Fuzzy Control Algorithms for the Compressor and the Electronic Expansion Valve of a Multi-type Air-conditioning System using Multiple Input Variables

다입력변수를 사용한 멀티형 공조시스템 압축기와 전자팽창밸브의 퍼지 제어 알고리즘

  • Han, Do-Young (School of Mechanical and Automotive Engineering, Kookmin University) ;
  • Park, Kwan-Jun (Graduate School of Mechanical Engineering, Kookmin University)
  • 한도영 (국민대학교 기계 자동차공학부) ;
  • 박관준 (국민대학교 대학원 기계공학과)
  • Published : 2006.02.01

Abstract

In order to control multi-zone temperatures, a multi-type air-conditioning system may be used. In this study, control algorithms for the compressor and the electronic expansion valve of a multi-type air-conditioning system were developed by using fuzzy logics. The compressor control algorithm was composed of a compressor pressure setpoint algorithm, a compressor pressure setpoint reset algorithm, and a compressor frequency setpoint algorithm. The electronic expansion valve control algorithm was composed of an indoor temperature control algorithm, and a superheat control algorithm. These algorithms were applied to a multi-type air-conditioning system. Test showed good results for the control of a multi-type air-conditioning system.

Keywords

References

  1. Kwon, Y. C., Ko, K. W., Jin, E. S., Huh, S. H., Jun, Y. H., Lee, Y. D. and Park, I. K., 2004, Experimental study on cooling characteristics of multi-air conditioner using inverter scroll compressor, SAREK, Vol. 16, No. 4, pp. 311-317
  2. Rice, C. K. and Fisher, S. K., 1985, A comparative analysis of single and continuously variable-capacity heat pump concepts, Proc. of the DOE/ORNL Heat Pump Conference, pp.57-65
  3. Han, D. and Park, K. J., 2001, Performance analysis of the tandem-type multi heat pump system, Proceedings of the SAREK, pp. 15-20
  4. Kim, S. Y. and Kim, M. S., 2001, Capacity modulation of a multi-heat pump system using PID control with fuzzy logic, SAREK, Vol. 13, No. 9, pp. 810-817
  5. Choi, J. M., Kim, Y. C. and Ha, J. H., 2001, Experimental study on superheat control of a variable speed heat pump, SAREK, Vol. 13, No. 4, pp. 233-241
  6. Han, D. and Yoo, P. S., 2001, Seasonal performance analysis of the EXV used heat pump system, Proceedings of the SAREK, pp. 841-846
  7. Han, D. and Lee, S. W., 2002, Zone temperature control of the multi-type air-conditioning system using EEV super-heat control algorithms, Proceedings of the SAREK, pp. 357 -362
  8. Han, D. and Lee, S. W., 2003, The EEV control of the multi-type air-conditioning system by using a fuzzy logic superheat temperature setpoint reset algorithm, SAREK, Vol. 15, No. 5, pp. 382-388
  9. Han, D. and Kwon, H. J., 2000, Compressor speed control of the multi-type air conditioning system by using a fuzzy algorithm, . Proceedings of the SAREK, pp. 1348-1352
  10. Room Air-Conditioners, 1999, KSC 9306, Korean Standard Association