A Development of Coupled Simulation Tool to Evaluate Performance of Ventilation System

환기시스템의 성능평가를 위한 통합 시뮬레이션 Tool의 개발

  • Cho Wang-Hee (Graduate School, Sungkyunkwan University) ;
  • Song Doo-Sam (Depoartment of Architectural engineering, Sungkyunkwan University)
  • Published : 2006.02.01

Abstract

To evaluate the performance of ventilation system properly, the correlations among the ventilation rate, indoor air-quality and cooling/heating load should be analysed. In this study, simulation tool to analyze the performance of ventilation system was developed. The simulation tool is based on the TRNSYS and some modules to calculate concentration of pollutants with the operation of ventilation system and to decide the signal of ventilation system were newly developed in this study. And these modules coupled with building load and heating/cooling simulation modules. To verify the validity of developed simulation tool, comparison study between simulation and field study were accomplished. As results, the simulation tool developed in this study can be used to predict the performance of ventilation system with accuracy.

Keywords

References

  1. Kong, S. H., 2000, The Magazine of the Society of Air-Conditioning and Refrigerating Engineers, Vol. 29, No. 4, pp. 56-59
  2. Yoon, J. H., 2002, The Magazine of the Society of Air-Conditioning and Refrigerating Engineers, Vol. 31, No. 4, pp. 7-11
  3. Kim, W. J., 2004, The Magazine of the Society of Air-Conditioning and Refrigerating Engineers, Vol. 33, No. 1, pp. 22-27
  4. Lee, Y. K., 2004, The Magazine of the Society of Air-Conditioning and Refrigerating Engineers, Vol. 33, No. 6, pp. 24-31
  5. Architectural Institute of Japan, 2002, Plan Bible regard in Sick House Syndrome, Changkuksa, pp. 122-123
  6. Andrew, K. P. and Elizabeth, M. I., 2001, Input data for multizone airflow and IAQ analysis, National Institute of Standards and Technology
  7. Ko, H. J., Song, D. S. and Cho, W. H., 2005, The Effects of Ventilation System on IAQ in an Apartment House, Proceedings of the SAREK 2005 Summer Annual Conference, pp. 848-854
  8. Kim, J. Y., Kim, E. S., Kim, T. Y. and Leigh, S. B., 2005, A prediction of IAQ based on distribution of indoor pollutant concentration, Proceedings of the SAREK 2005 Summer Annual Conference, pp. 97-102
  9. ASHRAE Standard 62-99, 1999, Ventilation for Acceptable Indoor Air Quality
  10. TRNSYS reference manual, 2000, Solar Energy Laboratory, University of Wisconsin-Madison
  11. Cho, W. H., 2003, A Study on the Proposal of Ventilation System for Improving IAQ and Development of Simulation Tool to Evaluate its Performance, Sungkyunkwan University, Suwon, Korea