This study was conducted to understand the change of spatial environmental factors including populations, air pollution source and land-use in Busan, during the period of 1995 and 2004. Firstly, the grids (5 km $\times$ 5 km) were divided using the TM coordinates of Busan and the statistical data of populations and land-use were marked on each grid during studying period. Secondly, the SO$_2$, NO$_2$ and O$_3$ concentrations of areas where air quality monitoring station was not established were estimated on the basis of these air pollutants measured at close air quality monitoring station by kriging method. In order to understand spatial change of air pollution and to investigate duplication and reduction of existing stations, semivariogram, correlation and cluster analysis were carried out. This study showed that the population increased in 2004 only on 8 grids compared to in 1995. The spatial change of SO$_2$, NO$_2$ and O$_3$ was investigated by semivariogram in Busan area. As the results of semivariogram, the spatial change of 502 become smaller and simpler, while that of NO2,03 become larger and more complex in 2004 than in 1995, According to the result of correlation and cluster analysis, the reduction of measurement item or the relocation of air quality monitoring station can be needed in the high dense grid area.

Keywords

References

  1. 건설교통부.부산광역시.경상남도 (2005) 2020년 부산권 광역도시계획
  2. 부산광역시 홈페이지 통계자료실(2005) 부산광역시 통계연보, www.busan.go.kr
  3. 정장표(2000) 환경오염물질의 시.공간적 특성 평가시스템 개발, 2000년도 산.학.연 컨소시엄 연구개발보고서, 경성대학교 산.학.연 컴소시엄센터
  4. 환경부(2005) 대기오염측정망 기본계획(2006-2010)
  5. 환경부.국립환경연구원(2004) 대기환경연보
  6. Anh, V., M. Azzi, H. Duc, and G. Johnson (1996) Classification of air quality monitoring stations in the Sydney region, Proceeding of the asia-pacific confernece on sustainable energy and environmental technology, 264-271
  7. Duc, H., I. Shannon, and M. Azzi (2001) Spatial distribution characteristics of some air pollutants in Sydney, Mathematics and Computers in Simulation 54, 1-21 https://doi.org/10.1016/S0378-4754(00)00165-8
  8. Larsen, R.I., C.E. Zimmer, D.A. Lynn, and K.G. Blemel (1967) Analyzing air pollutant concentration and dosage data, J. APCA, 17(2), 85-93
  9. Matheron, G. (1963) Principles of geostatistics. Economicgeology 58, 1246-1266
  10. Sales, J.D., R.A. Smith, G.Q. Tabios III, and J.H. Heo (1994) Statistical Computer Techniques in Water Resources and Environmental Engineering, chaper 13
  11. Sen, Z. (1995) Regional air pollution assessment by cumulative semivariogram technique Atmos. Environ. 29, 543-548
  12. Sen, Z. (1989) Cumulative semivariogram models of regionalized variables, Mathematical Geology, 21(8), 891-903 https://doi.org/10.1007/BF00894454
  13. Yu, T.Y. and L.F.W. Chang (2001) Delineation of air-quality basins utilizing multivariate statistical methods in Taiwan, Atmospheric Environment, 35, 3155-3166 https://doi.org/10.1016/S1352-2310(00)00517-3