Scoliosis Correction with Thoracic Pedicle Screws: Posteroanterior C-arm Rotation Method

측만증 교정술에서 흉추경 나사못의 삽입 술기: 후전방 C형 투시 장치 회전 방법

Hwang, Chang-Ju;Ahn, Young-Joon;Kang, Seok-Joong;Kim, Ji-Hyo;Jeong, Kyeong-Il;Kim, Yung-Tae;Lee, Dong-Ho;Lee, Choon-Sung
황창주;안영준;강석중;김지효;정경일;김영태;이동호;이춘성

  • Published : 20070200

Abstract

Purpose : This study evaluated a practical, safe and accurate method of thoracic pedicle screw insertion for the surgical treatment of scoliosis using the posteroanterior C-arm fluoroscopy rotation method. Materials and Methods: A total of 611 thoracic pedicle screws were inserted in 45 patients using the posteroanterior (PA) C-arm rotation method. CT scans were taken postoperatively in the transverse and sagittal sections to evaluate the pedicle screw placement. Results : A mean preoperative curve of 57.7˚ was corrected to 17.1˚ (range, 3˚-45˚) in the coronal plane. The postoperative CT scans revealed that 10 screws (1.6%) had penetrated the medial cortex by a mean distance of 3.0 mm and 56 screws (9.2%) penetrated the lateral cortex by a mean distance of 3.5 mm. No screw penetrated the inferior or superior cortex in the sagittal plane. However, 21 screws (3.4%) penetrated the anterior cortex. No neurological or vascular complications were encountered, and none of the screws required replacement. Conclusion : Thoracic pedicle screw insertion in scoliosis patients using the posteroanterior C-arm rotation method is a practical, simple and safe technique that allows the en face visualization of both pedicles by rotating the C-arm to compensate for the rotational deformity.

목적: 후전방 C형 투시 장치 회전 방법을 이용한 척추 측만증의 수술적 치료에서 흉추 척추경 나사못 삽입의 실용적이고 안전하며 정확한 방법을 알아보고 소개하고자 하였다. 대상 및 방법: 한 명의 숙련된 척추외과 의사가 후전방 C형 투시 장치 회전 방법을 이용하여 45명의 흉추부 만곡이 주만곡인 측만증 환자에서 611개의 흉추 척추경 나사못을 삽입하였다. 흉추 척추경 나사못의 정확한 위치를 알기 위해 술후 컴퓨터 단층 촬영을 시행하였다. 결과: 삽입된 611개의 나사못 중 10개의 나사못(1.6%)이 내측 피질을 천공하였고, 56개의 나사못(9.2%)이 외측 피질을 천공하였다. 21개의 나사못(3.4%)이 추체의 전방 피질을 관통하였고, 시상면 상에서 척추경의 상하 피질을 천공한 경우는 없었다. 신경 혈관계의 합병증이나 나사못을 재삽입해야 하는 경우도 없었다. 결론: 척추 측만증 환자에서 후전방 C형 투시 장치 회전 방법을 이용한 흉추 척추경 나사못 삽입 방법은 회전 변형이 있는 추체에서 회전 변형에 맞춰 C형 투시 장치를 회전시켜 양측 척추경이 대칭으로 보이는 진성 전후면 영상에서 나사못을 삽입하기 때문에 배우기 쉽고, 간편하게 적용할 수 있으며, 안정성이 높은 방법이라고 판단된다.

Keywords

References

  1. Belmont PJ Jr, Klemme WR, Dhawan A, Polly DW Jr: In vivo accuracy of thoracic pedicle screws. Spine, 26: 2340-2346, 2001 https://doi.org/10.1097/00007632-200111010-00010
  2. Cinotti G, Gumina S, Ripani M, Postacchini F: Pedicle instrumentation in the thoracic spine. A morphometric and cadaveric study for placement of screws. Spine, 24: 114-119, 1999 https://doi.org/10.1097/00007632-199901150-00003
  3. Ebraheim NA, Jabaly G, Xu R, Yeasting RA: Anatomic relations of the thoracic pedicle to the adjacent neural structures. Spine, 22: 1553-1556, 1997 https://doi.org/10.1097/00007632-199707150-00002
  4. Foley KT, Simon DA, Rampersaud YR: Virtual fluoroscopy: computer-assisted fluoroscopic navigation. Spine, 26: 347-351, 2001 https://doi.org/10.1097/00007632-200102150-00009
  5. Gertzbein SD, Robbins SE: Accuracy of pedicular screw placement in vivo. Spine, 15: 11-14, 1990 https://doi.org/10.1097/00007632-199001000-00004
  6. Kim KD, Patrick Johnson J, Bloch BS O, Masciopinto JE: Computer-assisted thoracic pedicle screw placement: an in vitro feasibility study. Spine, 26: 360-364, 2001 https://doi.org/10.1097/00007632-200102150-00011
  7. Kim YJ, Lenke LG, Bridwell KH, Cho YS, Riew KD: Free hand pedicle screw placement in the thoracic spine: is it safe? Spine, 29: 333-342, 2004 https://doi.org/10.1097/01.BRS.0000109983.12113.9B
  8. Lenke LG, Rinella A, Kim YJ: Freehand throacic pedicle screw placement. Seminars in Spine Surgery, 14:48-57, 2002
  9. Liljenqvist UR, Allkemper T, Hackenberg L, link TM, Steinbeck J, Halm HF: Analysis of vertebral morphology in idiopathic scoliosis with use of magnetic resonance imaging and multiplanar reconstruction. J Bone Joint Surg Am, 84: 359-368, 2002
  10. Liljenqvist U, Hackenberg L, Link T, Halm H: Pullout strength of pedicle screws versus pedicle and laminar hooks in the thoracic spine. Acta Orthop Belg, 67: 157-163, 2001
  11. Liljenqvist UR, Halm HF, Link TM: Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis. Spine, 22: 2239-2245, 1997 https://doi.org/10.1097/00007632-199710010-00008
  12. Liljenqvist U, Lepsien U, Hackenberg L, Niemeyer T, Halm H: Comparative analysis of pedicle screw and hook instrumentation in posterior correction and fusion of idiopathic thoracic scoliosis, Eur Spine J, 11: 336-343, 2002 https://doi.org/10.1007/s00586-002-0415-9
  13. Liljenqvist UR, Link TM, Halm HF: Morphometric analysis of thoracic and lumbar vertebrae in idiopathic scoliosis. Spine, 25: 1247-1253, 2000 https://doi.org/10.1097/00007632-200005150-00008
  14. Mirza SK, Wiggins GC, Kuntz C 4th, et al: Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: a cadaver study. Spine, 28: 402-413, 2003 https://doi.org/10.1097/00007632-200302150-00018
  15. O'Brien MF, Lenke LG, Mardjetko S, et al: Pedicle morphology in thoracic adolescent idiopathic scoliosis: is pedicle fixation an anatomically viable technique? Spine, 25: 2285-2293, 2000 https://doi.org/10.1097/00007632-200009150-00005
  16. Rampersaud YR: Advanced image guidance for the placement of thoracic pedicle screws. Seminars in Spine Surgery, 14: 58-65, 2002
  17. Suk SI, Kim WJ, Lee SM, Kim JH, Chung ER: Thoracic pedicle screw fixation in spinal deformities: are they really safe? Spine, 26: 2049-2057, 2001 https://doi.org/10.1097/00007632-200109150-00022
  18. Vaccaro AR, Rizzolo SJ, Balderston RA, et al: Placement of pedicle screws in the thoracic spine. Part II: An anatomical and radiographic assessment, J Bone Joint Surg Am, 77: 1200-1206, 1995 https://doi.org/10.2106/00004623-199508000-00009
  19. Xu R, Ebraheim NA, Ou Y, Yeasting RA: Anatomic considerations of pedicle screw placement in the thoracic spine. Roy-Camille technique versus open-lamina technique. Spine, 23: 1065-1068, 1998 https://doi.org/10.1097/00007632-199805010-00021
  20. Youkilis AS, Quint DJ, McGillicuddy JE, Papadopoulos SM: Stereotactic navigation for placement of pedicle screws in the thoracic spine. Neurosurgery, 48: 771-778, 2001 https://doi.org/10.1097/00006123-200104000-00015
  21. Zindrick MR, Wiltse LL, Widell EH, et al: A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop Relat Res, 203: 99-112, 1986