Abstract

Tensile test results using three kinds of steel structure specimens are measured and compared. Slip coefficient between shot blasted steel plates was greater than 0.6. For the case of the plates coated with Super zinc, it revealed that the coefficients were greater than 0.5. On the other hand, Super epoxy coating decreased its slip coefficient less than 0.25. Steel plates coated with Super zinc are proved to be practically applicable to the steel structures with anti-corrosion characteristics and clean surfaces.

Keywords

References

  1. 박용명, 성택룡, '내후성강재 고장력볼트 이음부 미끄럼계수 평가 실험(I)', 대한토목학회논문집, Vol. 45, No. 2, pp. 455-459, 2002
  2. 삼성물산 건설부문, '건축기술지침 실무이야기', 공간예술사, 2001
  3. 대한건축학회, '건축기술지침-건축', 공간예술사, 2006
  4. 맹선재, 신명철, 정영훈, 이규찬, 현도빈, '재료시험', 한국과학기술연구소 재료시험연구실, 1980
  5. ASTM Standards, 'Standard Method for Tension Testing of Metallic Materials[Metric]', 1988