Development of Y Strainer Type Automatic Flow Rate Regulating Valve

Y 스트레이너형 자동 정유량 조절 밸브의 개발

  • 윤준용 (한양대학교 기계정보경영공학부) ;
  • 권우철 (한양대학교 대학원 기계공학과)
  • Published : 2007.02.01

Abstract

An 'Y' strainer type automatic flow rate regulating valve, which functions are to remove impurities from hot water inside the pipe and to maintain a constant flow rate regardless of variations of the differential pressure between valve inlet and outlet at the same time, is developed for distributing hot water equally to several pipes with district heating or central heating system. Numerical analysis of the three dimensional turbulent flow field in a valve shape is carried out to confirm the flow field whether the designed regulator shape is acceptable or not. The final developed valve improves installation time and cost and maintenance ability comparing with set-up 'Y' strainer and regulator separately. Tolerance for the nominal flow rate is also satisfied within ${\pm}5%$.

Keywords

References

  1. 권우철, 이병휘, 2004, 'Y형 세대별 정유량 밸브 개발에서의 CFD의 활용,' 유체긱계공업학회 2004 유체기계 연구개발 발표회 논문집, pp. 488-491
  2. 한국산업규격, 'KS B 2304 - 밸브의 검사 통칙,' 한국표준협회
  3. 윤준용, 변성준, 양재모, 이도형, 2001, '고차압 제어용 글로브 밸브 트림 내부의 3차원 유동장 해석,' 유체기계저널, 제4권 제3호, pp. 14-20
  4. 고기창, 'Control Valve Handbook,' 한국본산(주), pp. 39-45
  5. Philip L. Skousen, 'Valve Handbook,' 2nd ed., McGraw-Hill, pp. 339-434