Abstract

In this research, IAQ is measured to evaluate the emission performance of VOCs in three new apartment houses finished by totally EFMs (Environmental Friendly Material), partially installed EFMs and general materials. Among various VOCs, Target pollutants for the IAQ measurement are benzene, ethylbenzene, toluene, xylene, 1,4-Dichlorobenzene and formaldehyde. The measurement is conducted one day after each interior finishing material is worked over by construction schedule. The result of this research concluded that (1) Except toluene, the concentration levels of each pollutant did not exceed the national IAQ standards in all test residences, (2) As the interior finishing work schedule, A toluene level peaked when the furniture installing was ended. (3) The toluene concentration level of the house installed general interior materials as the non-EFMs furniture was one and half higher than other houses. Consequently, installing. the furniture made by EFMs is one of effective methods to improve the IAQ for new apartment houses.

Keywords

References

  1. Sung, M. K., Min, Y. S., Lee, J. M. and Lee, S. M., 2005, Evaluation of building materials emission rates in newly built apartments, Proceeding of Annual Conference in AlK, Vol. 25, No. 1, pp.91-94
  2. Kim, H. W., Lee, K. H. and Sohn, J. Y., 2003, A study in the emitting characteristic of pollutant 'by finishing materials, Proceeding of Annual Conference in AlK, Vol. 23, No. 2, pp.813-817
  3. Kwak, M. J., Jo, W. J., Pang, S. K. and Sohn, J. Y., 2005, The impact of bake-out method on the reduction of pollutant concentration, Proceeding of Annual Conference in AlK, Vol. 25, No.1, pp.411-414
  4. Pang, S. K., Sohn, J. Y. and Ahn, B. W., 2005, Prediction of the concentration decay of volatile organic compounds under different air change rates and loading factor conditions, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 6, pp. 505-513
  5. Pang, S. K., Sohn, J. Y. and Park, B. Y., 2005, Prediction of concentration decay of VOCs emitted from Ondol floor and furniture, Journal of the Architectural Institute of Korea, Vol. 21, No.6, pp. 125-132
  6. Spengler, J. D. Samet, J. M. and McCarthy, J. F., 2001, Indoor Air Quality Handbook, MeGraw-Hill, p. 315
  7. Keith, L. H. and Warker, M. M., 1995, Handbook of Air Toxics: Sampling, Analysis, and Properties, Lewis Publisher, Inc
  8. Samet, J. M. and Spengler, J. D., 1991, Indoor Air Pollution, The Johns Hopkins University Press, Baltimore, pp. 252-272
  9. Rostron, J., 1997, Sick Building Syndrome, E&FN Spon, London, p. 39
  10. Salthammer, T., 1997, Emission of volatile organic compounds from furniture coatings, Indoor Air, Vol. 7, No. 3, pp.189-197 https://doi.org/10.1111/j.1600-0668.1997.t01-1-00004.x
  11. Van der Wal, J. F., Hoogeveen, A. W. and Wouda, P., 1997, The influence of temperature on the emission of volatile organic compounds from PVC flooring, carpet, and paint, Indoor Air, Vol. 7, No. 3, pp.215-221 https://doi.org/10.1111/j.1600-0668.1997.t01-1-00007.x
  12. Wolkoff, P., 1998, Impact of air velocity, temperature, humidity, and air on long-term VOC emissions from building products, Atmospheric Environment, Vol. 32, No. 14/15, pp.2659-2668 https://doi.org/10.1016/S1352-2310(97)00402-0