DOI QR코드

DOI QR Code

Relationship between Office Residents' Activities and Concentration Distribution of Particulate Contaminants Distribution by Operation of Air Cleaner

공기정화기 가동에 따른 사무실 재실자들의 행동성과 입자상 오염물질의 농도 분포 관계에 관한 연구

  • Kim, Ki-Youn (Department of Preventive Medicine & Public Health, School of Medicine, Ajou University) ;
  • Park, Jae-Beom (Department of Preventive Medicine & Public Health, School of Medicine, Ajou University) ;
  • Kim, Chi-Nyon (Institute for Occupational Health, College of Medicine, Yonsei University) ;
  • Lee, Kyung-Jong (Department of Preventive Medicine & Public Health, School of Medicine, Ajou University)
  • 김기연 (아주대학교 의과대학 예방의학교실) ;
  • 박재범 (아주대학교 의과대학 예방의학교실) ;
  • 김치년 (연세대학교 의과대학 산업보건연구소) ;
  • 이경종 (아주대학교 의과대학 예방의학교실)
  • Published : 2007.08.30

Abstract

The reduction efficiency of air cleaner on particulate contaminants such as dust, airborne bacteria and fungi distributed in the office was relatively higher in case of office with workers than office without workers. This result would be attributed to workers' activities and physical characteristics of particulate contaminants. The air cleaner decreased a concentration of airborne bacteria more than airborne fungi, which implicates that difference of dust adsorption between airborne bacteria and fungi would affect an operation efficiency of air cleaner.

Keywords

References

  1. 노동부 : 산업안전보건법. 2003
  2. 노영만, 이철민, 김윤신, 김석원, 김치년, 김현욱, 조기홍, 최호춘, 김정만 : 건강위 해성평가에 의한 사무실 실내공기오염물질의 관리항목 확대. 한국산업위생학회지 1, 54-67, 2006
  3. 노영만, 이철민, 김윤신, 김석원, 김치년, 김현욱, 조기홍, 최호춘, 김정만 : 사무실 내 실내공기질 특성 및 근무자의 자각증상에 관한 연구. 한국산업위생학회지 14, 270-279, 2004
  4. 김기연, 김혜정, 김현수, 김치년, 원종욱, 노영만, 노재훈 : 석유화학공장 사무실 공기질과 근로자 자각 증상과의 연관성에 관한 연구. 한국실내환경학회지 3, 224-235, 2006
  5. 손종렬, 김영환, 우완기 : 실내용 공기청정기의 성능평가 및 인식도 조사. 대한위생학회지 17, 115-120, 2002
  6. 김용진 : 실내 공기청정기 인증을 위한 성능시험방법. 대한설비공학회지 33, 22-27, 2004
  7. 나경호, 손진석, 성기준, 장영기 : 실내용 공기청정기 유형별 실내환경개선 성능에 대한 비교평가. 환경영향평가 14, 109-115, 2005
  8. 정윤희, 홍준배, 장윤희 : 생활환경과 실내 공기의 미생물학적 오염에 관한 연구. 한국환경위생학회지 27, 1-9, 2001
  9. 이태형, 김윤신, 홍승철, 이철민, 김종철, 전형진, 김중호 : 공기청정기의 일부 실내공기 오염물질 제거효율에 관한 연구. 한국환경과학회지 14, 491-497, 2005 https://doi.org/10.5322/JES.2005.14.5.491
  10. Foarde, K. K., Hanley, J. T., Ensor, D. S. and Roessler, P. : Development of a method for measuring singlepass bioaerosol removal efficiencies of a room air cleaner. Aerosol Science and Technology 30, 223-234, 1999 https://doi.org/10.1080/027868299304804
  11. Tung, T. C. W., Niu, J. L., Burnett, J. and Hung, K. : Determination of ozone emission from a domestic air cleaner and decay parameters using environmental chamber tests. Indoor Built and Environment 14, 29-37, 2005 https://doi.org/10.1177/1420326X05049648
  12. 김기연, 김치년, 김윤신, 노영만, 이철민 : 복합식 공기청정기의 물리적 및 생물학적 입자상 물질의 제거 효과. 한국환경보건학회지 32, 478-484, 2006
  13. Donaldson, A. I. : Factors influencing the dispersal, survival and deposition of airborne pathogens of farm animals. Veterinary Bulletin 48, 83-94, 1978
  14. Robertson, J. H. and Frieben, W. R. : Microbial validation of ven filters. Biotechnology and Bioengineering 26, 828-835, 1984 https://doi.org/10.1002/bit.260260803
  15. Dales, R. E. H., Burnet, Z. R. and Freanklin, C. A. : Respiratory health effects of home dampness and mold among Children. American Journal of Epidemiology 134, 196-203, 1991 https://doi.org/10.1093/oxfordjournals.aje.a116072
  16. Anthony, K. Y., Chau, C. K. and Gilbert, Y. S. : Characteristics of bioaerosol profile in office in Hong Kong. Building and Environment 36, 527-541, 2001 https://doi.org/10.1016/S0360-1323(00)00020-2
  17. Otten, J. A. and Burge, H. A. : Bacteria. In: Macher, J. (Ed.), Bioaerosols, Assessment and control. ACGIH, Cincinnati, OH, pp. 200-214. 1999
  18. Pastuszka, J. S., Paw, U. K. T., Lis, D. O., Wlazlo, A. and Ulfig, K. : Bacterial and fungal aerosol in indoor environment in Upper Silesia, Poland. Atmospheric Environment 34, 3833-3842, 2000 https://doi.org/10.1016/S1352-2310(99)00527-0
  19. Grinshpun, S. A., Adhikari, A., Honda, T., Kim, K. Y., Toivola, M., Rao, K. S. R. and Reponen, T. : Control of aerosol contaminants in indoor air: combining the particle concentration reduction with microbial inactivation. Environmental Science and Technology 41, 606-612, 2007 https://doi.org/10.1021/es061373o