The Research of the HERO Test and Evaluation Technique

HERO 시험평가 기법 연구

  • Published : 2007.06.29

Abstract

This report presents the test technique using optic thermal sensor for the HERO evaluation of equipment installed EED. The calibration method of EED-thermal sensor assembly is explained by relation between the current in bridge wire and voltage in thermal sensor. And the HERO test and evaluation method is indicated based on MIL-STD-464A and MIL-STD-331C. The safety and reliability levels of EED-thermal sensor assembly are evaluated when exposed in the electromagnetic environment.

Keywords

References

  1. Jeffery D. Craven, Karen C. Compton, Electro magnetic Environmental Effects Criteria and Fuidelines for EMRH, EMRO, Lightning Effects, ESD, EMP, and EMI Testing of US Army Missile Systems, US Aemy Materiel Command, TR-RD-TE-97-01, Jan. 1997
  2. MIL-STD-1576 Valid Notice 1, Electroexplosive Subsystem Safety Requirements and Test Methods for Space Systems, Sep, 1992
  3. MIL-HDBK-1512, Electroexplosive Subsystems, Electrically Initiated, Design Requirements and Test Methods, Sep. 1997
  4. MIL-HDBK-240, Hazards of Electromagnetic Radiation to Ordnance(HERO) Test Guide, Nov. 2002
  5. MIL-STD-331C, Fuze and Fuze components, Environmental and performance tests for, Jan. 2005
  6. MIL-STD-464A, Electromagnetic Environmental Effects Requirements for Systems, Dec. 2002
  7. Frank P. Incropera, David P. De Witt, Fundamentals of Heat and Mass Transfer, John Wiley & Sons Inc, pp.43-50, 1985