References
- National Kidney Foundation. K/DOQI clinical practice guidelines for vascular access, 2000. Am J Kidney Dis 2001;37:S137-81 https://doi.org/10.1016/S0272-6386(01)70007-8
- Schwarz C, Mitterbauer C, Boczula M, Maca T, Funovics M, Heinze G, et al. Flow monitoring: performance characteristics of ultrasound dilution versus Doppler ultrasound compared with fistulography. Am J Kidney Dis 2003;42:539-45 https://doi.org/10.1016/S0272-6386(03)00786-8
- Hakim R, Himmelfarb J. Hemodialysis access failure: a call to action. Kidney Int 1998;54:1029-40 https://doi.org/10.1046/j.1523-1755.1998.00122.x
- Schwab SJ, Raymond JR, Saeed M, Newman GE, Dennis PA, Bollinger RR. Prevention of hemodialysis fistula thrombosis. Early detection of venous stenosis. Kidney Int 1989;36:707-11 https://doi.org/10.1038/ki.1989.250
- Besarab A, Sullivan KL, Ross RP, Moritz MJ. Utility of intraaccess pressure monitoring in detecting and correcting venous outlet stenoses prior to thrombosis. Kidney Int 1995;47:1364-73 https://doi.org/10.1038/ki.1995.192
- Sands JJ, Miranda CL. Prolongation of hemodialysis access survival with elective revision. Clin Nephrol 1995;44:329-33
- Either J, Falardeau P, Vandeville B, Roy L, legault L, Gascon M, et al. Access flow monitoring of native fistula using ultrasound dilution technique: 30 months experience. J Am Soc Nephrol 2000;11:A183
- Safa AA, Valji K, Roberts AC, Ziegler TW, Hye RJ, Ogleivie SB. Detection and treatment of dysfunctional hemodialysis access graft: effect of surveillance program on graft patency and the incidence of thrombosis. Radiology 1996;199:653-7 https://doi.org/10.1148/radiology.199.3.8637982
- McCarley P, Wingard RL, Shyr Y, Pettus W, Hakim RM, Ikizler TA. Vascular access blood flow monitoring reduces access morbidity and costs. Kidney Int 2001;60:1164-72 https://doi.org/10.1046/j.1523-1755.2001.0600031164.x
- Krivitski NM, Gantela S. Access flow measurement as a predictor of hemodialysis graft thrombosis: making clinical decisions. Semin Dial 2001;14:181-5 https://doi.org/10.1046/j.1525-139X.2001.00050.x
- Paulson WD. Blood flow surveillance of hemodialysis grafts and the dysfunction hypothesis. Semin Dial 2001;14:175-60 https://doi.org/10.1046/j.1525-139X.2001.00049.x
- Krivitski NM. Theory and validation of access flow measurement by dilution technique during hemodialysis. Kidney Int 1995;48:244-50 https://doi.org/10.1038/ki.1995.290
- Frinak S, Zasuwa G, Dunfee T, Besarab A, Yee J. Dynamic venous access pressure ratio test for hemodialysis access monitoring. Am J Kidney Dis 2002;40:760-7 https://doi.org/10.1053/ajkd.2002.35687
- Strauch BS, O'Connell RS, Geoly KL, Grundlehner M, Yakub YN, Tietjen DP. Forecasting thrombosis of vascular access with doppler color flow imaging. Am J Kidney Dis 1992;19:554-7 https://doi.org/10.1016/S0272-6386(12)80834-1
- Finlay DE, Longley DG, Foshager MC, Letourneau JG. Duplex and color Doppler sonography of hemodialysis arteriovenous fistulas and grafts. Radiographics 1993;13:983-9 https://doi.org/10.1148/radiographics.13.5.8210602
- Bay WH, Henry ML, Lazarus JM, Lew NL, Ling J, Lowrie EG. Predicting hemodialysis access failure with color flow Doppler ultrasound. Am J Nephrol 1998;18:296-304 https://doi.org/10.1159/000013354
- Oates CP, Williams ED, Mchugh MI. The use of diasonics DRF400 duplex ultrasound scanner to measure volume flow in arteriovenous/fistulae in patients undergoing hemodialysis: an analysis of measurement uncertainties. Ultrasound Med Biol 1990;16:571-9 https://doi.org/10.1016/0301-5629(90)90022-5
- Lee JH, Song SY, Cho HK, Yoon SY, Yang SJ, Huh KH, et al. Development of simple flow measurement in the vascular access conduit based on the Bernoulli's theory. J Korean Vasc Surg Soc 2004;20:115-24
- Lee JH, Huh KH, Kim YS, Cho HE, Park K. Flow measurement in vascular access conduit: an ex vivo experimental model. J Korean Surg Soc 2005;68:253-7
- Hoeben H, Abu-Alfa AK, Reilly RF, Aruny JE, Bouman K, Perazella MA. Vascular access surveillance: evaluation of combining dynamic venous pressure and vascular access blood flow measurements. Am J Nephrol 2003;23:403-8 https://doi.org/10.1159/000074297
- Cayco AV, Abu-Alfa AK, Mahnensmith RL, Perazella MA. Reduction in arteriovenous graft impairment: results of a vascular access surveillance protocol. Am J Kidney Dis 1998;32:302-8 https://doi.org/10.1053/ajkd.1998.v32.pm9708617
- Kleinekofort W, Kraemer M, Rode C, Wizemann V. Extracorporeal pressure monitoring and the detection of vascular access stenosis. Int J Artif Organs 2002;25:45-50
- Besarab A, Moritz M, Sullivan K, Dorrell S, Price JJ. Venous access pressures and the detection of intra-access stenosis. ASAIO J 1992;38:M519-23 https://doi.org/10.1097/00002480-199207000-00089
- Besarab A, Frinak S, Sherman RA, Goldman J, Dumler F, Devita MV, et al. Simplified measurement of intra-access pressure. J Am Soc Nephrol 1998;9:284-9
- Spergel LM, Holland JE, Fadem SZ, McAllister CJ, Peacock EJ. Static intra-access pressure ratio does not correlate with access blood flow. Kidney Int 2004;66:1512-6 https://doi.org/10.1111/j.1523-1755.2004.00946.x
- Work J. Does vascular access monitoring work- Adv Ren Replace Ther 2002;9:85-90 https://doi.org/10.1053/jarr.2002.33520
- Garland JS, Moist LM, Lindsay RM. Are hemodialysis access flow measurements by ultrasound dilution the standard of care for access surveillance- Adv Ren Replace Ther 2002;9:91-8 https://doi.org/10.1053/jarr.2002.33523
- Shahin H, Reddy G, Sharafuddin M, Katz D, Franzwa BS, Dixon BS. Monthly access flow monitoring with increased prophylactic angioplasty did not improve fistula patency. Kidney Int 2005;68:2352-61 https://doi.org/10.1111/j.1523-1755.2005.00697.x