,' Journal of Korean Institute of Education Facilities, Vol. 11, No. 2, pp. 17-23
  9. Lee, S. C. and Chang, M., 1999, 'Indoor Air Quality Investigations at Five Classrooms,' Indoor air, Vol. 9, pp. 134-138 https://doi.org/10.1111/j.1600-0668.1999.t01-2-00008.x
  10. Fang, L., Wyon, D. P., Clausen, G. and Fanger, P. O., 2004, 'Impact of Indoor Air Temperature and Humidity in an Office on Perceived Air Quality, SBS Symptoms and Performance,' Indoor Air, Vol. 14, pp. 74-81 https://doi.org/10.1111/j.1600-0668.2004.00276.x
  11. Kim, K. H., Lee, K. S., Choi, H. S., Kang, T. W., Chung, B. Y. and Lee, G. G, 2003, 'A Study on the Indoor Thermal and Ventilation Characteristics in Office Building with Air-Conditioning and Ventilation System,' Preceedings of the SAREK 2003 Summer Annual Conference, pp. 1111-1116
  12. Kim, K. H., Choi, H. S., Lee, G. G., Han, H. T. and Kwon, Y. I., 2004, 'The Characteristics of an Indoor Air Environment in Office with Location of Supply and Exhaust Diffuser,' Proceedings of the SAREK 2004 Summer Annual Conference, pp. 734-738
  13. ASHRAE, 2004, Thermal Environmental Conditions for Human Occupancy, ANSI/ASHRAE Standard 55-2004, ASHRAE, Atlanta, Georgia
  14. Minister of Environment of Korea, 2003, 'The Act of Indoor Air Qualities for Multiple-Use Facilities,' Minister of Law of Korea
  15. Patankar, S. V., 1980, Numerical Heat Transfer and Fluid Flow, Hemisphere, Washington, DC
  16. ASHRAE, 2001, Ventilation for Acceptable Indoor Air Quality, ANSI/ASHRAE Standard 62-2001, ASHRAE, Atlanta, Georgia