Flow Measurement in the Hemodialysis Vascular Conduit for Surveillance of Internal Arteriovenous Fistula: A Trend Analysis

혈액 투석을 위한 내동정맥루 감시를 위한 투석관 내 혈류량 측정: 경향 분석

Lee, Jong-Hoon;Yoon, Soo\-Young;Cho, Hyeon-Kyeong;Song, Soon-Young;Yang, Sung-Ja;Ahn, Hyung-Joon;Cho, Hee-Eun;Kim, Yu-Seun;Park, Ki-Il
이종훈;윤수영;조현경;송순영;양성자;안형준;조희은;김유선;박기일

  • Published : 20060000

Abstract

Purpose: We have already reported on a new method to calculate the intra-vascular conduit flow rate based on Bernoulli's theory for maintaining surveillance of the arteriovenous fistula (AVF) function. To assess the clinical validity of our methods, we examined a trend analysis on the calculated flow rate in hemodialysis vascular conduits. Methods: From a total of 27 cases of native AVFs that were at least 3 months after construction, we measured the AVF flow rate (QD) with Doppler ultrasonography first. When QD was below 600 ml/min, a fistulogram was taken. The intra- vascular conduit static pressure (ps) was measured, and the flow rate (Qa) was calculated every month with using the mean arterial pressure. The patients with a decreased Qa of more than 10% over 3 months were referred for a diagnostic fistulogram. Results: Twenty-seven AVFs were studied after 29.5⁑28.5 (4∼120) months of operation. The mean QD was 980.6⁑501.6 (144∼2,230) ml/min. In 6 patients who showed a QD less than 600 ml/min, 4 pathologic lesions were found on the diagnostic fistulogram: juxta-anastomosis stenosis (n=3) and a draining venous stenosis (n=1). Three patients who showed a Qa decrement were confirmed as having a draining venous stenosis. However, any unpredictable thrombosis with proximal stenosis (n=2) couldn't be detected. Conclusion: Qa represents the narrowing of the draining vein of an internal AVF. However, arterial or venous narrowing that is proximal to the arterial puncture site couldn't be detected with the calculated intra-conduit flow rate. The development of new methods that can detect proximal vascular stenosis and that can be used in combination with our method is anticipated in the near future. (J Korean Surg Soc 2006;71:139-144)

Keywords

References

  1. National Kidney Foundation. K/DOQI clinical practice guidelines for vascular access, 2000. Am J Kidney Dis 2001;37:S137-81 https://doi.org/10.1016/S0272-6386(01)70007-8
  2. Schwarz C, Mitterbauer C, Boczula M, Maca T, Funovics M, Heinze G, et al. Flow monitoring: performance characteristics of ultrasound dilution versus Doppler ultrasound compared with fistulography. Am J Kidney Dis 2003;42:539-45 https://doi.org/10.1016/S0272-6386(03)00786-8
  3. Hakim R, Himmelfarb J. Hemodialysis access failure: a call to action. Kidney Int 1998;54:1029-40 https://doi.org/10.1046/j.1523-1755.1998.00122.x
  4. Schwab SJ, Raymond JR, Saeed M, Newman GE, Dennis PA, Bollinger RR. Prevention of hemodialysis fistula thrombosis. Early detection of venous stenosis. Kidney Int 1989;36:707-11 https://doi.org/10.1038/ki.1989.250
  5. Besarab A, Sullivan KL, Ross RP, Moritz MJ. Utility of intraaccess pressure monitoring in detecting and correcting venous outlet stenoses prior to thrombosis. Kidney Int 1995;47:1364-73 https://doi.org/10.1038/ki.1995.192
  6. Sands JJ, Miranda CL. Prolongation of hemodialysis access survival with elective revision. Clin Nephrol 1995;44:329-33
  7. Either J, Falardeau P, Vandeville B, Roy L, legault L, Gascon M, et al. Access flow monitoring of native fistula using ultrasound dilution technique: 30 months experience. J Am Soc Nephrol 2000;11:A183
  8. Safa AA, Valji K, Roberts AC, Ziegler TW, Hye RJ, Ogleivie SB. Detection and treatment of dysfunctional hemodialysis access graft: effect of surveillance program on graft patency and the incidence of thrombosis. Radiology 1996;199:653-7 https://doi.org/10.1148/radiology.199.3.8637982
  9. McCarley P, Wingard RL, Shyr Y, Pettus W, Hakim RM, Ikizler TA. Vascular access blood flow monitoring reduces access morbidity and costs. Kidney Int 2001;60:1164-72 https://doi.org/10.1046/j.1523-1755.2001.0600031164.x
  10. Krivitski NM, Gantela S. Access flow measurement as a predictor of hemodialysis graft thrombosis: making clinical decisions. Semin Dial 2001;14:181-5 https://doi.org/10.1046/j.1525-139X.2001.00050.x
  11. Paulson WD. Blood flow surveillance of hemodialysis grafts and the dysfunction hypothesis. Semin Dial 2001;14:175-60 https://doi.org/10.1046/j.1525-139X.2001.00049.x
  12. Krivitski NM. Theory and validation of access flow measurement by dilution technique during hemodialysis. Kidney Int 1995;48:244-50 https://doi.org/10.1038/ki.1995.290
  13. Frinak S, Zasuwa G, Dunfee T, Besarab A, Yee J. Dynamic venous access pressure ratio test for hemodialysis access monitoring. Am J Kidney Dis 2002;40:760-7 https://doi.org/10.1053/ajkd.2002.35687
  14. Strauch BS, O'Connell RS, Geoly KL, Grundlehner M, Yakub YN, Tietjen DP. Forecasting thrombosis of vascular access with doppler color flow imaging. Am J Kidney Dis 1992;19:554-7 https://doi.org/10.1016/S0272-6386(12)80834-1
  15. Finlay DE, Longley DG, Foshager MC, Letourneau JG. Duplex and color Doppler sonography of hemodialysis arteriovenous fistulas and grafts. Radiographics 1993;13:983-9 https://doi.org/10.1148/radiographics.13.5.8210602
  16. Bay WH, Henry ML, Lazarus JM, Lew NL, Ling J, Lowrie EG. Predicting hemodialysis access failure with color flow Doppler ultrasound. Am J Nephrol 1998;18:296-304 https://doi.org/10.1159/000013354
  17. Oates CP, Williams ED, Mchugh MI. The use of diasonics DRF400 duplex ultrasound scanner to measure volume flow in arteriovenous/fistulae in patients undergoing hemodialysis: an analysis of measurement uncertainties. Ultrasound Med Biol 1990;16:571-9 https://doi.org/10.1016/0301-5629(90)90022-5
  18. Lee JH, Song SY, Cho HK, Yoon SY, Yang SJ, Huh KH, et al. Development of simple flow measurement in the vascular access conduit based on the Bernoulli's theory. J Korean Vasc Surg Soc 2004;20:115-24
  19. Lee JH, Huh KH, Kim YS, Cho HE, Park K. Flow measurement in vascular access conduit: an ex vivo experimental model. J Korean Surg Soc 2005;68:253-7
  20. Hoeben H, Abu-Alfa AK, Reilly RF, Aruny JE, Bouman K, Perazella MA. Vascular access surveillance: evaluation of combining dynamic venous pressure and vascular access blood flow measurements. Am J Nephrol 2003;23:403-8 https://doi.org/10.1159/000074297
  21. Cayco AV, Abu-Alfa AK, Mahnensmith RL, Perazella MA. Reduction in arteriovenous graft impairment: results of a vascular access surveillance protocol. Am J Kidney Dis 1998;32:302-8 https://doi.org/10.1053/ajkd.1998.v32.pm9708617
  22. Kleinekofort W, Kraemer M, Rode C, Wizemann V. Extracorporeal pressure monitoring and the detection of vascular access stenosis. Int J Artif Organs 2002;25:45-50
  23. Besarab A, Moritz M, Sullivan K, Dorrell S, Price JJ. Venous access pressures and the detection of intra-access stenosis. ASAIO J 1992;38:M519-23 https://doi.org/10.1097/00002480-199207000-00089
  24. Besarab A, Frinak S, Sherman RA, Goldman J, Dumler F, Devita MV, et al. Simplified measurement of intra-access pressure. J Am Soc Nephrol 1998;9:284-9
  25. Spergel LM, Holland JE, Fadem SZ, McAllister CJ, Peacock EJ. Static intra-access pressure ratio does not correlate with access blood flow. Kidney Int 2004;66:1512-6 https://doi.org/10.1111/j.1523-1755.2004.00946.x
  26. Work J. Does vascular access monitoring work- Adv Ren Replace Ther 2002;9:85-90 https://doi.org/10.1053/jarr.2002.33520
  27. Garland JS, Moist LM, Lindsay RM. Are hemodialysis access flow measurements by ultrasound dilution the standard of care for access surveillance- Adv Ren Replace Ther 2002;9:91-8 https://doi.org/10.1053/jarr.2002.33523
  28. Shahin H, Reddy G, Sharafuddin M, Katz D, Franzwa BS, Dixon BS. Monthly access flow monitoring with increased prophylactic angioplasty did not improve fistula patency. Kidney Int 2005;68:2352-61 https://doi.org/10.1111/j.1523-1755.2005.00697.x