Estimation of Nonpoint Pollutant Removal Capacity in the Buffer Strip with AnnAGNPS Model

AnnAGNPS 모형을 이용한 수변구역의 비점오염물질 제거능 산정

  • Park, Yun Hee (Environmental Cap System Reach Department, NIER) ;
  • Kim, Tae Geun (Department of Environmental Engineering, Chongju University)
  • 박윤희 (국립환경과학원 환경총량관리연구부) ;
  • 김태근 (청주대학교 환경공학과)
  • Received : 2006.08.02
  • Accepted : 2006.10.21
  • Published : 2006.10.31

Abstract

AnnAGNPS model would be applied to simulate the pollutant removal capacity with the buffer strip in the Deachung reservoir watershed. In 2002, 2,270 tons of TN and 221 tons of TP were discharged from the nonpoint source pollutants in this watershed. During the rainy season, from June to September, 66.4% of TN and 71.9% of TP resulted from nonpoint source loads. AnnAGNPS model was also used to simulate the nutrients removal capacity from the buffer strip under the condition that the present landuse would be changed to forest. As the result of simulation, the removal rates of nutrients from the buffer strip of Daecheong reservoir watershed are 406 tons of TN, 39 tons of TP, which means reduction rates are TN 17.9%, TP 17.8%, respectively.

Keywords