Fast Defect Detection of PCB using Ultrasound Thermography

초음파 서모그라피를 이용한 빠른 PCB 결함 검출

  • Published : 2006.02.01

Abstract

Active thermography has been used for several years in the field of remote non-destructive testing. It provides thermal images for remote detection and imaging of damages. Also, it is based on propagation and reflection of thermal waves which are launched from the surface into the inspected component by absorption of modulated radiation. For energy deposition, it use external heat sources (e.g., halogen lamp or convective heating) or internal heat generation (e.g., microwaves, eddy current, or elastic wave). Among the external heat sources, the ultrasound is generally used for energy deposition because of defect selective heating up. The heat source generating a thermal wave is provided by the defect itself due to the attenuation of amplitude modulated ultrasound. A defect causes locally enhanced losses and consequently selective heating up. Therefore amplitude modulation of the injected ultrasonic wave turns a defect into a thermal wave transmitter whose signal is detected at the surface by thermal infrared camera. This way ultrasound thermography(UT) allows for selective defect detection which enhances the probability of defect detection in the presence of complicated intact structures. In this paper the applicability of UT for fast defect detection is described. Examples are presented showing the detection of defects in PCB material. Measurements are performed on various kinds of typical defects in PCB materials (both Cu metal and non-metal epoxy). The obtained thermal image reveals area of defect in row of thick epoxy material and PCB.

Keywords

References

  1. A. Dillenz, T. Zweschper, G. Riegert, and G. Busse, 'Progress in phase angle thermography', Review of Scientific Instruments, Vol. 74, No. 1, p. 417, 2003 https://doi.org/10.1063/1.1524010
  2. G. Busse, 'Optoacoustic phase angle measurement for probing a metal', Appl. Phys. Lett. Vol. 35, p. 759, 1979 https://doi.org/10.1063/1.90960
  3. D. Wu, A. Salerno, U. Malter, and G. Busse, 'Inspection of aircraft structural components usinglock-in thermography', Quantitative Infrared Thermography, p. 251, 1997
  4. Th. Zweschper, A. Dillenz, and G. Busse, 'Inspection of aerospace structures with ultrasound lock-in-Thermography', http://www.ndt.net/article/wcndt00/papers/idn312/
  5. G. Lutz, 'Inspection of copper canisters for spent nuclear fuel by means of ultrasound', Technical Reports TR-04-03, 2004
  6. A. Dillenz, G. Busse, and D. Wu, 'Ultrasound lockin thermography: feasibilities and limitations', Proc. SPIE Vol. 3827, p. 10, 1999 https://doi.org/10.1117/12.361008
  7. http://ulsso.com/index1.html