An Experimental Study of Spalling Characteristics of High-Strength Reinforced Concrete Columns with PP Fibers

PP 섬유를 함유한 고강도 철근콘크리트 기둥의 폭열 특성에 관한 실험적 연구

  • 신성우 (한양대학교 건축학부) ;
  • 유석형 (한양대학교 친환경건축 기술혁신 연구센터)
  • Received : 2005.08.11
  • Published : 2006.03.30

Abstract

A spalling is defined as the damages of concrete exposed to high temperature during the fire by causing cracks and localized bursting of small pieces of concrete. It is reported that spalling is caused by the vapor pressure and polypropylene(PP) fiber has an important role in protecting from spalling. The characteristics of fire resistance of high-strength reinforced concrete columns with various concrete strength and various contents of PP fiber were investigated in this study. In results, the ratio of unstressed residual strength of columns increases as the concrete strength increases and the ratio of unstressed residual strength of columns exposed to fire decreases as the content of PP fiber increases from 0% to 0.2%.

고강도 콘크리트는 구조적인 장점에도 불구하고 화재 시 폭렬과 함께 취성적인 파괴를 나타내는 단점으로 인하여 내화설계 시 주의하여 사용하여야 한다. 고강도 콘크리트의 폭렬제어를 위하여 폴리프로필렌 섬유(PP섬유)의 혼입이 가장 효율적인 것으로 여러 연구결과를 통하여 보고 되었으나, 이들은 대부분 콘크리트 공시체를 대상으로 한 내화실험의 결과로서 최적의 PP섬유 혼입량에 대한 부재수준의 연구는 매우 부족한 실정이다. 본 연구에서는 고강도 콘크리트 기둥의 내화설계를 위한 최적의 PP섬유 혼입량을 제시하기 위하여 콘크리트 강도와 PP섬유의 혼입량을 변수로 하는 기둥부재의 내화실험 및 잔존강도 실험을 수행하였으며, 실험결과 콘크리트 강도가 증가 할수록 기둥 실험체의 잔존 축강도비는 증가하였으며, PP섬유 혼입량을 0%에서 0.2%까지 증가 시킬수록 기둥의 잔존 축강도비가 증가하는 것으로 나타났다. 따라서 최적의 PP섬유 혼입량으로서 0.2%가 적절할 것으로 판단된다.

Keywords

References

  1. 한천구, 양성환, 이병열, 황인성, "골재종규 및 폴리프로필렌 섬유 혼입률 변화에 따른 고성능 콘크리트의 폭렬특성에 관한 연구", 콘크리트학회논문집, 통권53호 제11권 5호, 1999, pp.69-78.
  2. 한천구, 양성환, 이병열, 황인성, "혼화재 종류 및 폴리프로필렌 섬유의 혼입률 변화에 따른 고성능 콘크리트의 폭렬 특성", 구조물진단학회지, 통권11호 제 4권 제1호, 2000, pp.85-92.
  3. 한천구, 양성환, 이병열, 황인성, "W/C 및 폴리프로필렌 섬유의 혼입률 변화에 따른 콘크리트 고온시 성상", 대한건축학회 구조계 논문집, 제16권 10호, 2000. 10, pp. 81-88
  4. 권영진, 장재봉, 나철성, 김무한, "고성능 콘크리트의 폭렬현상과 대책에 관한 연구동향", 콘크리트학회지 특집기사, 통권86호 제17권 3호, 2005.
  5. L. Sarvaranta, E. Mikkola, Fiber mortar composites in fire conditions, Fire Mater 18, 1994, pp. 45-50. https://doi.org/10.1002/fam.810180106
  6. L. Sarvaranta, E. Mikkola, Fiber mortar composites under fire conditions: Effects of ageing and moisture content of specimens, Mater Struct. 27, 1994, pp. 532-538. https://doi.org/10.1007/BF02473214
  7. Pierre Kalifa, "High-Temperature behaviour of HPC with polypropylene fibers from spalling to microstructures", Cement and Concrete Research, Jun., 2001, pp.1487-1499.
  8. U. Diederichs, U.M. Jumppanen, U. Schneider, High temperature properties and spalling behaviour of high strength concrete, 4th Int. Workshop on High Performance Concrete Characteristics, Material Properties and Structural Performance, Weimar, Germany, October 5-6, 1995.
  9. T. Lennon, N. Clayton, Fire tests on high grade concrete with polypropylene fibres, BRE Report 395, 1995.
  10. D. Bentz, "Fibers, percolation and spalling of high performance concrete", ACI material Journal, March, 2000, pp.351-359.
  11. Zdenek P. Bazant, Maurice F. Kaplan, "Concrete at High Temperatures : Material Properties and Mathematical Models", Prentice Hall, 1996.
  12. NIST, "International Workshop on Fire Performance of High-Strength Concrete", Md Gaithersburg, Feb., 1997.
  13. NISTIR 5934, "Fire Performance of High-Strength Concrete : A Report of the State-of-the-Art", NIST, Dec., 1996.
  14. L. Sarvaranta, E. Jarvela, E. Mikkola, Fiber mortar composites under thermal ezposure, in: Pluralis(Ed.), Proceedings of 2nd International Symposium on Textile Composites in Building Construction, Lyon, France, 23-25 June 1992, pp. 47-56.
  15. Sullivan, P.J.E., and Sharshar, R., "Performance of concrete at elevated temperatures(as measured by the reduction in compressive strength", Fire Technology, V. 28, No. 3, August, 1992, pp.240-250. https://doi.org/10.1007/BF01857693