The Assessment of Survey on the Indoor Air Quality at Schools in Korea

국내 일부학교 건축물의 실내공기질 평가

  • Sohn Jong-Ryeul (Department of Environmental Health, Korea University) ;
  • Roh Young-Man (Department of Occupational & Environmental Medicine, Hanyang University) ;
  • Son Bu-Soon (Department of Environmental Health Science, Soonchunyang University)
  • 손종렬 (고려대학교 보건과학대학 환경보건학과) ;
  • 노영만 (한양대학교 환경 및 산업의학연구소) ;
  • 손부순 (순천향대학교 환경보건학과)
  • Published : 2006.04.01

Abstract

Recently, indoor air quality (IAQ) in workplace, residential environments and schools has been concerned of people, scientists and related the public, and has recognized the health effects related to indoor air pollution. Therefore, this study was performed to investigate the characteristics of IAQ in 55 kindergartens, elementary school, middle schools, and high schools from June, 2004 to May, 2005 in Korea. We measured indoor air pollutants($PM_{10},\;CO_2$, HCHO, total bacteria colony(TBC), CO, radon, TVOCs, asbestos, and $O_3$), and physical factors(noise, temperature, relative humidity, and illumination) with necessary of management for IAQ in school. We classified into 5 kinds of the school by period since building completion, <1 year, 1-3 years, 3-5 years, and 5-10 years. The concentration of pollutants and the level of physical factors compared with standards and guidelines of IAQ on the Ministry of Environment, the Ministry of Health and Welfare, and the Ministry of Education and Human Resources Development. The major results obtained from this study were as follows. Temperature, relative humidity and illumination among the physical factors did not exceed the standards, but noise exceeded it. Asbestos and $O_3$ did not detect in surveyed classrooms. CO, TBC, TVOCs, and HCHO in kindergartens, TBC in elementary schools, TBC, TVOCs dnd HCHO in middle schools, and HCHO in high schools detected the standards. This study is conducted as a part of efforts to provide a foundational data for further relative researches on management of IAQ of school. Therefore, we suggest that country plan for management of IAQ in school should be established through long-term and continuous investigation for assessment on IAQ in school and health risk assessment for students.

Keywords

References

  1. Stolwijk, J. A. : Risk assessment of acute health and comfort effects of indoor air pollution. Annals of the New York Academy of Sciences, 641, 56-62, 1992 https://doi.org/10.1111/j.1749-6632.1992.tb16532.x
  2. National Academy of Sciences(NAS), Human exposure assessment for airborne pollutants, Washington DC. 1993
  3. 김성신 : 신축소규모 아파트의 겨울철 실내공기환경. 한국생활환경학회 춘계학술지. 54-55, 1997
  4. 김미경 : 실내 포름알데히드 농도에 관한 연구조사. 한국환경위생학회지, 15(2), 1-9, 1989
  5. Lee, S. C. and M. Chang, L. Y. : Indoor air and outdoor air quality investigation at schools in Hong Kong, Chemosphere. 109-113, 2000
  6. 교육인적자원부, 학교보건법 시행규칙, 2005
  7. 이주상, 원정일, 이철민, 김윤신 : 노래방과 컴퓨터 게임방 내의 실내공기오염에 관한 연구. 대한위생학회지, 17(3), 67-74, 2002
  8. 김윤신 : 실내공기오염. 대한의학학회지, 32(12), 1279-1285, 1989
  9. 백남원 : 학교환경. 한국학교보건학회지, 4(2), 31-41, 1991
  10. 서울시교육청. 쾌적한교실환경만들기, 2003
  11. 정영숙, 이정렬 : 학교보건, 수문사. 23-28. 2000
  12. 남철현, 정기혜 : 중.고등학교 학생들의 환경보건에 대한 지식 태도 조사. 한국환경위생학회지, 23(3), 7-26, 1997
  13. 교육인적자원부. 학교보건 및 교내 환경위생 개선방안에 관한 연구보고서. 2000
  14. 김윤신, 이철민, 문정숙, 김상욱 : 서울.경기지역 초.중.고등학교 교실의 실내공기오염에 관한 연구. 한국학교보건학회지, 16(1), 81-90, 2003
  15. 김순애, 백남원 : 도시 일부지역에서의 실내 라돈농도에 관한 연구. 한국환경위생학회지, 28(2), 703-712, 2002
  16. 남보현, 황인조, 김동술 : 분산주성분 분석을 이용한 실내환경 중 PM-10 오염의 패턴분류. 한국대기환경학회지, 18(1), 25-37, 2002
  17. 보건복지부, 공중위생법 공중이용시설 위생관리기준, 1990
  18. 환경부, 실내공기질공정시험방법, 환경부 고시 제2004-80호(2004.6), 2004
  19. 손종렬 : 실내공기와 건강, 한국실내산소연구회, 2004
  20. 신동천, 이효민, 김종만, 정 용 : 일부지역의 실내공기 오염도와 건강에 미치는 영향에 관한 연구. 한국대기보전학회지, 6(1), 73-84, 1990
  21. Richard, A.W. and Peter, A.S. : Indoor air pollution, A Wiley-Interscience Publication, 1983
  22. 이철민, 김윤신, 박원석, Takao Iida : 주요 5개 도시의 실내외 라돈농도 조사연구. 대한위생학회지, 17(3), 75-82, 2002