Analyses on Current Densities Induced Inside a Worker Using AC Arc Welder

교류 아크용접기를 사용하는 작업자의 인체 유도전류밀도 해석

  • 박준형 (순천향대학 전기통신시스템공학과) ;
  • 민석원 (순천향대학 전기통신시스템공학과)
  • Published : 2008.03.01

Abstract

This paper analyses current densities induced inside a worker using AC arc welder. Applying the boundary element method, we calculate current densities induced in organs inside a worker in case he was located at 1cm, 3cm, 5cm, 10cm, 15cm, 20cm far from a power cable of AC arc welder. As results of study, we find a maximum current density induces at a heart surface and may be higher than $10mA/m^2$ of ICNIRP guideline if he works within 15cm from a power cable.

Keywords

References

  1. P. A. Demers, D. B. Thomas, A. Sternhagen, W. D. Thompson, M. G. Curnen, W. Satariano, D. F. Austine, P. Issacson, R. S. Greenberg, C. Key, L. K. Kolonel, D. W. West, "Occupational exposure to electromagnetic fields and breast cancer in men," Am. J. Epidemiol., vol. 132, pp. 775-776, 1991.
  2. G. Theriault, M.Goldberg, A. B. Miller, B. Armstrong, P. Guenel, J. Deadman, E. Imbernon, T. To, A. Chevalier, D. Cyr, C. Wall, "Cancer risks associated with occupational exposure to magnetic fields among electric utility workers in Ontario and Quebec, Canada, and France-1970-1989," Am. J. Epidemiol., vol. 139, pp. 550-572, 1994. https://doi.org/10.1093/oxfordjournals.aje.a117046
  3. D. A. Savitz, D. P. Loomis, "Magnetic field exposure in relation to leukaemia and brain cancer mortality among electric utility workers," Am. J. Epidemiol., vol. 141, pp. 123-134, 1995. https://doi.org/10.1093/oxfordjournals.aje.a117400
  4. International Commission on Non-Ionizing Radiation Protection, "Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300GHz)," Health Phys., vol. 74, pp. 494-522, April 1998.
  5. 민석원, 송기현,"765kV 2회선 송전선 활선 작업자 인체 내부 유도전류 밀도 해석," 대한전기학회 논문지, vol. 55C, No. 5, pp. 231-238, 2005.
  6. 민석원, 박준형,"765kV 2회선 송전선 활선 작업자의 차 폐복 자계저감 특성검토," 대한전기학회 논문지, vol. 56, No. 9, pp. 1632-1637, 2006.
  7. M. A. Stuchly, D. W. Lecuyer, "Exposure to electromagnetic fields in arc welding," Health Phys., vol. 56, pp. 297-302, 1989. https://doi.org/10.1097/00004032-198903000-00003
  8. P. J. Dimbylow, "Induced current densities from low-frequency magnetic fields in a 2 mm resolution, anatomically realistic model of body," Phys. Med. Biol., vol. 43, pp. 221-230, 1998. https://doi.org/10.1088/0031-9155/43/2/001
  9. C. M. Furse, O. P. Gandhi, "Calculation of electric fields and currents induced in a millimeter resolution human model at 60 Hz using the FDTD method," Bioelectromagnetics, vol. 19, pp. 293-299, 1998. https://doi.org/10.1002/(SICI)1521-186X(1998)19:5<293::AID-BEM3>3.0.CO;2-X
  10. P. Baraton, J. Cahouet, B. Hutzler, "Three dimensional computation of the electric fields induced in a human body by magnetic fields," in Proc. of 8th Intern. Symposium on High Voltage Engineering 1993, pp. 517-520.
  11. O. Bottauscio, R. Conti, "Magnetically and electrically induced currents in human body models by ELF electromagnetic fields," in Proc. of 10th Intern. Symposium on High Voltage Engineering 1997, 5-8.
  12. K. Yamazaki, T. Kawamoto, H. Fujinami, T. Shigemitsu, "Investigation of ELF magnetically induced current inside human body development of estimation tools and effect of organ conductivity," Trans. IEE Japan, vol. 120-A, pp. 81-87, Jan. 2000.
  13. K. Yamazaki, T. Kawamoto, H. Fujinami, T. Shigemitsu, "Investigation of ELF magnetically induced current inside human body development of estimation tools and effect of organ conductivity," Trans. IEE Japan, vol. 120-A, pp. 81-87, Jan. 2000.