Vertical Flow Zeolite-Filled Reed Bed with Intermittent Feeding for Sewage Treatment

수직 흐름 제올라이트 갈대 여과상에 의한 생활하수 처리

  • Seo, Jeoung-Yoon (Department of Environmental Engineering, College of Engineering, Changwon National University)
  • 서정윤 (창원대학교 환경공학과)
  • Published : 2007.04.30

Abstract

A sewage was treated using a vertical flow zeolite-filled reed bed. The sewage from the student dormitory of Changwon National University was fed into the reed bed for 10 minutes every 6 hours at the hydraulic load of $314L/m^3{\cdot}$day. The filtering height of the reed bed was 100 em and the zeolite mixture was filled in the reed bed. The mixture consisted of the same volume of two types of zeolite: 0.5$\sim$1 mm and 1$\sim$3 mm in diameter. Annual average removal efficiency was 88 89.9%, $COD_{Cr}$ 86.1 %, $COD_{Mn}$ 81.2%, T-N 34.0%, $NH_4^+$-N 97.3% and T-P 34.6%. T-N of effluent was mostly $NO_3^-$-N and the concentration of $NO_2^-$-N in effluent was lower than 0.1 mg/L. All removal efficiencies did not show a remarkable seasonal change. The ranking of phosphorous fractions fixed to the zeolite in column test was Ca-P > Fe-P > reductant soluble Fe-P > occluded P > saloid P > AI-P at all depths of the filter. All phosphorous fractions except for AI-P reduced at deeper filter layer, while their content ratios increased at deeper filter layer. Organic matter content was the highest at the highest layer (0$\sim$5 cm from the top of the filter) and only small differences were observed at the deeper filter layer than 5 em from the top. Organic matter content increased at all depths of the filter with the operating time.

제올라이트로 충진된 수직 흐름 갈대 여과상에 인공하수를 주입하면서 처리효율을 조사하였다. 여과상 표면적 $m^2$당 1일 314 L의 인공하수가 6시간마다 10분 동안 간헐적으로 주입되었다. 처리수의 pH는 원수보다 감소하였으며, 용존산소 농도는 원수보다 증가하였다. 수직 흐름 여과상에서 각 항목별 연중 평균 처리효율은 SS 89.9%, $COD_{Cr}$ 86.1%, $COD_{Mn}$ 81.2%, BOD 93.3%, T-N 34.0%, $NH_4^+$-N, 97.3%,T-P 34.6%이었다. 처리수 중 T-N의 대부분은 $NO_3^-$-N이었으며 $NO_2^-$-N의 농도는 0.10 mg/L 이하이었다. 처리효율의 계절적 차이는 없었다. 수직 흐름 칼럼실험에서 여재인 제올라이트에 흡착된 인의 형태별 함량은 모든 깊이에서 Ca-P > Fe-P > 환원가용성 Fe-P > Occluded p > Saloid P > Al-P 순이었다. 여과상 깊이별 Al-P를 제외한 모든 종류의 인화합물의 함량은 위층일수록 높았으며, 함량 비율은 깊이가 깊을수록 높아지는 경향이었다. 유기물 함량도 상층 (0$\sim$5 cm 깊이)에 가장 높았으며, 그 이하의 깊이에서는 별 변화가 없었다. 가동기간이 경과할수록 모든 깊이에서 유기물 함량이 증가하였다.

Keywords

References

  1. An, T. -S, (1997), On the artificial wetland for water quality improvement in golf course, In Research Bulletin, Yongkang Foundation, 345-372
  2. Kim, Y., D. -S. Kim, S. -B. Jang, and S. -Y. Park (1996), Studies on the removal of metal ions with domestic Pohang zeolite and synthetic zeolite, J. KSEE 18(5), 587-589
  3. Yoo, S.-U. et al. (1997), Process development for simultaneous removal of nitrogen and phosphorus using natural zeolite, Institute of Samsung Mulsan Construction, Ministry of Environment, Korea
  4. Noh, J. H. and K. U. Kim (1988), Diagenetic alteration of tertiary formation in Kimpo Area, J. Geol. Soc. Korea 24(4), 397-416
  5. Noh, J. H. and J. R. Boles (1989), Diagenetic alteration of Perlite in Guryongpo area, Republic of Korea, Clays Clay Miner 37(1), 47-58 https://doi.org/10.1346/CCMN.1989.0370106
  6. Lee, J. -H., H. -U. Nam, Y. -G. Kim, and T. -J. Park (1998), Characteristics of phosphorus removal from municipal wastewater treatment using a combined fixed film reactor (CFFR) process, J. KSWQ 14(2), 129-135
  7. Hegemann, W. (1997), Abwasserentsorgung im Duenn besiedelten Flaechenland Brandenburg, Arch. fuer Nat.-Land.-, 00, 1-12
  8. Hegemann, W. (1996), Neue Entwicklung in der Klaertechnik Hightech und oder Einfachverfalrren, TU International, Nr. 34/35, 18-20
  9. Alder, P. R., S. T. Summerfelt, D. M. Glenn, and F. Takeda (1996), Evaluation of a wetland system designed to meet stringent phosphorus discharge requirement, Water Environment Research 68(5), 836-840 https://doi.org/10.2175/106143096X127839
  10. Seidel, K. (1967), Ueber die Selbstreinigung natuerlicher Gewaesser, Noturwissenschoft 63, 286-291
  11. Seo, J. - Y. (2002), Treatment of artificial sewage using a zeolite column, Korean Journal of Environmental Agriculture 21(3), 178-188 https://doi.org/10.5338/KJEA.2002.21.3.178
  12. Seo, J. -Y., T. -H. Kim, and M. S. Choi (2003), Vertical flow zeolite- filled reed bed for treatment of artificial sewage with intermittent feeding, Kor. J. Biotechnol. Bioeng. 18(2), 140-144
  13. Seo, J. -Y. and M. S. Choi (2003), Horizontal flow zeolite-filled reed bed for treatment of artificial sewage with intermittent feeding, Kor. J. Biotechnol. Bioeng. 18(6), 506-510
  14. Dongwha Teclmology (1999), Korea Standard Methods for the Examination of Waste and Wastewater
  15. Standard Methods for the Examination of Water and Wastewater, 18th Ed., APHA, AWWA, WPCF
  16. National Institute of Agricultural Science and Technology, Rural Development Administration, (1988) Chemical Analysis of Soil
  17. Park, C. S., S. G. Chung, G. M. Han, M. H. Song, Y. B. Chun, Y. G. Choi, J. H. Chung, C. N. Ok, S. U. Jang, J. G. Chung, J. B. Shin, M. Y. Lee, and D. M. Lee (1996), Soil Test Methods, aeron
  18. Chung, D. Y. et al. (2002), Development of an environmentally friendly sewage treatment model with water plant and sand for small communities, Ministry of Enviromnent(final report), Korea
  19. Kraft, H. ( 1987), Pflanzenklaeranlagen aus Oekologischer Sicht, ATV-Fortbildungskurs E/5, 18. 20.3.1987 in Fulda, Abwasserbeseitung in Laendlichem Raum
  20. Wissing, F. (1995), Wasserreinigung mit Pflanzen, E. U., Verlag Eugen Ulmer
  21. ATV-Regelwerk Abwassrer-Abfall (1989), Behandlung von hauelichem Abwasser in Pflanzen-beeten, ATV-Hinweisblatt H 262, Gesellschaft zur Foedenmg der Abwassertechnik e.V
  22. Seo, J. -V. and E. H. Kim (2006), Horizontal flow zeolite-filled reed bed for sewage treatment with intermittent feeding, Kor. J. Biotechnol. Bioeng. 18(6), 506-510
  23. Hammer, M. J. (1977), Water and Wastewater Technology, SI Version, John Wiley & Sons Co
  24. Platzer, C. (1997), Entwicklung eines Bemessungsansatzes zur Stickstoffelimination in Pflanzenklaeranlagen, Berichte zur Siedlungswasserwirtschaft Nr. 6, Doctorial dissertation of Technical University Berlin
  25. Bahlo, K. (1997), Reinigungsleisnmg und Bemessung von vertikal durchstroemten Bodenfiltem mit Abwasserrezirkulation', Fachbereich Bauingenieur- und Vennessungswesen der Universitaet Hannover, doctorial dissertation
  26. Fehr, G. and Schuette, H. (1990), Leistungsfaehigkeit intermittirend beschickter, bepflanzter Bodenfilter, 21. Wassertechnische Seminar, Pflanzenklaeranlagen - Besser Als Ihr Ruf? , Institut fuer Wasserversorgung, Abwasserbeseitigung und Raumplanung der Technischen Hochschule Darmstadt, 197-225