Effects of Operating Parameters on Cooling Performance of a Transcritical $CO_2$ Mobile Air-Conditioning System

운전조건 변화가 $CO_2$ 자동차 에어컨 시스템의 냉방성능에 미치는 영향에 대한 실험적 연구

  • Lee, Jun-Kyoung (School of Mechanical Engineering and Automation, Kyungnam University)
  • 이준경 (경남대학교 기계자동화공학부)
  • Published : 2007.07.01

Abstract

This paper deals with the research for the effects of the operating parameters that could be used for a transcritical $CO_2$ mobile air-conditioning system on the cooling performance. The experimental conditions of the performance tests for a system and components such as a gas cooler and an evaporator were suggested to compare the performance of each with the standardized test conditions. And this research presents experimental results for the performance characteristics of a $CO_2$ mobile air conditioning system with various operating conditions such as different gas cooler inlet pressures and frontal air velocities/temperatures passing through an evaporator and a gas cooler. Experimental results show that the cooling capacity was more than 5kW and coefficient of performance (COP) was more than 2.1, also. Therefore, we checked that the mobile air-conditioning system using $CO_2$ has good performance compared to that using HFC-134a.

Keywords

References

  1. G. Lorentzen, 'The Use of Natural Refrigerants: A Complete Solution to the CFC/HCFC Predicament,' Int. J. Refrig., Vol.18, No.3, pp.190-197, 1995 https://doi.org/10.1016/0140-7007(94)00001-E
  2. J. Petternsen, 'An Efficient New Automobile Air-Conditioning System based on $CO_2$ Vapor Compression,' ASHRAE Transactions, Symposia, pp.657-665, 1994
  3. K. F. Steven, 'Total Environmental Warming Impact (TEWI) Calculations for Alternative Automotive Air-Conditioning Systems,' SAE 970526, 1997
  4. M. H. Kim, J. Pettersen and C. W. Bullard, 'Fundamental Process and System Design Issues in $CO_2$ Vapor Compression Systems,' Progress in Energy and Combustion Science, Vol.30, pp.119-174, 2004 https://doi.org/10.1016/j.pecs.2003.09.002
  5. J. Petternsen, A. Hafner, G. Skaugen and H. Rekstad, 'Development of Compact Heat Exchangers for $CO_2$ Air-Conditioning Systems,' Int. J. Refrigeration, Vol.21, No.3, pp.180-193, 1998 https://doi.org/10.1016/S0140-7007(98)00013-9
  6. R. P. McEnaney, Y. C. Park, J. M. Yin and P. S. Hrnjak, 'Performance of the Prototype of a Transcritical R744 Mobile A/C System,' SAE 1999-01-0872, 1999
  7. Y. C. Park, J. M. Yin, C. W. Bullard and P. S. Hrnjak, 'Experimental and Model Analysis of Control and Operating Parameters of Transcritical $CO_2$ Mobile A/C System,' VTMS-4 Conference, London, England, pp.163-170, 1999
  8. J. P. Won, Y. S. Kim, H. K. Lee and D. H. Lee, 'Experimental Study on the Performance Characteristics of the Mobile Air-conditioning System Using a $CO_2$ Refrigerant,' Fall Conference Proceedings, Vol.I, KSAE, pp.433-439, 2004
  9. J. K. Lee, D. H. Lee, H. K. Lee and J. P. Won, 'Development of Optimum High Pressure Algorithm for a Transcritical $CO_2$ Mobile Air-Conditioning System,' Spring Conference Proceedings, Vol.IV, KSAE, pp.2453-2459, 2006
  10. D. Han and K. Jang, 'Dynamic Models and Intelligent Control Algorithms for a $CO_2$ Automotive Air Conditioning System,' Transactions of KSAE, Vol.14, No.4, pp.49-58, 2006