A Study on the Strategy to Maintain Optimal Flow-rate and Pressure of the Piping System for Individual Heating

개별 난방방식에서의 배관 내 절정 유량 및 압력유지에 관한 연구

  • Published : 2006.04.01

Abstract

For the more comfortable thermal environment in residential buildings, it was necessary for variable components like as automatic flow limiting valves and/or balancing valves in hydronic system. And, these components had an effect on flow-rate and pressure inside pipe. In this case, the incompatibility between the design for the heating system and the selection of equipment was the causes of several problems in heating pipe network. In this study, we peformed measurements and analyses of flow rate and pressure inside pipe for radiant floor heating in residential buildings through field surveys and experiments in order to find out the actual conditions and problems. On the basis of this, we suggested the approach for the optimal flow-rate and pressure maintaining inside pipe in individual heating system.

Keywords

References

  1. 김오봉.오주환.여명석.김광우(2004), 바닥복사 난방에서 유량밸런싱을 통한 실별 제어시스템의 열성능, 설비공학회 하계학술발표대회 논문집, pp. 1127-1131
  2. 김오봉.이미경.여명석.김광우(2004), 공동주택에서 바닥복사 난방시스템의 실별 제어에 관한 연구, 설비공학회논문집, 16권 5호, pp. 421-429
  3. 여명석.김광우(1999), 공동주택 온수온돌 바닥복사 난방시스템의 제어방법에 관한 연구, 대한건축학회 논문집, 15권 3호, pp. 119-117
  4. 여명석.석호태.김광우(1998), 공동주택 온수온돌 바닥복사 난방시스템의 온수온도 제어방법에 관한 연구, 대한건축학회 논문집, 14권 12호, pp. 203-210
  5. 조영흠.김오봉.여명석.김광우(2002), 공동주택 현장실험을 통한 존별제어시스템의 열성능에 관한 연구, 대한건축학회 추계학술발표대회 논문집(계획계), 22권 2호 pp. 773-776
  6. 홍석진.류성룡.여명석.김광우(2004), 복사난방시스템의 적정 유량분배 방안에 관한 연구, 생활환경학회 논문집, 11권 3호. DO. 153-159
  7. ASHRAE(2001), 2001 ASHRAE Handbook-Fundamentals. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc
  8. E. Hansenl(2001), Hydronic System Design & Operationok, McGraw-Hill Book Company
  9. F. Golestan(1996), Automatic Balancing Valve in Distribution networks today, ASHRAE Transaction, 102(2), pp. 439-444
  10. Flowmaster International Ltd(2004,), Flowmaster Program Manual, Flowmaster International Ltd
  11. J. Rishel(2003), Control of Variable Speed Pumps for HVAC Water Systems, ASHRAE Transaction, 109(1), pp. 380-389
  12. J. Rishel(2001), HVAC Pump Handbook Design, McGraw-Hill Book Company
  13. J. Siegenthaler(200l), Modem Hydronic heating for Residential and Light Commercial Building, Thomson Delmar Learning
  14. R. Ahlgren(1998), Selection of Hydronic Balancing Valves, ASHRAE Transaction, 104(1), pp. 1630-1635
  15. Ryu, S. R., Lim, J. H., Yeo, M. S., Kim, K. W.(2004), A Study on the Control Methods for Radiant Floor Heating and Cooling System in Residential Building. ASHRAE Transaction, 110(2), pp. 106-116